GUESTROOM AREAS<br />

Water Closet (continued)<br />

2.15. Lanais and Terraces<br />

f) All fixtures will be products as manufactured by the Kohler<br />

Company or other equal and approved<br />

g) Ceiling exhaust grille with ductwork behind painted matt black<br />

h) Undercut door ¾” (20 mm) above threshold .<br />

a) Minimum clear width from door to railing to be 6’0” (1.8 m)<br />

b) Curved top balustrade rail should be as thin as possible to assure<br />

least possible obstruction of view. Open balustrade should be<br />

carried to floor with minimal upstand wall<br />

c) Weatherproof duplex electrical outlet<br />

d) Non-slip floor finish<br />

e) Brass floor drain<br />

f) Ceiling fan 4’0” (1.2 m) in diameter with variable speed control<br />

mounted 54” (1.5 m) to centre line AFFL in resorts<br />

g) Where the guestroom lanai or terrace has direct access from the<br />

exterior, a footbath with delayed shut-off tap must be provided for<br />

sand removal.<br />

2.16. Barrier-Free Guestrooms<br />

Provide one handicap accessible guestroom per 100 guestrooms or as designated by<br />

local codes. They shall be situated on the lowest guestroom floors close to the elevator<br />

core. Half of the rooms should be connected to a room with a double/double bed<br />

combination and the other half to a king bed guestroom.<br />

Planning must in accordance with the recommendations of Americans with Disabilities<br />

Act (ADA).<br />

The guest bathrooms are to have the following features:<br />

a) Single entry door shall be 2’10” (0.9 m) wide<br />

b) Additional grab bars in bath recess and adjacent WC. Bars are to<br />

be of the type that are removable when room is not occupied by a<br />

handicapped guest<br />

c) The vanity apron shall be kept as shallow as possible with all<br />

exposed piping insulated.<br />

Top of vanity is to be 2’10” (0.9 m) AFFL<br />

d) All light switches are to be 4’ 0” (1.2 m) on centre line AFFL<br />

REV. MARCH 2006 119<br />

© 2002, Fairmont Hotels and Resorts. All Rights Reserved.