09.06.2017 Views

FAIRMONT HOTELS & RESORTS -DESIGN STANDARDS

Hotel Design

Hotel Design

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>FAIRMONT</strong> <strong>HOTELS</strong> & <strong>RESORTS</strong> · <strong>DESIGN</strong> <strong>STANDARDS</strong><br />

BACK-OF-HOUSE<br />

1.5. General Requirements<br />

Each separate office group is to have one thermostat. Individual offices do not require<br />

thermostats.<br />

Each office area is to have a coat closet and general storage closet for everyday<br />

stationary supplies.<br />

Each individual office is to have three duplex electrical outlets, two telephone outlets<br />

and computer systems outlets as required by the LAN requirements.<br />

The offices of the Members of the Hotel’s Executive Committee are to have upgraded<br />

finishes and three telephone outlets, and additional duplex electrical outlet and<br />

computer outlets.<br />

Catering coordinators area to have a built in counter with a wall telephone outlet<br />

mounted 54” (137 cm) to centre line AFFL, duplex electrical outlets and computer<br />

outlets.<br />

All built in counters, shelves, cupboards, etc. to have velvetex finished plastic laminate<br />

finish with exposed hardwood edge strips.<br />

The following offices are to have all walls constructed to meet an FSTC rating of 54: (i)<br />

General Manager, (ii) Credit Manager, (iii) perimeter walls of washrooms where they<br />

are adjoining offices, (iv) perimeter walls of offices where they are adjoining public<br />

areas and (v) Director of Human Resources and interview room.<br />

Administration offices must have easy and direct access for the public. Front Desk<br />

Support should be adjacent to the Front Desk. Reception areas should be designed to<br />

reflect the elegance of Fairmont Hotels and Resorts as should senior management<br />

offices, especially that of the General Manager’s and Director of Catering. Accounting<br />

should be located in the back-of-the-house, to be accessible by Staff. Human Resources<br />

must be located near Staff Entrance and Security. Back-of-the-house spaces should have<br />

separate access away from public circulation.<br />

Secretarial positions must each have two telephone outlets and two duplex electrical<br />

outlets as well as two computer systems outlets for connection to LAN and printers.<br />

Offices with exterior windows must have incandescent lighting and special window<br />

treatment.<br />

Each office area is to have separate washrooms with vanity for male and female staff.<br />

In locations which are subject to frequent power outages, all duplex electrical outlets for<br />

administration assistants, secretaries and staff using computers must be on the<br />

uninterrupted power supply (UPS).<br />

VWC requires sealed drywall or smooth plaster as base construction to obtain<br />

acceptable finish.<br />

All exposed grilles, diffusers, sprinkler escutcheons, speakers, alarm bells, access<br />

panels, downlight trims, etc. required to be painted to match adjacent surface.<br />

REV. MARCH 2006 144<br />

© 2002, Fairmont Hotels and Resorts. All Rights Reserved.