<strong>FAIRMONT</strong> <strong>HOTELS</strong> & <strong>RESORTS</strong> · <strong>DESIGN</strong> <strong>STANDARDS</strong><br />

BACK-OF-HOUSE<br />

Other Offices (continued)<br />

Mail Room to include the following features:<br />

a) A built in counter 2’0” wide and 3’0” (0.6 x 0.9 m) AFFL with<br />

adjustable shelving above and below counter<br />

b) One 220V single phase 30 <strong>amp</strong> outlet (separate circuit) for<br />

photocopier<br />

c) Three 110V 15 <strong>amp</strong> duplex outlets mounted 4’0” (1.2 m) to centre<br />

line AFFL (post meter, electric pencil sharpener)<br />

d) Two telephone outlets and two duplex electrical outlets (fax<br />

machines)<br />

e) Wall telephone.<br />

Telephone Operators Room to have the following features:<br />

a) A special two level built-in counter approximately 4’6” (1.4 m)<br />

long for three operators<br />

b) Duplex electrical outlet, telephone outlet and 1’6” (0.5 m) wide<br />

adjustable shelving at supervisor’s desk<br />

c) White marker board 6’0” wide x 4’0” high (1.8 x 1.2 m)<br />

d) Cork board 2’0” wide x 2’0” high (0.6 x 0.6 m)<br />

e) The lighting to this room must be on emergency power supply<br />

f) Each operator requires the following features:<br />

i) Duplex electrical outlet (UPS) and computer systems outlets<br />

(CRT and keyboard)<br />

ii) Two telephone outlets (console and paging telephone).<br />

The following must be located in the telephone operators’ room in full view of all the<br />

operators:<br />

a) Closed circuit TV monitors (slave security system)<br />

b) Remote door alarm indicator panel<br />

c) Cashier’s alarm indicator panel<br />

d) Walk-in coolers and freezers alarm indicator panel<br />

e) Fire alarm annunciation panel<br />

f) Smoke detector alarm annunciation panel.<br />

The following requirements are to be installed immediately above the telephone<br />

operators’ counter:<br />

REV. MARCH 2006 149<br />

© 2002, Fairmont Hotels and Resorts. All Rights Reserved.