64 Hardware Maintenance Manual Diagnostic Error Code FRU/Action 011-199-XXX Serial port test failed, cause unknown 011-2XX-XXX Serial port signal failure 014-000-XXX Parallel port Interface Test Passed 014-001-XXX Parallel port Presence 014-002-XXX 014-003-XXX Parallel port Timeout/Parity error 014-013-XXX 014-014-XXX Parallel port Control Signal/Loopback test failure 014-015-XXX Parallel port External Loopback failure 014-027-XXX Parallel port Configuration/Setup error 014-03X-XXX 014-04X-XXX Parallel port failure 014-195-XXX Parallel port Test aborted by user 014-196-XXX Parallel port test halt, error threshold exceeded 014-197-XXX Parallel port test warning 1. Go to “Undetermined problems” on page 82 2. Flash the system and re-test. See “Updating (flashing) BIOS from a CD-ROM or diskette” on page 786 3. Replace component under function test 1. External serial device 2. System board No action 1. Remove external parallel device, if present 2. Run setup, enable port 3. System board System board System board 1. Wrap plug 2. System board 1. Run Setup, enable port 2. Flash the system. See “Updating (flashing) BIOS from a CD-ROM or diskette” on page 786 3. System board System board Information only Re-start the test, if necessary 1. Press F3 to review the log file 2. Re-start the test to reset the log file 1. Make sure the component that is called out is connected and/or enabled. See Chapter 6, “Using the Setup Utility,” on page 51 2. Re-run test 3. Replace the component that is called out in warning statement 4. Replace the component under test
Diagnostic Error Code FRU/Action 014-198-XXX Parallel port test aborted 014-199-XXX Parallel port test failed, cause unknown 014-2XX-XXX 014-3XX-XXX Parallel port failure 015-000-XXX USB port Interface Test Passed 015-001-XXX USB port Presence 015-002-XXX USB port Timeout 015-015-XXX USB port External Loopback failure 015-027-XXX USB port Configuration/Setup error 015-032-XXX USB port Device Controller failure 015-034-XXX USB port buffer allocation failure 015-035-XXX USB port Reset condition detected 015-036-XXX USB port Register error 015-040-XXX USB port IRQ failure 015-195-XXX USB port Test aborted by user 1. If a component is called out, make sure it is connected and/or enabled 2. Flash the system and re-test. See “Updating (flashing) BIOS from a CD-ROM or diskette” on page 786 3. Go to “Undetermined problems” on page 82 1. Go to “Undetermined problems” on page 82 2. Flash the system and re-test. See “Updating (flashing) BIOS from a CD-ROM or diskette” on page 786 3. Replace component under function test 1. External parallel device 2. System board No action 1. Remove USB device(s) and re-test 2. System board 1. Remove USB device(s) and re-test 2. System board 1. Remove USB device(s) and re-test 2. System board 1. Flash the system. See “Updating (flashing) BIOS from a CD-ROM or diskette” on page 786 2. System board System board 1. Reboot the system 2. Flash the system and re-test. See “Updating (flashing) BIOS from a CD-ROM or diskette” on page 786 3. Run memory test 4. System board 1. Remove USB device(s) and re-test 2. System board System board 1. Run setup and check for conflicts 2. Flash the system. See “Updating (flashing) BIOS from a CD-ROM or diskette” on page 786 3. System board Information only Re-start the test, if necessary Chapter 7. Symptom-to-FRU Index 65
- Page 19 and 20: ≥18 kg (37 lbs) ≥32 kg (70.5 lb
- Page 21 and 22: CUIDADO: Ao substituir a bateria de
- Page 23 and 24: Chapter 2. Safety information 17
- Page 25 and 26: Chapter 2. Safety information 19
- Page 27 and 28: DANGER Le courant électrique prove
- Page 29 and 30: ≥18 kg (37 lbs) ≥32 kg (70.5 lb
- Page 31 and 32: CAUTION: Eine verbrauchte Lithiumba
- Page 33 and 34: Chapter 2. Safety information 27
- Page 35 and 36: 2 1 Chapter 2. Safety information 2
- Page 37 and 38: ATTENZIONE: Quando si sostituisce l
- Page 39 and 40: Chapter 2. Safety information 33
- Page 41 and 42: PELIGRO La corriente eléctrica pro
- Page 43 and 44: ≥18 kg ≥32 kg ≥55 kg PRECAUCI
- Page 45 and 46: Chapter 3. General information This
- Page 47 and 48: For all machine types Environment A
- Page 49 and 50: Chapter 4. General Checkout Problem
- Page 51 and 52: Chapter 5. Diagnostics PC-Doctor fo
- Page 53 and 54: 7. When prompted, insert a blank, f
- Page 55 and 56: The Full Erase Hard Drive provides
- Page 57 and 58: Chapter 6. Using the Setup Utility
- Page 59 and 60: 3. Select the desired startup devic
- Page 61 and 62: Chapter 7. Symptom-to-FRU Index Har
- Page 63 and 64: Diagnostic Error Code FRU/Action 00
- Page 65 and 66: Diagnostic Error Code FRU/Action 00
- Page 67 and 68: Diagnostic Error Code FRU/Action 00
- Page 69: Diagnostic Error Code FRU/Action 01
- Page 73 and 74: Diagnostic Error Code FRU/Action 01
- Page 75 and 76: Diagnostic Error Code FRU/Action 02
- Page 77 and 78: Diagnostic Error Code FRU/Action 07
- Page 79 and 80: Diagnostic Error Code FRU/Action 08
- Page 81 and 82: Diagnostic Error Code FRU/Action 17
- Page 83 and 84: Diagnostic Error Code FRU/Action 30
- Page 85 and 86: POST error codes Each time you powe
- Page 87 and 88: Miscellaneous error messages Messag
- Page 89 and 90: c. Memory modules d. Extended video
- Page 91 and 92: Chapter 8. Replacing FRUs (Types 70
- Page 93 and 94: Computer components The following i
- Page 95 and 96: Removing the cover Important Read C
- Page 97 and 98: 4. Using the blue handle▌1▐, li
- Page 99 and 100: Replacing the CMOS battery If the C
- Page 101 and 102: 7. Lift the power supply out of the
- Page 103 and 104: 12. Lift the heat sink and fan asse
- Page 105 and 106: Replacing the microprocessor This p
- Page 107 and 108: Notes: a. Note the orientation of t
- Page 109 and 110: Replacing the hard disk drive Impor
- Page 111 and 112: Replacing an optical drive This pro
- Page 113 and 114: Replacing the power switch/LED asse
- Page 115 and 116: Replacing the system fan assembly T
- Page 117 and 118: Completing the FRU replacement Afte
- Page 119 and 120: Chapter 9. Replacing FRUs (Types 70
64 Hardware Maintenance Manual<br />
Diagnostic Error Code FRU/Action<br />
011-199-XXX<br />
Serial port test failed, cause unknown<br />
011-2XX-XXX<br />
Serial port signal failure<br />
014-000-XXX<br />
Parallel port Interface Test Passed<br />
014-001-XXX<br />
Parallel port Presence<br />
014-002-XXX<br />
014-003-XXX<br />
Parallel port Timeout/Parity error<br />
014-013-XXX<br />
014-014-XXX<br />
Parallel port Control Signal/Loopback test<br />
failure<br />
014-015-XXX<br />
Parallel port External Loopback failure<br />
014-027-XXX<br />
Parallel port Configuration/Setup error<br />
014-03X-XXX<br />
014-04X-XXX<br />
Parallel port failure<br />
014-195-XXX<br />
Parallel port Test aborted by user<br />
014-196-XXX<br />
Parallel port test halt, error threshold<br />
exceeded<br />
014-197-XXX<br />
Parallel port test warning<br />
1. Go to “Undetermined problems” on page<br />
82<br />
2. Flash the system and re-test. See<br />
“Updating (flashing) BIOS from a<br />
CD-ROM or diskette” on page 786<br />
3. Replace component under function test<br />
1. External serial device<br />
2. System board<br />
No action<br />
1. Remove external parallel device, if<br />
present<br />
2. Run setup, enable port<br />
3. System board<br />
System board<br />
System board<br />
1. Wrap plug<br />
2. System board<br />
1. Run Setup, enable port<br />
2. Flash the system. See “Updating<br />
(flashing) BIOS from a CD-ROM or<br />
diskette” on page 786<br />
3. System board<br />
System board<br />
Information only<br />
Re-start the test, if necessary<br />
1. Press F3 to review the log file<br />
2. Re-start the test to reset the log file<br />
1. Make sure the component that is called<br />
out is connected and/or enabled. See<br />
<strong>Chapter</strong> 6, “Using the Setup Utility,” on<br />
page 51<br />
2. Re-run test<br />
3. Replace the component that is called out<br />
in warning statement<br />
4. Replace the component under test