Standard Number<br />

<strong>2012</strong> <strong>Hilton</strong> <strong>Garden</strong> <strong>Inn</strong><br />

<strong>Summary</strong> <strong>of</strong> <strong>Changes</strong><br />

Below is a list <strong>of</strong> items you will not want to miss!<br />

Standard Type Location<br />

Effective August 1, <strong>2012</strong>, all new builds must comply with all Operations (Sections 100-1700) and Design & Construction<br />

standards (Section 2500). Beginning October 1, <strong>2012</strong>, all existing hotels must comply with the following Operation standards<br />

changes. Non-compliance <strong>of</strong> the following items will result in point deductions during quality assurance evaluations unless an<br />

alternative compliance date is indicated. All properties that choose to voluntarily renovate, or do so as required by a PIP must<br />

comply with the Design & Construction standards upon renovation. (updated 8/1/12)<br />

2512.09.C.4.a<br />

2512.09.C.5.a<br />

2512.09.C.6.a<br />

2510.09.C.8.a<br />

2513.07.H<br />

2513.08.B<br />

2513.08.L.1.a<br />

2513.08.Y<br />

2513.08.Y.1<br />

Two soap dishes are required in bathtub/shower combos.<br />

Soap dishes must not have grab handles and must not be<br />

plastic. For shower-only rooms, the single soap dish must<br />

be placed in the corner on the showerhead wall, 48”/1.20<br />

m above the finished floor, and a footrest in the corner<br />

opposite the showerhead on the back wall, 15”/380 mm<br />

above the finished floor. For bathtub/shower combos, the<br />

shower height dish remains in the showerhead corner with<br />

the bathtub height centered on the back wall 24”/610 mm<br />

above the finished floor. Bathtubs or showers with multiple<br />

grab bars required by the local jurisdiction may adjust dish<br />

locations as needed.<br />

One 304 stainless-steel towel shelf with a single bar must<br />

be provided over tubs where shown on the prototype. The<br />

shelf must be 24”/610 mm minimum with 3/4”/19 mm O.D.<br />

shelf and bar tubing. Fourteen-gauge support plates must<br />

be positioned behind the 2"/51 mm minimum-width wall<br />

flange. A 304 stainless-steel, vertical towel rack (ladderstyle)<br />

with three horizontal bars must be provided in<br />

showers where shown on the prototype. The rack must be<br />

18"/450 mm wide minimum with 3/4”/19 mm O.D.<br />

horizontal bar tubing.<br />

18”/450 mm towel bar must be installed immediately<br />

adjacent to vanity. Towel bar is not allowed over the water<br />

closet. The light switches and receptacles at the vanity<br />

must not be concealed when towels are placed on the<br />

towel bar. The towel bar may be mounted on the face <strong>of</strong><br />

the vanity.<br />

Two single or one double robe hook must be provided.<br />

Mount at 6’-0”/1.8 m above the finished floor.<br />

Any electrical equipment must be mounted 6”/150 mm<br />

above floor level to avoid contact with water from potential<br />

leaks.<br />

Provide a minimum area as shown on the prototype plans<br />

for the computer/telecom room. For non-prototypical<br />

hotels with less than 300 guestrooms, a minimum 170<br />

ft²/16 m² room is required. Hotels with more than 300 keys<br />

must increase the size to 270 ft²/25 m².<br />

Floor finish: Electrostatic discharge (ESD) material - tile,<br />

paint, carpet or VCT<br />

Uninterrupted power supply (UPS) is required for the<br />

computer systems.<br />

The system must provide no less than one hour autonomy<br />

for the computer systems attached.<br />

Revision<br />

Revision<br />

Revision<br />

Revision<br />

Addition<br />

Revision<br />

Revision<br />

Addition<br />

Addition<br />

United States, Canada, South<br />

America, Central America,<br />

Mexico, Caribbean<br />

United States, Canada, South<br />

America, Central America,<br />

Mexico, Caribbean<br />

United States, Canada, South<br />

America, Central America,<br />

Mexico, Caribbean<br />

United States, Canada, South<br />

America, Central America,<br />

Mexico, Caribbean<br />

United States, Canada, South<br />

America, Central America,<br />

Mexico, Caribbean<br />

United States, Canada, South<br />

America, Central America,<br />

Mexico, Caribbean<br />

United States, Canada, South<br />

America, Central America,<br />

Mexico, Caribbean<br />

United States, Canada, South<br />

America, Central America,<br />

Mexico, Caribbean<br />

United States, Canada, South<br />

America, Central America,<br />

Mexico, Caribbean<br />

8 <strong>of</strong> 11