<strong>FAIRMONT</strong> <strong>HOTELS</strong> & <strong>RESORTS</strong> · <strong>DESIGN</strong> <strong>STANDARDS</strong><br />

GUESTROOM AREAS<br />

Windows (continued)<br />

2.11. Mechanical and Electrical<br />

g) Where sliding louvered panels are used in lieu of drapes, a locking<br />

device must be provided on the panels to maintain security when<br />

exterior sliding doors are open.<br />

a) Convectors and grilles with concealed fixings to be painted to<br />

match adjacent surface. Ductwork behind grilles to be painted<br />

matt black<br />

b) Access to the control valves, fan motors and fan scrolls will be<br />

through a 1’6” x 2’6” (0.5 x 0.8 m) return air grille<br />

c) The horizontal fan coil unit is to be designed with a three speed<br />

motor and sized so the unit will provide the required heating or<br />

cooling output when the motor is running at slow speed. The unit<br />

sound level is not to exceed NC30 at slow speed and NC35 at<br />

medium speed. The valves, coils and thermostats must be silent in<br />

operation. The fan coil unit motor must run continuously at the<br />

selected speed and not cycle off when the desired temperature is<br />

achieved<br />

d) Energy smart thermostats to be mounted 54” (137 cm) to centre<br />

line AFFL<br />

e) Incorporate switch in frame of balcony door in humid climates to<br />

close down FCU when door is opened for extended periods of<br />

time<br />

f) Electrical outlets in party walls to be offset by at least 1’0”<br />

(0.3 m) to maintain specified sound ratings<br />

g) Light switches to be mounted 48” (120 cm) to centre line AFFL<br />

h) Electrical outlets to be mounted 1’0” (0.3 m) to centre line AFFL<br />

i) Locate 2 plex outlets at desk as shown on Fairmont Hotels and<br />

Resorts Design Standards Details<br />

j) Install door bell to all suites and guestroom that have extra long<br />

entry foyer<br />

k) Surface mounted ceiling fixtures in entry foyer and bedroom<br />

REV. MARCH 2006 116<br />