CATALOG 13<br />

Pocket Pull ® Flush Handle<br />

• Flush installation<br />

• For lifting or pulling<br />

• Lifting load transferred directly to panel edge<br />

• Single-hole, screw-mount installation<br />

22.4<br />

(.88)<br />

25.5<br />

(1.00) 121.5 (4.78)<br />

64.3<br />

(2.53)<br />

CUP<br />

2.5 (.09)<br />

PANEL THICKNESS<br />

LIFT<br />

46.7<br />

(1.84)<br />

Installation<br />

1. Prepare a rectangular<br />

opening as shown.<br />

38 +0.2<br />

-0.0<br />

(1.500±.005)<br />

114.30±0.25<br />

(4.500±.010)<br />

0.7 (.03) R MAX.<br />

Product Strength<br />

Guidelines<br />

(Distributed Load)<br />

23<br />

(.90)<br />

Lifting, Pulling<br />

91.5 (3.60)<br />

123 (4.84)<br />

Maximum working load 1300 N (300 lbs.)<br />

Average ultimate load 2700 N (600 lbs.)<br />

Snap-in design<br />

• Fast, efficient installation<br />

• One-piece design<br />

• Compact envelope<br />

• For lifting or pulling<br />

• Two sizes<br />

• Low Gloss Black ABS<br />

Product Strength Guidelines<br />

(forces applied as shown)<br />

*Based on installation in 1.2 mm<br />

(.048 in.) steel panel.<br />

Maximum loads limited by panel<br />

strength.<br />

Maximum. working load* = 1800 N (400 lbs.)<br />

Average. ultimate load* = 5300 N (1200 lbs.)<br />

2. Place pull in panel,<br />

seating the slot<br />

against top of<br />

opening.<br />

Matte Finish<br />

on these<br />

surfaces<br />

INSTALLATION<br />

1. Prepare a<br />

rectangular<br />

opening as<br />

shown.<br />

87.5±0.3 (3.45±.01)<br />

30.7±0.15<br />

(1.210±.005)<br />

2. Engage edge of opening under flange<br />

of pull.<br />

3. Firmly snap in opposite flange with a<br />

rocking motion.<br />

SPAENAUR No's.<br />

ABS, Black ABS, Black<br />

UL94-HB UL94-VO<br />

PANEL THICKNESS<br />

1 (.040) MIN.<br />

1.8 (.070) MAX.<br />

097-439 —<br />

Mfr. #P1-30-101-11<br />

Pushing, Sliding<br />

Maximum working load<br />

450 N (100) lbs.<br />

Average ultimate load<br />

670 N (150) lbs.<br />

127.3 (5.01) larger P2<br />

132±0.3 (5.20±.01)<br />

R MAX.<br />

1.5 (.06)<br />

Pulls and Door Retaining Springs<br />

Poignées et Ressorts de retenue pour porte<br />

Other Panel Thickness Range to 3.3 (.130)<br />

available Special Order.<br />

Material and Finish<br />

PULL and CUP: ABS, black.<br />

SCREWS: Steel, zinc plated plus bright<br />

chromate dip.<br />

82.5 (3.25) smaller P2<br />

TYP. 5.3 (.21)<br />

R 1 (.040) TYP.<br />

NOTE:<br />

Installation in a panel thickness less than the maximum<br />

for each range allows some movement of the pull.<br />

3. Attach cup to pull<br />

and back of panel<br />

with two screws<br />

(supplied).<br />

;;; yyy<br />

Operating Temperature Range:<br />

-50°C to 60°C (-60°F to 140°F)<br />

Maximum recommended tightening torque for<br />

mounting screws is 0.5 N•m (5 in.-lbs.)<br />

R 1.5<br />

(.06)<br />

25.5<br />

(1.00)<br />

millimeter (inch)<br />

Dimensions without tolerances<br />

are for reference only.<br />

Panel Thickness<br />

Tel: 1-800-265-8772 Fax: 519-744-0818<br />

;;; yyy<br />

;;; yyy<br />

35.8<br />

(1.41)<br />

17<br />

(0.65)<br />

40<br />

(1.58)<br />

REF.<br />

1.8 (.07)<br />

SPAENAUR No. PANEL THICKNESS<br />

Large Small Min. Max.<br />

097-444 097-440 1 (.040) 1.4 (.055)<br />

Mfr. #P2-51 Mfr. #P2-41<br />

097-445 097-441 1.4 (.055) 1.8 (.070)<br />

Mfr. #P2-52 Mfr. #P2-42<br />

097-446 097-442 1.8 (.070) 2.1 (.085)<br />

Mfr. #P2-53 Mfr. #P2-43<br />

097-447 097-443 2.1 (.085) 2.5 (.100)<br />

Mfr. #P2-54 Mfr. #P2-44<br />

Maximum working load* = 450 N (100 lbs.)<br />

Average ultimate load* = 650 N (150 lbs.)<br />

L141<br />

L