Murox building system<br />
FIRE-RESISTANCE RATED WALL<br />
The Murox wall panel can also be designed to provide a UL/ULC-certified one-hour<br />
fire resistance rating from interior to exterior. The panel is available for loadbearing<br />
and non-bearing walls. Two-hour fire resistance rating (not certified) wall<br />
construction UL\ULC is available.<br />
Test method Fire resistance Assembly number<br />
CAN/ULC S101 - Standard Methods of Fire<br />
Endurance Tests of Building Construction and<br />
Materials<br />
1 hour W011<br />
Murox certified 1-hour fire rating<br />
ULC Design - W011<br />
UL Design - U048<br />
VENTILATED THERMAL PANEL<br />
The ventilated thermal panel (VTP) makes it possible to capture solar energy to<br />
preheat the fresh air used by air makeup units. Up to 25% of the cost to heat fresh<br />
air for the building can thus be saved. What's more, the system is simple: negative<br />
pressure in the wall's plenum causes air to be drawn through perforations at the<br />
base of this chamber.<br />
Practically the same thickness as a regular Murox wall, it matches the rest of the<br />
building perfectly. Complete shop-assembly of the VTP provides for very quick<br />
installation on site.<br />
Class Class description Performance factor<br />
8854-01<br />
VERIFICATION OF SOLAR COLLECTOR<br />
Solar Collector Checklist CAN/CSA-F378<br />
0.58<br />
Murox I Firewall type of wall<br />
Murox I Ventilated thermal panel<br />
11