<strong>FAIRMONT</strong> <strong>HOTELS</strong> & <strong>RESORTS</strong> · <strong>DESIGN</strong> <strong>STANDARDS</strong><br />

GUESTROOM AREAS<br />

Elevator Lobby (continued)<br />

Provide ceiling coves and chandeliers together with marble trim around elevator<br />

entrances and painted or etched design on elevator doors.<br />

Duplex electrical outlet and telephone outlet at furniture arrangement mounted 22” (56<br />

cm) AFFL.<br />

1.3. Guestroom Support<br />

Provide space for guestroom support facilities and guests convenience, including:<br />

a) Self-service, water-cooled “Manitowoc QPA- 310” (or other equal<br />

and approved) ice dispensing machine in enclosed room. A solid<br />

core door is to be provided at the entrance to the room, together<br />

with full height millwork panels, hinged on the walls, mounted<br />

flush with the front face and installed on either side of the<br />

centrally located ice cube dispensing machine. Vinyl floor<br />

covering below and up to 2’0” (0.6 m) in front of the icedispensing<br />

machine, with the remainder of the area carpeted.<br />

Acoustic ceiling tiles on the entire wall and ceiling surface around<br />

unit to absorb equipment generated noise. The remainder of the<br />

room is to have drywall ceiling. All necessary services are to be<br />

provided to operate the ice dispensing machine together with ½”<br />

(1.3 cm) indirect copper drain lines from ½” (1.3 cm) F.P.T. sump<br />

drain and ½” (1.3 cm) F.P.T. melting tray drain and terminate at<br />

combination funnel floor drain. The room is to have a ceiling<br />

exhaust grille as a louvered door is unacceptable<br />

b) Housekeeping, linen and mini bar storage with the following<br />

features:<br />

Minimum 8' 0" (2.5 m) clear in front of elevators for ease of access<br />

Lockable maids’ room with 18" (46 cm) wide shelving for consumables and 10' (3 m)<br />

of shelving required per 20 bedrooms. As well as a linen storage and control cabinet.<br />

Each half of the cabinet should contain enough linen for all rooms and the volume of<br />

each half should be calculated on the basis of 3 cu. Ft. (0.09 m 3 ) per room. Cabinets to<br />

be lockable and all guestrooms floor cabinets to be keyed alike<br />

REV. MARCH 2006 110<br />