Diagnostic Error Code FRU/Action<br />

025-198-XXX<br />

IDE interface test aborted<br />

025-199-XXX<br />

IDE interface test failed, cause unknown<br />

030-000-XXX<br />

SCSI interface Test Passed<br />

030-00X-XXX<br />

030-01X-XXX<br />

SCSI interface failure<br />

030-027-XXX<br />

SCSI interface Configuration/Setup error<br />

030-03X-XXX<br />

030-04X-XXX<br />

SCSI interface error<br />

030-195-XXX<br />

SCSI interface Test aborted by user<br />

030-196-XXX<br />

SCSI interface test halt, error threshold<br />

exceeded<br />

030-197-XXX<br />

SCSI interface test warning<br />

1. If a component is called out, make sure<br />

it is connected and/or enabled. See<br />

<strong>Chapter</strong> 6, “Using the Setup Utility,” on<br />

page 51<br />

2. Flash the system and re-test. See<br />

“Updating (flashing) BIOS from a<br />

CD-ROM or diskette” on page 786<br />

3. Go to “Undetermined problems” on page<br />

82<br />

1. Go to “Undetermined problems” on page<br />

82<br />

2. Flash the system and re-test. See<br />

“Updating (flashing) BIOS from a<br />

CD-ROM or diskette” on page 786<br />

3. Replace component under function test<br />

No action<br />

1. SCSI signal cable<br />

2. Check power supply<br />

3. SCSI device<br />

4. SCSI adapter card, if installed<br />

5. System board<br />

1. SCSI signal cable<br />

2. Flash the system. See “Updating<br />

(flashing) BIOS from a CD-ROM or<br />

diskette” on page 786<br />

3. SCSI device<br />

4. SCSI adapter card, if installed<br />

5. System board<br />

1. SCSI signal cable<br />

2. Check power supply<br />

3. SCSI device<br />

4. SCSI adapter card, if installed<br />

5. System board<br />

Information only<br />

Re-start the test, if necessary<br />

1. Press F3 to review the log file<br />

2. Re-start the test to reset the log file<br />

1. Make sure the component that is called<br />

out is connected and/or enabled. See<br />

<strong>Chapter</strong> 6, “Using the Setup Utility,” on<br />

page 51<br />

2. Re-run test<br />

3. Replace the component that is called out<br />

in warning statement<br />

4. Replace the component under test<br />

<strong>Chapter</strong> 7. Symptom-to-FRU Index 69