EOBD trouble code table<br />

<strong>Trouble</strong><br />

code<br />

PO359<br />

PO360<br />

<strong>Fault</strong> location<br />

Ignition coil I, primarylsecondary - circuit malfunction<br />

Ignition coil J, primarylsecondary - circuit malfunction<br />

lgnition coil K, prirnarylsecondary - circuit malfunction<br />

Ignition coil L, primarylsecondary - circuit malfunction<br />

Misfire detected - fuelling disabled<br />

Camshaft position (CMP) sensor B, bank 1 -<br />

circuit malfunction<br />

Camshaft position (CMP) sensor B, bank 1 -<br />

circuit rangelperformance<br />

Camshaft posit~on (CMP) sensor B, bank 1 -<br />

circuit low input<br />

Camshaft position (CMP) sensor B, bank 1 -<br />

circuit high input<br />

Camshaft position (CMP) sensor B, bank 1 -<br />

circuit intermittent<br />

- --<br />

Timing reference, high resolution signal A - malfunction<br />

Timing reference, high resolution signal A - too many<br />

pulses<br />

Timing reference, high resolution signal A -too few pulses<br />

Timing reference, high resolution signal A - intermittent<br />

erratic pulses<br />

Timing reference, high resolution signal A - no pulses<br />

I Probable cause<br />

Wiring, ignition coil, ECM<br />

Wiring, ignition coil, ECM<br />

1 Wiring, ignition coil, ECM<br />

Wiring, ignition coil, ECM<br />

Fuel system, mechanical fault<br />

Wiring, poor connection, CMP sensor, ECM<br />

Wiring, poor connection, CMP sensor<br />

Wiring short to earth, CMP sensor, ECM<br />

Wiring short to positive, CMP sensor, ECM<br />

Wiring, poor connection, ECM<br />

Wiring, CKPIRPMICMP sensor, ECM<br />

Wiring, CKPIRPMICMP sensor, ECM<br />

Wiring, CKPIRPMICMP sensor, ECM<br />

Wiring, poor connection, CKPIRPMICMP sensor, ECM<br />

Wiring, CKPIRPMICMP sensor, ECM<br />

Timing reference, high resolution signal B - malfunction I Wiring, CKPIRPMICMP sensor, ECM<br />

I<br />

Timing reference, high resolution signal B - too many Wiring, CKPIRPMICMP sensor, ECM<br />

pulses<br />

Timing reference, high resolution signal B -too few pulses Wiring, CKPIRPMICMP sensor, ECM<br />

Timing reference, high resolution signal B - intermittent<br />

erratic pulses<br />

Timing reference, high resolution signal B - no pulses<br />

Glow plugs, circuit A - malfunction<br />

Glow plug warning lamp - circuit malfunction<br />

Glow plugs, circuit B - malfunction<br />

Glow plug control module - circuit low<br />

Glow plug control module - circuit high<br />

Wiring, poor connection, CKPIRPMICMP sensor, ECM<br />

I Wiring, CKPIRPMICMP sensor, ECM<br />

Wiring, glow plug relay, fuse, glow plugs, ECM<br />

Wiring, glow plug warning lamp, ECM<br />

I Wiring, glow plug relay, glow plugs, ECM<br />

Wiring short to earth, glow plug control module<br />

Wiring short to positive, glow plug control module<br />

Crankshaft position (CKP) sensor B - circuit malfunction I Wiring, CKP sensor, ECM<br />

Crankshaft position (CKP) sensor B - rangelperformance Insecure sensorlrotor, air gap, wiring, CKP sensor<br />

problem<br />

Crankshaft position (CKP) sensor B - low input<br />

Wiring short to earth, CKP sensor, ECM<br />

Crankshaft position (CKP) sensor B - high input<br />

Wiring short to positive, CKP sensor, ECM<br />

Crankshaft position (CKP) sensor B - circuit intermittent I Wiring, poor connection, CKP sensor, ECM<br />

I<br />

Camshaft position (CMP) sensor B, bank 2 -<br />

Wiring, poor connection, CMP sensor, ECM<br />

circuit malfunction<br />

Camshaft position (CMP) sensor B, bank 2 -<br />

Wiring, poor connection, CMP sensor<br />

circuit rangelperformance<br />

Camshaft position (CMP) sensor B, bank 2 -<br />

Wiring short to earth, CMP sensor, ECM<br />

circuit low input<br />

Camshaft position (CMP) sensor B, bank 2 -<br />

Wiring short to positive, CMP sensor, ECM<br />

circuit high input<br />

Camshaft position (CMP) sensor B, bank 2 -<br />

circuit intermittent<br />

Wiring, poor connection, ECM<br />