Suretta Sud Glacier - Servizio Glaciologico Lombardo
Suretta Sud Glacier - Servizio Glaciologico Lombardo
Suretta Sud Glacier - Servizio Glaciologico Lombardo
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
<strong>Suretta</strong> <strong>Sud</strong> <strong>Glacier</strong> (Spluga-Lei Sector) 1<br />
Mass balance evaluation by geodetic method<br />
Since 2002, the net mass balance of the <strong>Suretta</strong><br />
<strong>Sud</strong> <strong>Glacier</strong> is calculated by comparing the<br />
surface DEMs (Digital Elevation Models) acquired<br />
by direct field surveys using the differential<br />
GPS technique (Tamburini et al., 2003).<br />
1 For the methodology see www.sgl.cluster.it<br />
- 51 -<br />
The initial reading was taken in September,<br />
2001; the successive measurements were<br />
repeated at the end of each ablation season.<br />
Figs. 1 e 2: The <strong>Suretta</strong> <strong>Sud</strong> <strong>Glacier</strong>, 2 photos taken respectively on September 5, 2004 and on August<br />
28, 2001. The effect of the torrid 2002 and 2003 summers on the glacial mass is clearly visible.<br />
Survey equipment and methodology<br />
The surveys of the glacier have been conducted<br />
by using 2 GPS receivers operating in<br />
a differential mode; the first one (rover) is carried<br />
on the operator’s shoulders, the second<br />
one (reference), is installed on the reference<br />
point established during the 1st measurement,<br />
in order to have the possibility to overlap<br />
the surveys executed in different years,<br />
hence, making possible a direct comparison.<br />
2 GPS TRIMBLE 4000SSE receivers with<br />
a geodetic antenna and dual frequency (or<br />
equivalents) were used for the purpose; these<br />
tools are able to record the phase on which the<br />
GPS signal is modulated, allowing the determination<br />
of the coordinates of the route covered<br />
with centimetric accuracy (typically + 1 cm hor-<br />
izontally and + 2 cm vertically). With this equipment<br />
it is possible to operate in RTK (real time<br />
kinematic) mode whenever there is a direct<br />
radio or GSM link between the two stations,<br />
or else, if a continuous link between the stations<br />
is not possible, in post processing mode.<br />
Considering the characteristics of the area and<br />
the logistic conditions, the latter method was<br />
selected. The need to move along paths able to<br />
produce a detailed model of the surface while,<br />
at the same time, retracing the tracks of the previous<br />
surveys, have prompted the operators to<br />
visualize their movements over the glacial surface<br />
with a Mobile GIS Station constituted by:<br />
• Handheld Compaq PC,<br />
equipped with a Bluetooth door;<br />
mass balance