10.11.2016 Views

Spaenaur

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

G<br />

Connector Housings .093"/.062"<br />

Logements des raccords<br />

.093" (2,36 mm) Plug and Receptacle Housings<br />

.093" STANDARD* 3191<br />

SERIES<br />

SERIES<br />

.198" Grid Spacing .264" Grid Spacing<br />

APPROVALS:<br />

U.L. Yes Yes<br />

C.S.A. Yes Yes<br />

V.D.E. N/A Yes<br />

Japanese (EAMCL) N/A Yes<br />

250 V.A.C. Yes Yes<br />

600 V.A.C. 1812 - 2, 3 and 4 only Yes<br />

Current Rating 1-3 circuits - 12 amps 1-2 circuits - 12 amps 9 circuits - 8 amps<br />

4-9 circuits - 9 amps 3 circuits - 11 amps 12 circuits - 7 amps<br />

12-15 circuits - 7.5 amps 4 & 6 circuits - 9 amps 15 circuits - 6 amps<br />

FEATURES:<br />

**Not all circuit sizes<br />

Both housings fully insulate terminals No Yes<br />

Pin and socket terminals used in either housing Yes Yes<br />

Accepts .093" crimp terminals Yes Yes<br />

Accepts .093" P.C. tail terminals Yes Yes<br />

U.L. 94V-2 rating Yes Yes<br />

Positive locking 1816 & 2629 only** Yes<br />

Passive locking Yes, except 1816 & No<br />

2629 only**<br />

Circuit sizes available 1-6, 9, 12, and 15 1-4, 6, 9, 12, and 15<br />

Fully polarized Yes Yes<br />

Dual locking tangs Yes Yes<br />

OPTIONS:<br />

Mounting ears Yes Yes (Receptacle<br />

available only with ears)<br />

Dyed for color code Yes Yes<br />

94V-0 No Yes<br />

Pull tabs for gripping 15 circuits and less No<br />

receptacles only<br />

.062" (1,58 mm) Plug and Receptacle Housing 5025 SERIES 1625/1649/1772/2004 SERIES<br />

.180" Grid Spacing .145" Grid Spacing*<br />

APPROVALS:<br />

U.L. Yes Yes<br />

C.S.A. Yes Yes<br />

V.D.E. Yes No<br />

Japanese (EAMCL) Yes No<br />

250 V.A.C. Rating Yes Yes<br />

5 amp Rating Yes Yes<br />

4 amps on 24 and 36 circuit<br />

FEATURES:<br />

Circuit Sizes 2, 3, 4, 6, 9, 12, and 15 1-6, 8, 9, 12, 15, 24, and 36<br />

Both housings fully insulate terminals Yes No - Receptacle only<br />

Pin and socket terminals used in either housing Yes No<br />

Accepts .062" crimp terminals Yes Yes<br />

Accepts .062" P.C. tail terminals No Yes - No current rating<br />

U/L 94 V2 housing Yes Yes<br />

Positive locking Yes No<br />

Passive locking No Yes<br />

Fully polarized Yes Yes<br />

Dual locking tangs Yes Yes<br />

Accepted wire gauges #14-28 AWG #18-30 AWG<br />

OPTIONS:<br />

Mounting Ears Yes Yes<br />

Dyed for color code Yes Yes<br />

Accepts 5005/5006/5206 terminals Yes N/A<br />

*36 circuit has .165" grid spacing<br />

G66<br />

Inch<br />

Pouces<br />

CATALOG 13

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!