09.06.2017 Views

FAIRMONT HOTELS & RESORTS -DESIGN STANDARDS

Hotel Design

Hotel Design

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>FAIRMONT</strong> <strong>HOTELS</strong> & <strong>RESORTS</strong> · <strong>DESIGN</strong> <strong>STANDARDS</strong><br />

BACK-OF-HOUSE<br />

2.3. Primary Service Corridor<br />

Provide circulation for employees, goods and servicing. In the corridor servicing the<br />

ballroom, locate food service equipment in alcoves. Provide vestibule towards different<br />

ballroom access.<br />

Main service corridor to be a minimum of 8’0” (2.4 m) wide. Elsewhere, provide 6’6”<br />

(2.0 m) service corridor, except behind ballrooms (see ballroom standards for details).<br />

A double set of rubbing rails shall be installed in all service corridors, service elevators,<br />

service elevator foyers and vestibules. They shall be 2” wide x 6” high (5 x 15 cm) and<br />

installed at 9” (23 cm) at centerline AFFL and 2’11” (0.9 m) at centerline AFFL.<br />

2.4. Men’s and Women’s Locker Rooms<br />

Provide toilets, showers, wet vanity, grooming area and changing area with lockers for<br />

female and male employees; toilets should be separate from public toilets.<br />

Provide barrier-free WC stall as per local code requirements.<br />

Refer to specific program requirements to determine areas and quantities of lockers<br />

required.<br />

Unless otherwise indicated, female employees represent 60% of staff; male employees<br />

represent 40% of staff.<br />

Formula for calculating the locker area is (i) in cold climates is quantity of lockers x<br />

4.5 ft 2 – 0.4 m 2 ) and (ii) in warm climates is quantity of lockers x 3 ft 2 – 0.3m 2<br />

Should be located near Employee Entrance and Uniform issue.<br />

Provide janitor closet (approximately 36 ft 2 – 3.3 m 2 ).<br />

The lockers shall have sloping tops, infill pieces and bases.<br />

The rows between the lockers shall be 4’0” (1.2 m).<br />

Locker dimensions in (i) cold climates shall be 10” wide x 16” deep x 6’0” high – 03 x<br />

05 x 1.8 m (excluding base) and in (ii) warm climates they shall be 8” wide x 16” deep<br />

x 6’0” high – 20 cm x 0.5 m x 1.8 m (excluding base).<br />

One wall mounted notice board size 4’0” long x 3’0” high (1.2 m x 0.9 m).<br />

Duplex electrical outlet for shoeshine machine.<br />

Full-length mirror at entrance (on locker side) size 2’6” wide x 6’6” high (0.8 x 2 m)<br />

REV. MARCH 2006 156<br />

© 2002, Fairmont Hotels and Resorts. All Rights Reserved.