05.02.2017 Views

Autodata - Diagnostic Trouble Codes Fault locations and probable causes - 2004 edition

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Engine management<br />

Year: 1995-98<br />

Engine code: XUD9BTFIL3 (DHX)<br />

System: Bosch AS3<br />

Xantii - in fascia fusebox<br />

I<br />

I<br />

SynergieEvasion - under fascia, driver's side<br />

General information<br />

Refer to the front of this manual for general test conditions,<br />

terminology, detailed descriptions of wiring faults <strong>and</strong> a<br />

general trouble shooter for electrical <strong>and</strong> mechanical faults.<br />

G <strong>Trouble</strong> codes are displayed by the malfunction indicator<br />

lamp (MIL) or LED.<br />

The ECM fault memory can also be checked <strong>and</strong> erased<br />

using diagnostic equipment connected to the data link<br />

connector (DLC).<br />

0 Vehicles fitted with a coded keypad: When switching on<br />

ignition or entering start code ensure diagnostic equipment is<br />

disconnected from the data link connector (DLC).<br />

Accessing<br />

Switch ignition ON.<br />

Check that MIL illuminates.<br />

Connect LED test lamp between data link connector (DLC)<br />

terminal C3 <strong>and</strong> battery positive m.<br />

Bridge data link connector (DLC) terminal C2 <strong>and</strong> earth with<br />

a switched lead - contacts normally open O.<br />

Operate switch for 2,551 seconds.<br />

LED or MIL will now flash trouble code 12.<br />

Each trouble code consists of two groups of one or more<br />

flashes H.<br />

Long flashes indicate the 'tens' of the trouble code H [A].<br />

Short flashes indicate the 'units' of the trouble code rn [C].<br />

A short pause separates each flash rn [B].<br />

A long pause separates each trouble code<br />

For example: <strong>Trouble</strong> code 12 displayed H.<br />

Repeat operation. Note trouble codes.<br />

Compare with trouble code table.<br />

Rectify faults as necessary.<br />

[Dl.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!