Model:<br />

Clio 1,5D Turbo Kangoo 1,5D Turbo<br />

Year:<br />

2000-04<br />

Engine code: K9K 700170217041710<br />

System: Lucas common rail<br />

Engine management<br />

Clio<br />

I<br />

General information<br />

Refer to the front of this manual for general test conditions,<br />

terminology, detailed descriptions of wiring faults <strong>and</strong> a<br />

general trouble shooter for electrical <strong>and</strong> mechanical faults.<br />

Accessing <strong>and</strong> erasing<br />

No digital trouble codes available from vehicle<br />

manufacturer.<br />

The engine control module (ECM) fault memory can only be<br />

accessed <strong>and</strong> erased using diagnostic equipment able to<br />

display fault <strong>locations</strong> as a text description.<br />

<strong>Trouble</strong> code identification<br />

<strong>Fault</strong> location<br />

AC control module<br />

AC control module - control circuit<br />

Accelerator pedal position (APP) sensor<br />

Accelerator pedal position (APP)<br />

sensor - track 1<br />

Accelerator pedal position (APP)<br />

sensor - track 2<br />

Barometric pressure (BARO) sensor<br />

Battery voltage - highllow<br />

Brake pedal position (BPP) switch<br />

Camshaft position (CMP) sensor<br />

I Probable cause<br />

Wiring short to earthlopen circuitlshort to positive, AC system, AC control<br />

module<br />

I Wiring short to earthlopen circuitlshort to positive<br />

Wiring short to earthlopen circuitlshort to positive, supply voltage, APP sensor<br />

Wiring short to earthlopen circuitlshort to positive, supply voltage, APP sensor<br />

I Wiring short to earthlopen circuitlshort to positive, supply voltage, APP sensor<br />

ECM<br />

Wiring open circuitlearth wire, battery, alternator<br />

Wiring short to earthlopen circuitlsupply voltage, BPP switch<br />

Wiring open circuit, earth connection, CMP sensor,<br />

valve timing<br />