11,6 Astra-F 1,4/1,611,8<br />

System:<br />

14SE, CIZNZ, C14NZ, C14NZ, CIISE, CIGNZ,<br />

C16NZ12, CIGSE, CIGXE, CISNZ, XIZSZ, X14NZ,<br />

X14SZ, XI 4XE, XI GSZ, XI GSZR, XI GXE, XI GXEL<br />

Multec<br />

Except CavalierNectra<br />

General information<br />

0 Refer to the front of this manual for general test conditions,<br />

terminology, detailed descriptions of wiring faults <strong>and</strong> a<br />

general trouble shooter for electrical <strong>and</strong> mechanical faults.<br />

<strong>Trouble</strong> codes are displayed by the malfunction indicator<br />

lamp (MIL).<br />

0 The ECM fault memory can also be checked using<br />

diagnostic equipment connected to the data link connector<br />

(DLC).<br />

Accessing<br />

Ensure ignition switched OFF.<br />

Bridge data link connector (DLC) terminals A <strong>and</strong> B m.<br />

Switch ignition ON.<br />

<strong>Trouble</strong> codes will be displayed after a short flash H [A] <strong>and</strong><br />

a long pause H [El.<br />

Count MIL flashes. Note trouble codes. Compare with<br />

trouble code table.<br />

Each trouble code consists of two groups of one or more<br />

flashes.<br />

The first group of flashes indicate the 'tens' of the trouble<br />

code H [C].<br />

The second group of flashes indicate the 'units' of the<br />

trouble code H [Dl.<br />

A short pause separates each trouble code group H [El.<br />

A long pause separates each trouble code H [Fl.<br />

For example: <strong>Trouble</strong> code 12 displayed H.<br />

Each trouble code including 12 displayed three times.<br />