A. FISSILE SOLUTION SYSTEMS<br />

1. Los Alamos Scientific Laboratory, December 194937,38 Water boiler reactor; control rods removed by hand; single excursion; insignificant exposure.<br />

This accident occurred when two new control rods<br />

(poisons) were being tested in the water boiler reactor.<br />

The water boiler was a 12 inch diameter stainless steel<br />

spherecontaining 13.6 l <strong>of</strong> uranyl nitrate. In 1949 it<br />

was reflected by thick graphite.<br />

The rods had been installed, and the operator was<br />

manually checking their drop times. After several tests<br />

<strong>of</strong> each individual rod (a safe procedure since one rod<br />

was sufficient to maintain subcriticality) both rods<br />

were pulled, held for about 5 seconds, and then<br />

dropped simultaneously. A short time later the rods<br />

were again pulled and dropped together.<br />

2. Hanford Works, 16 November 1951 39<br />

Plutonium solution assembly; cadmium rod removed too rapidly; single excursion; insignificant exposures.<br />

The critical assembly in which the excursion<br />

occurred was an aqueous solution <strong>of</strong> 1.15 kg <strong>of</strong><br />

plutonium in the form <strong>of</strong> plutonium nitrate contained<br />

in an unreflected 20 inch diameter aluminum sphere.<br />

The purpose <strong>of</strong> the experimental program was to<br />

determine the critical mass <strong>of</strong> plutonium for various<br />

container geometries and solution concentrations. The<br />

excursion occurred during the approach to criticality,<br />

when the sphere was 93% full, as a result <strong>of</strong> withdrawing<br />

a remotely controlled, hollow cadmium safety rod<br />

in a series <strong>of</strong> steps with insufficient time between<br />

steps. The excursion yield was 8 × 10 16 fissions, and a<br />

small amount <strong>of</strong> fuel was forced through gaskets at the<br />

top <strong>of</strong> the reactor assembly. Because the gaskets sealed<br />

about 18 l <strong>of</strong> air above the fuel level before the<br />

accident, pressures considerably in excess <strong>of</strong> atmospheric<br />

must have existed in the assembly during the<br />

accident.<br />

70<br />

The removal <strong>of</strong> the two rods increased the reactivity<br />

to about 3 cents over prompt criticality, corresponding<br />

to a period <strong>of</strong> 0.16 seconds. The power probably rose<br />

with this period to a very broad peak <strong>of</strong> 2 or 3 × 10 16<br />

fissions/s and remained close to this value for about 1.5<br />

seconds. The excursion was not immediately detected<br />

because all the instruments were turned <strong>of</strong>f except for a<br />

direct reading thermometer that showed a temperature<br />

rise <strong>of</strong> 25°C, equivalent to a yield <strong>of</strong> 3 or 4 × 10 16<br />

fissions.<br />

The operator received a 2.5 rad dose. The reactor<br />

was not damaged.<br />

The published data suggest that the reactivity<br />

insertion rate resulting from the safety rod withdrawal<br />

must have been about 4.7 $/s, which would lead to a<br />

fission yield <strong>of</strong> about twice the observed value if<br />

known temperatures and void coefficients <strong>of</strong> reactivity<br />

are used. In this case, however, the action <strong>of</strong> the scram<br />

circuit was sufficiently fast that the cadmium rod most<br />

probably contributed to the shutdown <strong>of</strong> the excursion.<br />

A slight reduction in the assumed reactivity insertion<br />

rate would lengthen the time, making it even more<br />

certain that the excursion was stopped by the falling<br />

poison rod.<br />

No personnel were injured in this excursion,<br />

although plutonium nitrate solution contaminated the<br />

experimental area. The building was successfully<br />

decontaminated in a few days, but before cleanup <strong>of</strong><br />

the test area was completed, a fire occurred and the<br />

building was abandoned.