GEIS BuyLog Catalog

02.08.2016 Views

GE Industrial Solutions BuyLog Low and Medium Voltage Components and Equipment

GE<br />

Industrial Solutions<br />

<strong>BuyLog</strong> <br />

Low and Medium Voltage Components and Equipment


<strong>BuyLog</strong> <br />

Quick Index and Table of Contents<br />

Quick Index<br />

Table of Contents<br />

Introduction<br />

1 Load Centers and Circuit Breakers<br />

2 Modular Metering<br />

3 Electric Vehicle Charging Stations<br />

4 Safety Switches<br />

5 Surge Protection Devices (SPD)<br />

6 Molded Case Circuit Breakers<br />

7 Circuit Breaker Enclosures<br />

Low Voltage Power &<br />

8 Insulated Case Circuit Breakers<br />

Disconnect Switches and<br />

9 Operating Mechanisms<br />

10 Dry Type Transformers<br />

11 Panelboards<br />

12 Switchboards<br />

13 Busway<br />

14 Automatic Transfer Switches<br />

15 Motor Control Centers—Low Voltage<br />

16 Switchgear — Low Voltage<br />

17 Entellisys 5.0 Low-Voltage Switchgear<br />

18 Medium Voltage Equipment<br />

19<br />

Paralleling Switchgear<br />

Critical Power Products<br />

20 Uninterruptible Power Supplies<br />

21 Telecommunication Hardware<br />

22<br />

23<br />

24<br />

25<br />

Capacitors, Arresters and<br />

Harmonic Filters<br />

Distribution Transformers–Medium<br />

and High Voltage<br />

26 DC Power Systems<br />

27<br />

28<br />

29<br />

Relays and Meters<br />

Meters and Instrument Transformers<br />

RV Power Pedestals<br />

GE Publication Index<br />

Time Current Curves and<br />

Outline Drawings<br />

30 GE Product Index<br />

Section 1: Load Centers and Circuit Breakers<br />

Q-Line Circuit Breakers– Product Features and Benefits........1-2<br />

PowerMark Gold Load Centers—<br />

Product Features and Benefits ........................................................1-3<br />

PowerMark Gold and Plus Load Centers—<br />

Product Number Guides......................................................................1-4<br />

Q-Line Plug-in Circuit Breakers............................................................1-5<br />

Special Purpose Circuit Breakers........................................................1-6<br />

PowerMark Gold and Plus Single-Phase Load Centers—<br />

Main Lug Convertible to Main Breaker.........................................1-9<br />

Main Breaker Factory Installed .....................................................1-12<br />

PowerMark Plus Three-Phase Load Centers—<br />

Main Circuit Breakers or Main Lugs Factory Installed .......1-14<br />

PowerMark Gold Load Centers—Specialty Panels...................1-17<br />

PowerMark Gold Meter Socket Load Centers ............................1-18<br />

Field Installed Accessories...................................................................1-24<br />

Wiring Diagrams ......................................................................................1-30<br />

Load Centers and Meter Socket Load Centers—<br />

Knockouts................................................................................................1-37<br />

Section 2: Modular Metering<br />

Mini Mod III Nomenclature.....................................................................2-2<br />

Mini Mod III—Ring Type and Ringless................................................2-3<br />

Mini Mod III—Tenant Main Circuit Breakers ...................................2-4<br />

Mini Mod III—Factory Installed Accessories...................................2-5<br />

Mini Mod III—Field Installed Accessories.........................................2-6<br />

Meter Mod III Nomenclature.................................................................2-7<br />

Meter Mod III—How to Order; Short Circuit Ratings ..................2-8<br />

Meter Mod III—Modular Metering Series Ratings........................2-9<br />

Meter Mod III—Main Breaker Modules,<br />

Single-Phase and Three-Phase.....................................................2-11<br />

Factory Installed Accessories ........................................................2-13<br />

Meter Mod III—Main Fusible Modules,<br />

Single-Phase and Three-Phase.....................................................2-14<br />

Factory Installed Accessories ........................................................2-15<br />

Meter Mod III—Main Fusible with Pull<br />

Box and Main Lug Modules<br />

Single-Phase and Three-Phase.....................................................2-16<br />

Factory Installed Accessories ........................................................2-17<br />

Meter Mod III—Main Pull Box<br />

Modules and Accessories<br />

Single-Phase and Three-Phase.....................................................2-18<br />

Meter Mod III—Meter Stack Modules,<br />

Single-Phase Plus Accessories ......................................................2-19<br />

Meter Mod III—Meter Stack Modules,<br />

Three-Phase Plus Accessories.......................................................2-23<br />

Meter Mod III—Meter Stack Modules,<br />

Phase Balancing...................................................................................2-24<br />

Meter Mod III—Applications Where<br />

Center-Feeding Main Module is Required................................2-25<br />

Mini Mod III—Enclosure Knockout Dimensions..........................2-26<br />

Meter Mod III—Enclosure Knockout Dimensions......................2-27<br />

© 2013 General Electric Company, All Rights Reserved.<br />

TM indicates a trademark of the General Electric Company and/or its subsidiaries.<br />

Rev. 11/13<br />

Data subject to change<br />

without notice<br />

www.geindustrial.com <strong>BuyLog</strong> <strong>Catalog</strong><br />

1


<strong>BuyLog</strong> <br />

Table of Contents<br />

Section 3: Electric Vehicle Charging Stations<br />

Introduction .....................................................................................................3-2<br />

Selection Guide ..............................................................................................3-3<br />

Commercial WattStation <br />

Overview, Features and Benefits ........................................................3-4<br />

WattStation Pedestal EV Charger<br />

Specifications and Ordering Information ....................................3-5<br />

WattStation Wall Mount EV Charger<br />

Specifications and Ordering Information ....................................3-6<br />

Commercial DuraStation <br />

Overview, Features and Benefits ........................................................3-7<br />

Specifications and Ordering Information........................................3-8<br />

Connect Software<br />

Overview, Features and Benefits ........................................................3-9<br />

Specifications and Ordering Information.....................................3-10<br />

Residential Charging Stations Wall Mount Units<br />

Overview, Features and Benefits......................................................3-11<br />

Specifications and Ordering Information.....................................3-12<br />

Section 4: Safety Switches<br />

Quick Selection Guide, Enclosure Types...................................4-2<br />

General Duty, Type TG .................................................................4-5<br />

Heavy Duty, Type TH....................................................................4-7<br />

Heavy Duty Stainless Steel, Type TH ......................................4-11<br />

Mill Duty, Type TH.......................................................................4-13<br />

Double Throw Switches, Type TC, TDT....................................4-15<br />

Emergency Power Transfer Switches, Type TC.....................4-18<br />

AC Disconnects ..........................................................................4-19<br />

Accessories: NEMA Type 1 and 3R Enclosures......................4-20<br />

Accessories: NEMA Type 4/4X, 12 and<br />

Mill Duty Enclosures.............................................................4-22<br />

Additional Accessories ..............................................................4-24<br />

Enclosure and Knockout Dimensions ............4-26 through 4-36<br />

Section 5: Surge Protection Devices (SPD)<br />

Critical Power Products<br />

Introduction ..................................................................................................5-2<br />

Integrated Tranquell ME (to connect with<br />

GE “A” Series Panelboards) .................................................................5-3<br />

Integrated Tranquell HE and ME<br />

(for GE Distribution Equipment)........................................................5-5<br />

Tranquell 9X and 24X (Box Extensions for<br />

GE “A” Series Distribution Equipment) ...........................................5-8<br />

Tranquell HE and ME (Wall Mount)................................................5-12<br />

Tranquell ME and LE (Wall Mount).................................................5-18<br />

Tranquell DIN Rail Mount...................................................................5-20<br />

Protection Block Assembly..................................................................5-22<br />

Section 6: Molded Case Circuit Breakers<br />

Industrial Circuit Breakers<br />

How to Order................................................................................................6-2<br />

Features..........................................................................................................6-4<br />

Quick Reference Guide ............................................................................6-6<br />

Q-Line Circuit Breakers<br />

Plug-In 120/240V Class.........................................................................6-14<br />

Plug-In 240V Class ..................................................................................6-16<br />

Bolt-On 240V Class .................................................................................6-20<br />

Cable-In Cable Out (lug-lug) 240V Class.......................................6-25<br />

Introduction<br />

DIN-Rail Mount 240V Class .................................................................6-27<br />

Cable-In Cable Out (lug-lug) 240V Class.......................................6-28<br />

Molded Case Switches 240V Class..................................................6-29<br />

Accessories 240V Class ........................................................................6-30<br />

Thermal Magnetic Trip<br />

15-100A Type TEY/TEYF Bolt-On ......................................................6-32<br />

15-125A Type TEYD/TEYH/TEYL........................................................6-33<br />

10-150A E-150 Line Types TEB, TED, THED ................................6-35<br />

125-600A J600 Line Types TJJ, TJK, THJK....................................6-37<br />

Internal Accessories – Molded Case Circuit Breakers<br />

Accessory Devices and Ratings........................................................6-39<br />

Auxiliary Switches....................................................................................6-40<br />

Shunt Trip ....................................................................................................6-41<br />

Undervoltage Release ...........................................................................6-43<br />

Spectra RMS<br />

15-150A, SE150 Frame .........................................................................6-45<br />

70-250A, SF250 Frame .........................................................................6-47<br />

125-600A, SG600 Frame......................................................................6-49<br />

300-1200A, SK1200 Frame.................................................................6-52<br />

Spectra RMS with microEntelliGuard Trip Unit<br />

Features .......................................................................................................6-54<br />

microEntelliGuard Trip Unit Characteristics..............................6-55<br />

How to Order .............................................................................................6-56<br />

60-600A, SG600 Line..............................................................................6-58<br />

300-1200A, SK1200 Line......................................................................6-60<br />

Accessories for Spectra RMS Circuit Breakers with<br />

microEntellGuard Trip Units<br />

Power Management System Accessories....................................6-62<br />

Other Accessories....................................................................................6-66<br />

Internal Accessories ...............................................................................6-67<br />

Record Plus <br />

15-100A, FB Line......................................................................................6-69<br />

FB Internal Accessories.........................................................................6-73<br />

FB External Accessories........................................................................6-74<br />

15-100A, FC Line......................................................................................6-75<br />

FC Internal Accessories.........................................................................6-78<br />

FC External Accessories........................................................................6-79<br />

25-250A, FE Line ......................................................................................6-80<br />

FE Internal Accessories.........................................................................6-82<br />

FE External Accessories........................................................................6-82<br />

100-600A, FG Line...................................................................................6-84<br />

FG with PremEon S................................................................................6-85<br />

FG with SMR2 ...........................................................................................6-86<br />

FG Internal Accessories ........................................................................6-88<br />

FG External Accessories .......................................................................6-89<br />

Molded Case Switches – 100-1200 A ......................................6-90<br />

Motor Circuit Protectors<br />

3-250A Spectra RMS Mag Break ....................................................6-91<br />

125-1200A Spectra RMS Mag Break ............................................6-92<br />

25-600A Record Plus Mag Break......................................................6-93<br />

External Accessories<br />

Cable Operators .......................................................................................6-94<br />

Flange-Mounted Operators ................................................................6-96<br />

Door Mounted Operators.....................................................................6-98<br />

Motor Operators and Plug-in Hardware....................................6-100<br />

Mechanical Interlocks and Locking Devices............................6-101<br />

Breaker Mounting Hardware and Kits ........................................6-102<br />

Lugs and Associated Hardware.....................................................6-103<br />

Neutral Grounds and Sensors.........................................................6-105<br />

2<br />

<strong>BuyLog</strong> <strong>Catalog</strong><br />

www.geindustrial.com Rev. 11/13<br />

Data subject to change<br />

without notice


<strong>BuyLog</strong> <br />

Table of Contents<br />

Plug-in Hardware..................................................................................6-106<br />

Section 7: Circuit Breaker Enclosures<br />

NEMA Type 1 Enclosures .............................................................7-2<br />

NEMA Type 3R Enclosures...........................................................7-3<br />

NEMA Type 12 Enclosures ...........................................................7-4<br />

NEMA Type 4/4X Enclosures .......................................................7-5<br />

Hubs and Other Accessories ......................................................7-6<br />

Dimensions and Outline Drawings............................................7-7<br />

Dimensions and Knockout Drawings........................................7-8<br />

Section 8: Low Voltage Power & Insulated Case Circuit Breakers<br />

Low Voltage Power and DC Circuit Breakers<br />

EntelliGuard G Low Voltage Power Circuit Breakers............8-2<br />

Overview and Functions ........................................................................8-2<br />

EntelliGuard TU Trip Units.....................................................................8-4<br />

Product Nomenclature ............................................................................8-5<br />

Cassettes Nomenclature......................................................................8-11<br />

Accessories.................................................................................................8-13<br />

WavePro Circuit Breakers with EntelliGuard TU,<br />

Power+, Enhanced MicroVersaTrip Plus and<br />

MicroVersaTrip PM Trip Unit Systems.............................8-24<br />

WavePro Low Voltage Power Circuit Breakers .....................8-26<br />

OEM Substructures and Substructure Accessories .............8-40<br />

Trip Units......................................................................................8-49<br />

Overview – EntelliGuard TU, Power+ and<br />

Enhanced MicroVersaTrip .............................................................8-49<br />

Product Number Nomenclature System ......................................8-55<br />

Trip Unit Conversion Kits Introduction...................................8-66<br />

Overview – EntelliGuard TU, and<br />

MicroVersaTrip PM Conversion Kits ...........................................8-67<br />

Remanufactured MVT Trip Unit<br />

Overview and Features......................................................................8-69<br />

ProTrip Trip Unit Conversion Kits Selection Guide .................8-70<br />

ProTrip Rating Plugs .............................................................................8-74<br />

EntelliGuard TU Trip Unit Conversion<br />

Kits Selection Guide.............................................................................8-76<br />

EntelliGuard TU Trip Rating Plugs ..................................................8-80<br />

EntelliGuard TU Trip Unit Conversion Kit<br />

Accessories and Hardware..............................................................8-81<br />

Trip Unit Accessories..............................................................................8-83<br />

Asbestos Free Arc Quencher Replacement Kits ...................8-85<br />

Gerapid High Speed DC Circuit Breakers...............................8-86<br />

Features and Benefits ...........................................................................8-86<br />

Technical Data ..........................................................................................8-88<br />

Outline Drawings and Dimensions..................................................8-89<br />

Insulated Case Circuit Breakers<br />

Power Break II............................................................................8-91<br />

Features .......................................................................................................8-91<br />

Construction Options.............................................................................8-92<br />

EntelliGuard TU Trip Unit Features ................................................8-93<br />

Power+ Trip Unit Features...................................................................8-94<br />

Enhanced MicroVersaTrip Trip Unit Features...........................8-95<br />

Trip Unit Characteristics.......................................................................8-96<br />

Power Break II Nomenclature System.........................................8-99<br />

Product Number Nomenclature System ...................................8-104<br />

Interrupting Capacity and Withstand Ratings........................8-108<br />

How to Order...........................................................................................8-109<br />

Introduction<br />

Frame Selection (Old Structure) .....................................................8-110<br />

Trip Unit Selection.................................................................................8-111<br />

Enhanced MicroVersaTrip Rating Plug Selection.................8-113<br />

Stationary and Draw-out Switch Selection ..............................8-114<br />

Stationary and Draw-out Breaker Accessories ......................8-115<br />

Stationary Breaker Mounting Kits .................................................8-121<br />

Stationary Breaker Mounting Kits,<br />

Wall Mounted Enclosures, Floor Mounted Enclosures .....8-122<br />

Neutral Current Sensors and<br />

POWER LEADER Accessories ......................................................8-123<br />

Draw-out Breaker Accessories.......................................................8-124<br />

Reference Publications............................................................8-126<br />

Section 9: Disconnect Switches and Operating Mechanisms<br />

HPC High-Pressure Contact Switch<br />

Overview.........................................................................................................9-2<br />

HPC Switch, New Generation, Nomenclature System............9-6<br />

Frame Product Number Nomenclature...........................................9-8<br />

EntelliGuard Control Unit Nomenclature....................................9-10<br />

Application Information, Outlines and Dimensions.................9-11<br />

How to Order .............................................................................................9-13<br />

Accessories.................................................................................................9-14<br />

Reference Publications .........................................................................9-22<br />

Premium Duty QMW, Heavy Duty QMR<br />

Individual Components.........................................................................9-23<br />

Factory Assembled Fuse Clips...........................................................9-25<br />

Handle Operators<br />

Product Ordering Tables.......................................................................9-28<br />

Accessories and Modifications..........................................................9-29<br />

General-Duty HCI<br />

Individual Components.........................................................................9-31<br />

TDR Handle Mechanism<br />

Handle Operating Mechanisms ........................................................9-33<br />

FD1 Fusible IEC Style<br />

Individual Components.........................................................................9-34<br />

Accessories.................................................................................................9-35<br />

Outlines and Dimensions.....................................................................9-37<br />

DILOS Nonfusible Vu-Break IEC Style<br />

Individual Components.........................................................................9-38<br />

Accessories.................................................................................................9-39<br />

Outlines and Dimensions.....................................................................9-40<br />

Section 10: Dry Type Transformers<br />

General Information<br />

Types QB, QMS, QL and TransforMore .........................................10-2<br />

General Purpose<br />

Single-Phase TP-1, Aluminum............................................................10-4<br />

Single-Phase TP-1, Copper..................................................................10-5<br />

Three-Phase TP-1, Aluminum ............................................................10-6<br />

Three-Phase TP-1, Copper...................................................................10-9<br />

K-Factor<br />

Three-Phase TP-1, Aluminum..........................................................10-10<br />

Three-Phase TP-1, Copper................................................................10-14<br />

K-Factor Low Noise<br />

Three-Phase TP-1, Aluminum..........................................................10-18<br />

Three-Phase TP-1, Copper................................................................10-20<br />

Low Noise<br />

Three-Phase TP-1, Aluminum..........................................................10-22<br />

Three-Phase TP-1, Copper................................................................10-23<br />

Rev. 11/13<br />

Data subject to change<br />

without notice<br />

www.geindustrial.com <strong>BuyLog</strong> <strong>Catalog</strong><br />

3


<strong>BuyLog</strong> <br />

Table of Contents<br />

Noise Isolation – Guard I<br />

Three-Phase TP-1, Aluminum..........................................................10-24<br />

Three-Phase TP-1, Copper................................................................10-25<br />

Noise Isolation – Guard II .......................................................10-26<br />

Three-Phase TP-1, Aluminum..........................................................10-27<br />

Three-Phase TP-1, Copper................................................................10-28<br />

Harmonic Mitigating – Guard III<br />

Three-Phase TP-1, Copper................................................................10-29<br />

Ultra Energy Efficient<br />

Three-Phase CSL-3, NEMA Premium , Copper........................10-30<br />

K-Factor, Three-Phase NEMA Premium , Copper ..................10-31<br />

Harmonic Mitigating,<br />

Three-Phase NEMA Premium , Copper ...................................10-32<br />

Servicenter Mini-Unit Substations –<br />

Integral Transformer and Distribution Center...................10-33<br />

Single-Phase and Three-Phase ......................................................10-34<br />

Outlines, Dimensions, Wiring Diagrams.....................................10-35<br />

Totally Enclosed, Nonventilated – TENV ..............................10-36<br />

Aluminum and Copper .......................................................................10-37<br />

Midtapped<br />

Aluminum..................................................................................................10-38<br />

Copper........................................................................................................10-39<br />

Drive Isolation<br />

Three-Phase.............................................................................................10-40<br />

Accessories and Lugs ..............................................................10-42<br />

Enclosure Parts.........................................................................10-44<br />

Wiring Diagrams ......................................................................10-45<br />

Dimensions................................................................................10-46<br />

General Purpose Transformers in Enclosures<br />

Single-Phase............................................................................................10-47<br />

Buck-Boost Encapsulated Transformers .............................10-50<br />

Selection Tables.....................................................................................10-53<br />

Connection Diagrams.........................................................................10-60<br />

Open Core and Coil Transformers ........................................10-61<br />

Machine Tool Applications................................................................10-62<br />

Control........................................................................................................10-63<br />

Options and Fusing Guide ................................................................10-65<br />

Wiring Diagrams ...................................................................................10-66<br />

Outlines and Dimensions ..................................................................10-67<br />

CE-Rated....................................................................................................10-68<br />

Section 11: Panelboards<br />

A-Series II Panelboards<br />

Applications................................................................................................11-3<br />

Types..............................................................................................................11-4<br />

Terminal Lugs ............................................................................................11-7<br />

Pricing and Ordering ..............................................................................11-8<br />

Column Panels ..........................................................................................11-9<br />

Column – Field Installed Kits/Replacement<br />

Parts/Enclosures.................................................................................11-10<br />

Lighting Control Panel—Remote Operated<br />

Circuit Breakers...................................................................................11-11<br />

Pro-Stock Panelboards – Unassembled.....................................11-13<br />

Product Options.....................................................................................11-19<br />

Accessories ..............................................................................................11-20<br />

Power Panelboards ..............................................................................11-21<br />

Branch Circuit Monitoring.................................................................11-23<br />

AMP1 Integrated Power and Energy............................................11-24<br />

Introduction<br />

Spectra Series Panelboards..................................................11-25<br />

Fusible Switches Load and Interrupting Ratings ...................11-26<br />

Merchandisable Kits and Sizing Information...........................11-28<br />

Terminal Lugs..........................................................................................11-29<br />

PCU Selection..........................................................................................11-30<br />

Interior, Enclosure Options................................................................11-31<br />

Integrated Submetering Panelboard...........................................11-33<br />

Renewal Parts Modular Concept...................................................11-34<br />

Renewal Parts Circuit Breaker Sizing...........................................11-35<br />

Replacement Boxes and Fronts.....................................................11-36<br />

Renewal Parts Product Number Structure ...............................11-38<br />

Renewal Parts – Mounting Hardware .........................................11-41<br />

Renewal Parts – Main Lug Modules;<br />

Neutral and Ground Kits.................................................................11-46<br />

Renewal Parts – Accessories...........................................................11-47<br />

Renewal Parts – Interiors, Boxes and Fronts...........................11-48<br />

Renewal Parts – Type SCP Panelboards ....................................11-49<br />

Renewal Parts – Type CCB and QMR Panelboards ...............11-50<br />

Available Publications .............................................................11-53<br />

Section 12: Switchboards<br />

Evolution Series Switchboards ............................................................12-2<br />

Spectra Series Switchboards................................................................12-5<br />

Commercial Metering Switchboards..................................................12-8<br />

Spectra Integrated Switchboard Solutions.................................12-11<br />

GE GenTower Generator Switchboard............................................12-17<br />

Merchandised and Metering Switchboards—<br />

Jiffy II-Spectra ......................................................................................12-19<br />

Jiffy III Switchboards...........................................................................12-24<br />

Section 13: Busway<br />

Busway Overview ....................................................................................13-2<br />

Busway Short-Circuit Ratings ............................................................13-3<br />

Busway Plug Short-Circuit Ratings..................................................13-4<br />

Spectra Series Busway, Sandwich Bus<br />

Application ..................................................................................................13-5<br />

Aluminum Conductors ..........................................................................13-8<br />

Copper Conductors..............................................................................13-12<br />

Spectra RMS Busway, Sandwich Bus<br />

Circuit Breaker Busway Plugs .........................................................13-20<br />

Circuit Breaker with MicroVersaTrip Plus Trip Units ...........13-25<br />

Spectra Series Busway, Sandwich Bus<br />

Plugs, Fusible, Conversion Kits........................................................13-29<br />

Plug Options ............................................................................................13-33<br />

Outlines, Dimensions and Weights...............................................13-35<br />

Spectra Series Busway, Low Amp<br />

Application and Product Numbers ...............................................13-44<br />

Aluminum Conductors........................................................................13-46<br />

Copper Conductors..............................................................................13-50<br />

Circuit Breaker Busway Plugs .........................................................13-58<br />

Outlines, Dimensions and Weights...............................................13-62<br />

Flex-A-Power Busway<br />

Aluminum Conductors........................................................................13-66<br />

Copper Conductors..............................................................................13-68<br />

Type DH Plugs.........................................................................................13-70<br />

Dimensions...............................................................................................13-73<br />

LW Busway<br />

Replacement Parts, Application.....................................................13-74<br />

4<br />

<strong>BuyLog</strong> <strong>Catalog</strong><br />

www.geindustrial.com Rev. 11/13<br />

Data subject to change<br />

without notice


<strong>BuyLog</strong> <br />

Table of Contents<br />

Replacement Parts, Dimensions....................................................13-76<br />

Type LTG Plug-in, Application ..........................................................13-78<br />

Outlines and Dimensions ..................................................................13-80<br />

Armor-Clad Busway<br />

Transition Sections and Accessories ...........................................13-81<br />

Busway Plugs..........................................................................................13-82<br />

Options and Additions ........................................................................13-87<br />

Flex-A-Power Busway<br />

Types FVA, FVK and LVDP Application.........................................13-88<br />

Busway Plugs..........................................................................................13-91<br />

Outlines and Dimensions ..................................................................13-94<br />

Type DE Busway<br />

Plugs for Obsolete DE Busway........................................................13-95<br />

Section 14: Automatic Transfer Switches<br />

Automatic Transfer Switches...................................................14-2<br />

ATS (Residential) / ZTX Series..............................................................14-4<br />

ATS (Commercial) / ZTG Series...........................................................14-6<br />

ATS (Specification) / ZTS Series.......................................................14-15<br />

ATS (Specification) / ZTE Series.......................................................14-32<br />

ATS (Specification) / ZTED Series....................................................14-34<br />

ATS (Specification) / ZTECT Series..................................................14-36<br />

ATS (Specification) / ZBTE Series ....................................................14-38<br />

ATS (Specification) / ZBTED Series .................................................14-40<br />

ATS (Specification) / ZBTECT Series...............................................14-42<br />

Section 15: Motor Control Centers—Low Voltage<br />

Motor Control Centers Introduction .......................................15-2<br />

EVOLUTION SERIES E9000 Key Benefits ................................15-3<br />

Motor Control Centers Features (SC/MC Program)..............15-4<br />

GE Fastrac Program – MCC Units Quick Selection Guide, E9000<br />

Motor Control Starter Units.................................................................15-5<br />

Motor Control Feeder Units.................................................................15-9<br />

MCC Sections ..........................................................................................15-11<br />

Renewal Parts.........................................................................................15-13<br />

GE Fastrac Program – MCC Units Quick Selection Guide,<br />

CR8000 and Spectra<br />

Motor Control Starter Units..............................................................15-14<br />

Motor Control Feeder Units..............................................................15-18<br />

Renewal Parts.........................................................................................15-19<br />

Section 16: Switchgear — Low Voltage<br />

Introduction.................................................................................16-1<br />

AKD-10 Low-Voltage Switchgear ............................................16-3<br />

AKD-20 Low-Voltage Switchgear ............................................16-3<br />

Arc Vault Arc Flash Protection System.................................16-4<br />

Section 17: Entellisys 5.0 Low-Voltage Switchgear<br />

Layout and sizing .......................................................................17-2<br />

Section 18: Medium Voltage Equipment<br />

MV One Line.................................................................................18-2<br />

Motor Control – Medium Voltage (Limitamp )<br />

Introduction, Features, Types, Options, References................18-3<br />

Specifications, Ratings, Equipment<br />

Reference Publications ......................................................................18-4<br />

Product Scope ...........................................................................................18-5<br />

Introduction<br />

Renewal Parts............................................................................................18-6<br />

Switchgear Type – Power/Vac<br />

Introduction, Publications....................................................................18-8<br />

Power/Vac Vacuum Metalclad Switchgear,<br />

and Breakers...........................................................................................18-9<br />

Characteristics, Symmetrical Rating Basis ...............................18-10<br />

Vacuum Circuit Breakers and Frames ........................................18-11<br />

Section 19: Paralleling Switchgear – Critical Power Products<br />

Paralleling Switchgear...............................................................19-2<br />

Energy Commander ...............................................................................19-3<br />

System Applications...............................................................................19-5<br />

Ordering Information .............................................................................19-6<br />

Section 20: Uninterruptible Power Supplies<br />

Power Quality Services..............................................................20-2<br />

Digital Energy VCL Series ........................................................20-4<br />

Digital Energy VH Series (700-2000 Rackmount and/or Tower)<br />

Description, Applications, Features and Benefits.....................20-5<br />

Technical Specifications and Dimensions....................................20-6<br />

Product Tables – UPS and Battery Packs.....................................20-7<br />

Digital Energy GT Series 120 V (3000 VA Tower)<br />

Description, Applications, Features and Benefits ..................20-10<br />

Technical Specifications and Dimensions.................................20-11<br />

Product Tables – UPS ..........................................................................20-11<br />

Digital Energy GT Series 120 V (3000 19" Rackmount)<br />

Description, Applications, Features and Benefits ..................20-12<br />

Technical Specifications and Dimensions.................................20-13<br />

Product Tables – UPS and Battery Packs ..................................20-13<br />

Digital Energy GT Series (5kVA and 6kVA Tower/Rackmount)<br />

Description, Features and Benefits ..............................................20-14<br />

Technical Specifications and Dimensions.................................20-15<br />

Product Tables – UPS and Battery Packs ..................................20-16<br />

Digital Energy GT Series (8kVA and 10kVA Tower/Rackmount)<br />

Description, Features and Benefits ..............................................20-17<br />

Technical Specifications and Dimensions.................................20-18<br />

Product Tables – UPS and Battery Packs ..................................20-19<br />

Digital Energy LP11U Series 208 V (Single-Phase 5-10 kVA)<br />

Description, Features and Benefits ..............................................20-20<br />

Technical Specifications and Dimensions.................................20-21<br />

Product Tables – UPS and Battery Packs ..................................20-22<br />

Digital Energy LP33U Series 208 V (Three-Phase 10-100 kVA)<br />

Description, Features and Benefits ..............................................20-24<br />

Technical Specifications and Dimensions.................................20-25<br />

Product Tables – UPS and Battery Cabinets............................20-26<br />

Digital Energy SG Series 480 V (Three-Phase 10-750 kVA)<br />

Description, Features and Benefits ..............................................20-31<br />

Technical Specifications and Dimensions (10-150 kVA) .....20-33<br />

Product Tables (10-150 kVA) –UPS, Battery Cabinets,<br />

Transformers and Bypass Panels...............................................20-33<br />

Technical Specifications and Dimensions (225-300 kVA) ..20-40<br />

Product Tables (225-300 kVA) ) –UPS, Battery Cabinets,<br />

Transformers and Bypass Panels .............................................20-40<br />

Technical Specifications and Dimensions (400-500 kVA) .....20-43<br />

Product Tables (400-500 kVA) –UPS, Battery Cabinets,<br />

Transformers and Bypass Panels .............................................20-43<br />

Software and Connectivity Products (10-500 kVA) ...............20-45<br />

Spare Parts, Options and Accessories (10-500 kVA) ............20-46<br />

Rev. 11/13<br />

Data subject to change<br />

without notice<br />

www.geindustrial.com <strong>BuyLog</strong> <strong>Catalog</strong><br />

5


<strong>BuyLog</strong> <br />

Table of Contents<br />

Services and Commissioning (10-500 kVA) ..............................20-47<br />

Digital Energy TLE Series (225-1500 kW)<br />

Description, Features and Benefits ..............................................20-48<br />

Section 21: Telecommunication Hardware<br />

Introduction.................................................................................21-1<br />

Fiber Closure Hardware ............................................................21-2<br />

Cable Location Surge Protectors.............................................21-4<br />

Section 22: Relays and Meters<br />

Protection & Control<br />

Protection & Control Product Families ...................................22-3<br />

UR Family Protection System............................................................22-4<br />

SR Enhanced Drawout Protection System...............................22-13<br />

650 Mid-range Protection System...............................................22-14<br />

SR 3-Series Protection .......................................................................22-15<br />

MII Modular Protection System .....................................................22-17<br />

Generator Protection...............................................................22-22<br />

Generator Protection Selector Guide .........................................22-23<br />

G60 Medium to Large Generator Protection ..........................22-24<br />

G30 Combined Generator and Transformer Protection....22-26<br />

489 Small to Medium Generator Protection ...........................22-28<br />

G650 Distributed Generator Protection ....................................22-30<br />

W650 Wind Turbine Generator Protection ..............................22-32<br />

MIG II Small Generator Protection ...............................................22-34<br />

MIW II Directional Power/Loss of Field Protection ...............22-35<br />

Transformer Protection...........................................................22-36<br />

Transformer Protection Selector Guide.....................................22-37<br />

T60 Medium to Large Transformer Protection ......................22-38<br />

T35 6 Winding Transformer Protection.....................................22-40<br />

745 Medium to Large Transformer Protection ......................22-42<br />

345 Small to Medium Transformer Protection.......................22-44<br />

Transmission Line Protection ................................................22-46<br />

Transmission Protection Selector Guide...................................22-48<br />

L90 Line Current Differential Protection....................................22-50<br />

L60 Phase Comparison Protection ..............................................22-52<br />

L30 Line Current Differential System..........................................22-54<br />

D90 Plus Sub-Cycle Distance Protection........................................22-56<br />

D60 Distance Protection...................................................................22-58<br />

D30 Backup Distance Protection..................................................22-60<br />

Bus Protection...........................................................................22-62<br />

Bus Protection Selector Guide .......................................................22-63<br />

B95 Plus Busbar Protection ..................................................................22-64<br />

B90 Multiple Section Busbar Protection....................................22-66<br />

B30 Busbar Protection.......................................................................22-68<br />

MIB High Impedance Busbar Protection ..................................22-70<br />

HID High Impedance Auxiliary Protection Module .............22-71<br />

Distribution Feeder Protection ..............................................22-72<br />

Distribution Feeder Protection Selector Guide ..........................22-74<br />

F60 Feeder Protection with Hi-Z Detection .............................22-76<br />

F35 Multiple Feeder Protection .....................................................22-78<br />

750/760 Comprehensive, Draw Out Feeder Protection ....22-80<br />

F650 Feeder/Bay Protection...........................................................22-82<br />

350 50/51 Feeder Protection..........................................................22-84<br />

A60 Arc Flash Detection ...................................................................22-86<br />

735/737 Three-Phase and Ground Feeder Protection.......22-87<br />

MIF II Economical Feeder Protection with Recloser ............22-88<br />

FM2 Low Voltage Feeder Protection...........................................22-89<br />

Introduction<br />

Motor Protection ......................................................................22-90<br />

Motor Protection Selector Guide ..................................................22-92<br />

M60 Medium to Large Motor Protection...................................22-94<br />

469 Medium to Large Motor Protection....................................22-96<br />

369 Small to Medium Motor Protection ....................................22-97<br />

369 Draw-out Motor Protection....................................................22-99<br />

339 Small to Medium Motor Protection..................................22-101<br />

269 Plus Small to Medium Motor Protection .............................22-103<br />

239 Small to Medium Motor Protection..................................22-104<br />

MM300 Low Voltage Motor Management...........................22-105<br />

MM2 Low Voltage Motor Management..................................22-107<br />

SPM Synchronous Motor Protection.........................................22-109<br />

Specialized Protection, Control and Recording................22-110<br />

C60 Breaker Monitoring and Control .......................................22-111<br />

C30 I/O Logic Controller.................................................................22-113<br />

N60 Network Stability and Synchrophasor Measurement .....22-115<br />

C70 Capacitor Bank Protection ..................................................22-117<br />

C90 Plus Automation Control System...........................................22-119<br />

HardFiber 61850 Process Bus.....................................................22-121<br />

MIV II Voltage/Frequency Protection .......................................22-123<br />

MIN II Ground Protection ...............................................................22-124<br />

RRTD Remote RTD Metering Module for the 369 ...............22-125<br />

DDFR Distributed Digital Fault Recorder ................................22-126<br />

Single Function Protection Relays ......................................22-128<br />

Single Function Auxiliary Relays .........................................22-138<br />

Substation Gateways and RTU ............................................22-140<br />

D400 Advanced Substation Gateway......................................22-140<br />

D20MX Substation Controller ......................................................22-142<br />

D.20 RIO Distributed I/O Controller ...........................................22-144<br />

D25 Substation Controller.............................................................22-145<br />

Metering<br />

Digital Metering......................................................................22-147<br />

Digital Metering Family Selection Guide ................................22-148<br />

PQM II Power Quality Meter .........................................................22-149<br />

EPM 9900 Advanced Power Quality Meter............................22-150<br />

EPM 9800 Socket Mounted Power Quality Meter ..............22-152<br />

EPM 9000 Advanced Power Quality Meter............................22-154<br />

EPM 7000 Revenue Class PQ Meter .........................................22-156<br />

EPM 6010 Building Automation Meter ....................................22-158<br />

EPM 6000 Revenue Class Power Meter ..................................22-159<br />

EPM 2200 Power Meter ..................................................................22-160<br />

EPM 4500 Multi-tenant Sub-Metering System ....................22-161<br />

EPM 1500 Single-point Sub-Metering System.....................22-164<br />

EPM 7100 Energy Submeter w/WIFI and Logging ............22-166<br />

EPM 6100 Energy Submeter w/WIFI ........................................22-167<br />

GE Meter in a Box (MIB) ..................................................................22-168<br />

Communications<br />

Multiplexers.............................................................................22-170<br />

Multiplexer Family Overview........................................................22-171<br />

JMUX SONET Multiplexer ...............................................................22-174<br />

JMUX T1 Multiplexer.........................................................................22-174<br />

TN1U SDH Multiplexer.....................................................................22-175<br />

TN1Ue SDH Enhanced Multiplexer............................................22-175<br />

VistaNET Network Management Software .........................22-176<br />

MDS Wireless Solutions ..................................................................22-178<br />

Ethernet Switches ..................................................................22-181<br />

Multilink Family Overview..............................................................22-181<br />

ML3000 19” Rack-mounted Managed Switch.....................22-182<br />

6<br />

<strong>BuyLog</strong> <strong>Catalog</strong><br />

www.geindustrial.com Rev. 11/13<br />

Data subject to change<br />

without notice


<strong>BuyLog</strong> <br />

Table of Contents<br />

ML2400 19” Rack-mounted Managed Switch.....................22-184<br />

ML1600 9” Panel-mounted Managed Switch......................22-185<br />

ML600 Unmanaged Compact Switch .....................................22-186<br />

Media & Protocol Converters...............................................22-187<br />

MultiNet RS485 to Ethernet........................................................22-188<br />

Media & Protocol Converters.......................................................22-189<br />

Power Sensing<br />

Instrument Transformers .....................................................22-190<br />

Current Transformers......................................................................22-190<br />

Low Voltage Potential Transformers........................................22-193<br />

Bushing Current Transformers ...................................................22-194<br />

Medium Voltage Instrument Transformers ..........................22-194<br />

Control Power Transformers........................................................22-195<br />

Current Transducers ........................................................................22-195<br />

IEC Rated Instrument Transformers.........................................22-196<br />

Accessories..............................................................................22-197<br />

Switches<br />

SB-1, SB-9, Series 95........................................................................22-197<br />

SB-10, SBM, FT, RT Test Switch....................................................22-198<br />

Test Equipment<br />

515, PK2, XCA, XLA............................................................................22-199<br />

Terminal Blocks<br />

116B407, EB-25, EB-26, EB-27, IKU, EB-1, EB-2, EB-4......22-199<br />

Indicator Lights<br />

ET-16, ET-16 LED, ET-17 .................................................................22-199<br />

Test Equipment<br />

RTT Desktop Test Set .......................................................................22-200<br />

Software<br />

EnerVista Suite......................................................................22-202<br />

Launchpad Device Setup & Document Management.....22-203<br />

Viewpoint Engineer Control Logic Creator &<br />

Commissioning Toolset ................................................................22-206<br />

Viewpoint Maintenance Device Health &<br />

Security Reporting ..........................................................................22-210<br />

Viewpoint Monitoring & Data Recording................................22-214<br />

Integrator OPC/DDE Communications Server.....................22-224<br />

Value Added Services<br />

Value Added Services ............................................................22-227<br />

Energy Management Systems....................................................22-227<br />

Advanced Training Services.........................................................22-229<br />

Consulting Services ..........................................................................22-231<br />

Packaged Solutions..........................................................................22-233<br />

Product Upgrades And Replacements<br />

Product Upgrades and Replacements ...............................22-234<br />

Section 23: Meters and Instrument Transformers<br />

Three-Phase Metering ...............................................................23-2<br />

Instrument Transformers, 600 Volt.........................................23-4<br />

Instrument Transformers, 2.5-69 kV.......................................23-5<br />

Section 24: Capacitors, Arresters and Harmonic Filters<br />

Line/Load Reactors—up to 600V......................................................24-2<br />

Line/Load Reactors—Three-phase Reactors..............................24-4<br />

Matrix Series D Harmonic Filters .....................................................24-6<br />

Protective Capacitors for AC Rotating Machines...................24-11<br />

Fixed Motor and Pump Capacitors...............................................24-13<br />

Introduction<br />

Fixed Low Voltage Power Factor Correction<br />

Capacitors ............................................................................................24-15<br />

Fixed Low Voltage Power Factor Correction<br />

with Harmonic Filter Equipment.................................................24-24<br />

Automatic Fast-Switching LV Power<br />

Factor Correction Capacitors.......................................................24-26<br />

Automatic LV Power Factor Correction Capacitors..............24-30<br />

Automatic LV Power Factor Correction<br />

Capacitors and Harmonic Filter Equipment .........................24-33<br />

Active Harmonic Filter .......................................................................24-35<br />

Fixed MV Power Factor Correction Capacitors.......................24-37<br />

High Voltage Capacitor Units, Singleand<br />

Three-Phase................................................................................24-40<br />

High Voltage Pole-Mounted, Open Stack-Rack<br />

and Metal Enclosed Equipment ..................................................24-44<br />

OEM High Energy Surge Protectors..............................................24-46<br />

Tranquell ‚ Motor Surge Protectors—<br />

Motor and Generator Surge Protection Equipment ..........24-48<br />

Secondary Surge Arresters and Protective Capacitors<br />

Series 9L15F .........................................................................................24-49<br />

HV Station Arresters—Polymer and Porcelain.........................24-50<br />

HV Intermediate Arresters—Polymer...........................................24-58<br />

Station and Intermediate Arresters—Outline Drawings .....24-62<br />

Station and Intermediate Class Arrestors—Accessories ....24-63<br />

Distribution and Riser Pole Arresters...........................................24-64<br />

Section 25: Distribution Transformers–Medium<br />

and High Voltage<br />

Substation Transformers ..........................................................25-2<br />

Three-phase Padmounted Transformers...............................25-4<br />

Single-Phase Pole-Mounted Transformers............................25-6<br />

Network Transformers ..............................................................25-7<br />

Voltage Regulators<br />

VR-1................................................................................................................25-8<br />

Bushing Potential Devices......................................................25-11<br />

Section 26: DC Power Systems<br />

CPS6000 Cabinet Power System..............................................26-2<br />

Slimline Power System ..............................................................26-3<br />

Section 27: RV Power Pedestals<br />

Introduction.................................................................................27-2<br />

Tables............................................................................................27-3<br />

Accessories ..................................................................................27-4<br />

Dimensions and Weights ..........................................................27-5<br />

Wire Range Tables .....................................................................27-7<br />

Section 28: GE Publication Index<br />

Publications Index ......................................................................28-1<br />

Section 29: Time Current Curves and Outline Drawings<br />

Time Current Curves..................................................................29-1<br />

Outline Drawings........................................................................29-5<br />

Section 30: Product Index<br />

Product Index ..............................................................................30-1<br />

Rev. 11/13<br />

Data subject to change<br />

without notice<br />

www.geindustrial.com <strong>BuyLog</strong> <strong>Catalog</strong><br />

7


<strong>BuyLog</strong> <br />

888-GE4-SERVice<br />

Electrical Service Solutions for Industry<br />

Introduction<br />

Need a knowledgeable service provider who’s there when needed most? Calling 888-GE4-SERVice connects you with<br />

over 100 years of power system expertise, including generation, delivery, utilization and control.<br />

Meet Day-to-Day Challenges Without Dedicated Resources<br />

Looking for an efficient way to quickly resolve equipment problems or to cost-effectively manage ongoing service<br />

needs? GE’s field service professionals are expertly trained on GE and non-GE equipment in a wide range of applications,<br />

which gives them the knowledge they need to function as an immediate extension of your team. From installation to<br />

start-up and commissioning through training, maintenance and repair, GE can support you in every stage of your power<br />

system’s lifecycle.<br />

Global Reach at a Moment’s Notice<br />

GE’s global network of service professionals is available 24 hours a day, seven days a week. With over 5,000 service<br />

professionals and 60 repair facilities strategically located around the world, GE can help you address emergencies and<br />

short turn-around requests in a single call. Our on-demand response capability, extended inventory and knowledgeable<br />

staff can help minimize downtime and improve profitability.<br />

Emergency response and disaster recovery services are also available:<br />

• Assessment of equipment system and fast development of recovery plans<br />

• Backup personnel ranging from craft labor to specialty engineers<br />

• Emergency power needs<br />

• Site management and logistics<br />

Expand Your Portfolio to Include Specialty Support Services<br />

GE can provide access to power system specialists on an as-needed basis. With over 100 years of power system<br />

knowledge in a wide range of industries, GE has the in-house expertise to deliver an added level of service. Help maximize<br />

a power system, extend equipment life or ensure compliance with industry and regulatory standards through service<br />

offerings such as:<br />

• Short-circuit, load flow, harmonic and protective relay studies<br />

• Arc-flash hazard analyses<br />

• Remote monitoring & diagnostics<br />

• Predictive maintenance services<br />

When you need onsite field service support call your local sales team or<br />

888-GE4-SERVice<br />

International or toll calls: 540-378-3280<br />

8<br />

<strong>BuyLog</strong> <strong>Catalog</strong><br />

www.geindustrial.com Rev. 11/13<br />

Data subject to change<br />

without notice


<strong>BuyLog</strong> <br />

Parts Super Center<br />

Introduction<br />

Parts Super Center is your one-stop source for genuine renewal parts for mature GE products lines and<br />

many current products. It also offers a variety of cost-effective services and solutions:<br />

• Factory tech support – factory expertise remains even when factories do not<br />

• 24-hour emergency service<br />

• Quick access to more than 300,000 part numbers<br />

• Over $30 million dollars in inventory<br />

• Fast turnaround - stock items shipped same day order is received<br />

• Inventory management programs, including JIT<br />

• Web-based electronic ordering<br />

• On-line publications and parts catalogs<br />

• Dedicated, cross-functional product teams<br />

• Customer satisfaction driven by six sigma quality<br />

Parts Super Center parts coverage<br />

Switchgear<br />

Philadelphia Breaker Plant<br />

• Magneblast Parts<br />

• OCB Oil Circuit Breaker Parts<br />

• ATB Circuit Breaker Parts<br />

Mebane Plant<br />

• 7700/8000 Line Motor Control Center Parts<br />

• Limitamp Starter Parts<br />

Burlington Switchgear Plant<br />

• AK/AKR Breaker Parts<br />

• PowerVac Breaker Parts<br />

• WavePro Breakers<br />

• Entellisys Breaker Parts & Test Kits<br />

Mature Designs<br />

• TEL Breakers<br />

• TEML Breakers<br />

• TFL Breakers<br />

• TLB4 Breakers<br />

• TJL, TJH Breakers<br />

• TKL, TKH Breakers<br />

• TJ4V, THJ4V, TJL4V Breakers<br />

• TK4V, TKL4V Breakers<br />

• Power Break I Breakers<br />

and Accessories<br />

Transformers<br />

Rome Plant<br />

• Primary Substation Parts<br />

• Load Tap Changers (Complete units and<br />

parts)<br />

• Replacement Units<br />

Hickory Plant<br />

• Bushing Potential Devices - Complete units<br />

• Inductrol Regulator Complete units and parts<br />

• Step Voltage Regulator Parts<br />

Pittsfield Plant<br />

• Primary Substation Parts<br />

• Load Tap Changer Parts<br />

Drive Systems<br />

Salem Plant<br />

• Rainbow <strong>Catalog</strong> Components<br />

• Drive Boards<br />

1-800-645-1601<br />

www.PartsDirect.GE.com<br />

General Purpose Control<br />

• CR7 Line Push Buttons<br />

• 080 Line Push Buttons<br />

• Light Tower Products<br />

• Palm Switch<br />

• 3S7505 Series Photoelectric Controls<br />

• CR360ML2 Lighting Contactors and<br />

replacement contact blocks & coil kits<br />

Rev. 11/13<br />

Data subject to change<br />

without notice<br />

www.geindustrial.com <strong>BuyLog</strong> <strong>Catalog</strong> 9


<strong>BuyLog</strong> <br />

Auto-Updating Product Information<br />

The GE Smart <strong>Catalog</strong><br />

Introduction<br />

One-Stop Access to <strong>Catalog</strong>s<br />

Get quick access to detailed product features, product numbers,<br />

specifications, dimensions, pricing and accessories. The following<br />

catalogs are available:<br />

• Control <strong>Catalog</strong> — General Purpose Control Components<br />

• <strong>BuyLog</strong> — Low and Medium Voltage Components and<br />

Equipment<br />

Download both catalogs or just the one you need. Once downloaded,<br />

instantly access product information on- or offline.<br />

Automatic <strong>Catalog</strong> Updates<br />

Having the latest GE catalog information has never been quicker<br />

or easier. When used online, you will be notified automatically<br />

when updates are available.<br />

Learn more about how the GE Smart <strong>Catalog</strong> works.<br />

Go to energy.gecatalogs.com<br />

10<br />

<strong>BuyLog</strong> <strong>Catalog</strong><br />

www.geindustrial.com Rev. 11/13<br />

Data subject to change<br />

without notice


Load Centers and Circuit Breakers<br />

Section 1<br />

Q-Line Circuit Breakers– Product Features and Benefits........1-2<br />

PowerMark Gold Load Centers—<br />

Product Features and Benefits ........................................................1-3<br />

PowerMark Gold and Plus Load Centers—<br />

Product Number Guides......................................................................1-4<br />

Q-Line Plug-in Circuit Breakers............................................................1-5<br />

Special Purpose Circuit Breakers........................................................1-6<br />

PowerMark Gold and Plus Single-Phase Load Centers—<br />

Main Lug Convertible to Main Breaker.........................................1-9<br />

Main Breaker Factory Installed .....................................................1-12<br />

PowerMark Plus Three-Phase Load Centers—<br />

Main Circuit Breakers or Main Lugs Factory Installed .......1-14<br />

PowerMark Gold Load Centers—Specialty Panels...................1-17<br />

PowerMark Gold Meter Socket Load Centers ............................1-18<br />

Field Installed Accessories...................................................................1-24<br />

Wiring Diagrams ......................................................................................1-30<br />

Load Centers and Meter Socket Load Centers—<br />

Knockouts................................................................................................1-37<br />

Rev. 11/13<br />

Data subject to change<br />

without notice<br />

www.geindustrial.com<br />

<strong>BuyLog</strong> <strong>Catalog</strong><br />

1-1


Load Centers and Circuit Breakers<br />

Q-Line Circuit Breakers<br />

Reliability and Economy<br />

Section 1<br />

Special Purpose Circuit Breakers<br />

—PowerMark Gold Main Circuit Breakers<br />

—Arc Fault Circuit Interrupter<br />

—Dual Function GFCI/AFCI Ground Fault<br />

& Combination Arc Fault Circuit Breaker<br />

—Ground Fault with Self-Test Feature<br />

—Ground Fault with Equipment Protection<br />

—Switching Neutral<br />

—HID Lighting Breaker<br />

—High Magnetic Breaker<br />

—Molded Case Switch<br />

—Surge Arrester<br />

—TQ Breaker<br />

Copper stabs, tin-plated for corrosion resistance,<br />

make the connection reliable and permanent.<br />

Heat-resistant thermoset cases and covers add<br />

stability and structural rigidity.<br />

Trips are easy to spot because handles trip to the<br />

center position.<br />

The dedicated calibration screw is cemented (not<br />

simply papered over) to prevent shifting. The result is<br />

stable calibration for optimum trip performance.<br />

At 1/2”, THQP breakers are half the width of standard breakers, permitting the use of smaller<br />

load centers that save money and space in both new construction and service upgrades. They<br />

feature the same high-performance design, and meet the same stringent standards as other Q-<br />

Line breakers. Our 1” THQL will remain the breaker of choice for many contractors. In applications<br />

where space and cost are not critical, they’re an excellent choice. But when size and money<br />

are driving considerations, THQP breakers are the smart choice.<br />

Enclosed circuit<br />

breakers make it<br />

easy and efficient<br />

to install exterior<br />

main breakers.<br />

Maximum protection<br />

against all-too-common<br />

electrical fires comes<br />

from the new technology<br />

built into GE’s arc fault<br />

circuit interrupters (AFCIs).<br />

With its ability to detect<br />

and interrupt arcing<br />

caused by damaged wire<br />

insulation or a frayed extension cord, the AFCI takes<br />

home and family protection to a new, higher level.<br />

THQLSURGE surge<br />

arresters are easy to<br />

install and protect the<br />

whole house – computers,<br />

fax machines, televisions,<br />

stereos, VCRs and<br />

other sensitive electronic<br />

equipment – from<br />

destructive surges.<br />

The NEC requires ground fault protection of receptacles outdoors and<br />

in garages, bathrooms and spa areas. These ground fault circuit<br />

interrupters eliminate the need for separate GFCI receptacles, protect<br />

against short circuits and overloads, and prevent shock by detecting<br />

very low levels of current leaks and immediately shutting off power to<br />

the circuit.<br />

1-2 <strong>BuyLog</strong> <strong>Catalog</strong> www.geindustrial.com<br />

Rev. 11/13<br />

Data subject to change<br />

without notice


Load Centers and Circuit Breakers<br />

PowerMark Gold Load Centers<br />

Highest Quality and Convenience<br />

PowerMark Gold load centers lower your costs by making installation<br />

faster and easier, increasing application flexibility and reducing<br />

inventory requirements. At the same time, they deliver obvious<br />

and significant advances in design, function and quality.<br />

—UL Listed (Panelboards No. 67)<br />

—Suitable for Use as Service Entrance Equipment when installed<br />

in accordance with National Electrical Code<br />

—60°C/75°C Conductor Rating<br />

—Single phase, 40-225A, 2-42 circuits<br />

—Main lug models field convertible to main breaker<br />

—Main breaker 22kAIC standard - factory installed<br />

—All load centers top or bottom feed<br />

—Indoor and outdoor rated enclosures<br />

—Indoor fronts combination surface/flush<br />

—Copper bus with tin plating standard 1<br />

—Split neutrals extend the full length of the interior for ease of wiring<br />

—Entire main lug line converts easily to main breaker<br />

—Combination surface/flush front with spring-reinforced pan<br />

—Combination slotted/Robertson square-drive screws on neutral, 2<br />

ground, front and breaker lugs<br />

—Front packed in inner carton for added protection<br />

—Field installable feed-through lugs up to 200A<br />

—Straight-through main wiring<br />

—Main breaker is clearly marked and circuit numbers are stamped<br />

on front<br />

—Isolated ground bar is available<br />

—Compact box maintains optimum wire-bending space<br />

One-piece interior<br />

removes and<br />

reinstalls easily<br />

Full-length neutrals<br />

are easier to wire, 2<br />

reducing installation<br />

time and cost<br />

Minimum 100%<br />

neutral<br />

terminations<br />

Sturdy copper bus<br />

and galvanized box<br />

increase durability<br />

and reliability<br />

Accepts GE Q-Line branch<br />

circuit breakers, including<br />

GE’s exclusive 1/2" THQPs<br />

Section 1<br />

Main breaker configuration<br />

allows top or bottom<br />

feed without modification<br />

Combination<br />

slotted/Robertson<br />

square-drive<br />

speeds screw<br />

wiring<br />

All holes rated<br />

for 14-4 wire<br />

100% rated<br />

split neutral<br />

on each side 2<br />

Tie bar may be<br />

removed to split<br />

neutral/ground<br />

Packaging features comprehensive<br />

selection and application data.<br />

Fronts are packed in inner cartons<br />

for added protection during shipment<br />

and at the job site.<br />

A complete family of meter socket load centers — ring style<br />

and ringless, wide and narrow, meter mains, farm panels and<br />

more — deliver specialized solutions for special situations.<br />

The PowerMark Gold<br />

line includes a wide<br />

range of outdoor as<br />

well as indoor units.<br />

Accessories and Options<br />

—Door lock and handle<br />

—Equipment ground kits<br />

—Sub-feed and feed-thru lugs<br />

—Front filler plates<br />

—Handle lock and ties<br />

Main lug load centers offer an economical<br />

solution for subpanels and similar applications.<br />

All main lug units 125A and above convert easily<br />

to main breaker.<br />

—Hardware kits<br />

—Main breaker retainers<br />

—Neutral kits<br />

—Universal raintight hubs<br />

1 Three-phase PowerMark Plus load centers have aluminum bus with copper breaker<br />

mounting stabs.<br />

2 16 circuit and above.<br />

GE’s residential load centers reach into<br />

commercial applications as well, with riser<br />

panels, auxiliary gutters, three-phase units<br />

with standard 22kAIC ratings, and all the<br />

accessories needed to complete the job.<br />

Safety accessories – convenient and easy to install<br />

—THQLSURGE whole house surge protector<br />

—Arc fault circuit interrupter breaker, 1- or 2-pole<br />

—Ground fault circuit interrupter breaker, 5mA and 30mA<br />

—Generator transfer panel – 30A or 60A, indoor or outdoor<br />

—GE AC disconnects<br />

Rev. 11/13<br />

Data subject to change<br />

without notice<br />

www.geindustrial.com<br />

<strong>BuyLog</strong> <strong>Catalog</strong><br />

1-3


Load Centers and Circuit Breakers<br />

PowerMark Gold and Plus Load Centers<br />

Product Number Guides<br />

Section 1<br />

Product Number Guide for Load Centers<br />

(Product number for illustrative purposes only)<br />

T<br />

M<br />

42<br />

4 20 C CU B<br />

GE Identification<br />

Type<br />

M = Main breaker<br />

L = Main lug<br />

LM = Convertible<br />

PL = Main lug (Thermoplastic)<br />

Maximum Number 1" Spaces<br />

2, 4, 6…42<br />

Insert for 3-Phase 4-Wire<br />

Load Centers<br />

Insert for Specials<br />

G or T = Factory installed ground bar<br />

B = Bottom feed main breaker<br />

FL = Factory installed feed-through lugs<br />

D = Optional door for 6-8 circuit panel.<br />

(Doors standard on all units 12<br />

circuits or greater)<br />

W = White Front<br />

Insert for PowerMark Gold<br />

CU = Copper Bus<br />

42 = Copper Bus Full 42 circuit panel<br />

Enclosure Type<br />

C = Combination surface/flush<br />

F = Flush<br />

S = Surface<br />

R = Outdoor<br />

Bus Ampere Rating<br />

40 = 40 Amps 20 = 200 Amps<br />

70 = 70 Amps 22 = 225 Amps<br />

10 = 100 Amps 30 = 300 Amps<br />

12 = 125 Amps 40 = 400 Amps<br />

15 = 150 Amps 60 = 600 Amps<br />

Product Number Guide for Q-Line Plug-in Circuit Breakers<br />

(Product number for illustrative purposes only)<br />

T<br />

H<br />

QL<br />

1 1* 15<br />

GFT<br />

GE Identification<br />

Interrupting Rating<br />

H = 10kAlC<br />

HH = 22kAlC<br />

X = 65kAlC<br />

Type<br />

QL = 1" plug-in<br />

QP = 1/2" plug-in<br />

QB = 1" bolt-on<br />

Poles (1, 2, 3)<br />

Voltage<br />

1 = 120/240V<br />

2 = 240V<br />

Ampere Rating<br />

Ground Fault/Arc Fault Circuit Interrupter<br />

AF2 = 1- & 2-pole Combination Arc Fault<br />

Circuit Interrupter<br />

GFEP = 1- & 2-pole Ground Fault with<br />

Equipment Protection Interrupter–30 mA<br />

GFT = 1- & 2-pole Ground Fault<br />

with Self-Test Feature Interrupter - 5 mA<br />

DF = 1-pole Dual Function GFCI/AFCI Ground Fault<br />

& Combination Arc Fault Circuit Interrupter<br />

*Omit character for THQP breakers, which are all 120/240V.<br />

1-4 <strong>BuyLog</strong> <strong>Catalog</strong> www.geindustrial.com<br />

Rev. 11/13<br />

Data subject to change<br />

without notice


Load Centers and Circuit Breakers<br />

Q-Line Plug-in Circuit Breakers<br />

UL Listed (Molded Case Circuit Breakers No. 489)<br />

Federal Government Specification Qualified (WC-375B)<br />

60°C / 75°C Conductor Rating<br />

Quick Make, Quick Break<br />

Box Type Terminals<br />

Section 1<br />

Q-Line Plug-in Circuit Breakers Specifications<br />

THQP130<br />

THQP230<br />

THQL1120<br />

Wire Size AWG/kcmil 1<br />

Breaker Type Ampere Rating Cu Al<br />

15-25 14-8 12-8<br />

THQP<br />

30-50 8-4 8-4<br />

15-30 14-8 12-8<br />

THQL<br />

35-60 8-3 8-3<br />

THHQL<br />

70-100 6-1/0 4-1/0<br />

TXQL<br />

110-125 2-2/0 2-2/0<br />

1 Solid or stranded for 14-10 AWG<br />

THQL2140<br />

THQL32015<br />

Q-Line Plug-in Circuit Breakers<br />

10,000AIC 22,000AIC 65,000AIC<br />

Type THQP 1/2-inch Module Type THQL 1-inch Module Type THHQL 1-inch Module Type TXQL 1-inch Module<br />

120/240 Vac 120/240 Vac 120/240 Vac 240 Vac 120/240 Vac 240 Vac 120/240 Vac<br />

Ampere Product Product Product Product Product Product<br />

Rating Number Number Number Number Number Number<br />

Single Pole 1<br />

15 2 THQP115 THQL1115 – THHQL1115 – TXQL1115<br />

20 2 THQP120 THQL1120 – THHQL1120 – TXQL1120<br />

25 THQP125 THQL1125 – THHQL1125 – TXQL1125<br />

30 THQP130 THQL1130 – THHQL1130 – TXQL1130<br />

35 THQP135 THQL1135 – THHQL1135 – –<br />

40 THQP140 THQL1140 – THHQL1140 – –<br />

45 THQP145 THQL1145 – THHQL1145 – –<br />

50 THQP150 THQL1150 – THHQL1150 – –<br />

Std. Pkg. 5 cartons of 20 5 cartons of 10 5 cartons of 10 5 cartons of 10<br />

Two-Pole 3 : Incorporates Internal Common Trip Bar<br />

15 THQP215 THQL2115 THQL22015 4 THHQL2115 THHQL22015 4 TXQL2115<br />

20 THQP220 THQL2120 THQL22020 4 THHQL2120 THHQL22020 4 TXQL2120<br />

25 THQP225 THQL2125 THQL22025 4 THHQL2125 THHQL22025 4 TXQL2125<br />

30 THQP230 THQL2130 THQL22030 4 THHQL2130 THHQL22030 4 TXQL2130<br />

35 THQP235 THQL2135 THQL22035 4 THHQL2135 THHQL22035 4 –<br />

40 THQP240 THQL2140 THQL22040 4 THHQL2140 THHQL22040 4 –<br />

45 THQP245 THQL2145 THQL22045 4 THHQL2145 THHQL22045 4 –<br />

50 THQP250 THQL2150 THQL22050 4 THHQL2150 THHQL22050 4 –<br />

60 – THQL2160 THQL22060 4 THHQL2160 THHQL22060 4 –<br />

70 – THQL2170 THQL22070 4 THHQL2170 THHQL22070 4 –<br />

80 – THQL2180 THQL22080 4 THHQL2180 THHQL22080 4 –<br />

90 – THQL2190 THQL22090 4 THHQL2190 THHQL22090 4 –<br />

100 – THQL21100 THQL22100 4 THHQL21100 THHQL22100 4 –<br />

110 – THQL21110 – THHQL21110 – –<br />

125 – THQL21125 – THHQL21125 – –<br />

Std. Pkg. 5 cartons of 10 5 cartons of 5 5 cartons of 5 5 cartons of 5 5 cartons of 5 5 cartons of 5<br />

Three-Pole 3 : Incorporates Internal Common Trip Bar<br />

15 – – THQL32015 – THHQL32015 TXQL32015<br />

20 – – THQL32020 – THHQL32020 TXQL32020<br />

25 – – THQL32025 – THHQL32025 TXQL32025<br />

30 – – THQL32030 – THHQL32030 TXQL32030<br />

35 – – THQL32035 – THHQL32035 –<br />

40 – – THQL32040 – THHQL32040 –<br />

45 – – THQL32045 – THHQL32045 –<br />

50 – – THQL32050 – THHQL32050 –<br />

60 – – THQL32060 – THHQL32060 –<br />

70 – – THQL32070 – THHQL32070 –<br />

80 – – THQL32080 – THHQL32080 –<br />

90 – – THQL32090 – THHQL32090 –<br />

100 – – THQL32100 – THHQL32100 –<br />

Std. Pkg. 5 cartons of 3 5 cartons of 3 5 cartons of 3<br />

1 UL Listed as HACR (heating, air conditioning and refrigeration).<br />

2 UL Listed as SWD (switching duty). Suitable for 120 volts ac fluorescent lighting<br />

loads.<br />

3 15-100 amp UL Listed as HACR (heating air conditioning and refrigeration).<br />

4 Required for three-phase and High Leg Delta Systems only.<br />

References:<br />

Accessories Pages 1-24 thru 1-29<br />

Auxiliary Switches and Shunt Trips <strong>BuyLog</strong> pages 6-40 thru 6-42<br />

Rev. 11/13<br />

Data subject to change<br />

without notice<br />

www.geindustrial.com<br />

<strong>BuyLog</strong> <strong>Catalog</strong><br />

1-5


Load Centers and Circuit Breakers<br />

Special Purpose Circuit Breakers<br />

60°C / 75°F Conductor Rating<br />

Box Type Terminals<br />

Quick-Make, Quick-Break<br />

Multi-pole Breakers Incorporate Internal Common Trip<br />

Section 1<br />

Arc Fault 2<br />

UL Listed<br />

Arc-Fault Circuit Interrupters No. 1699<br />

Ampere Rating<br />

1 Pole, 120/240 Volts ac 1<br />

Product Number<br />

10,000 AIC<br />

15 THQL1115AF2<br />

20 THQL1120AF2<br />

22,000 AIC<br />

15 THHQL1115AF2<br />

20 THHQL1120AF2<br />

Std. Pkg. 10 Cartons of 1<br />

As of Jan. 1, 2008, 2005 NEC requires combination AFCI.<br />

1 Combination AFCI compliant with 2008 NEC and later<br />

2 For 2-Pole shared neutral applications use two 1-pole circuit breakers with a handle tie. See DET-719 for more<br />

details on our Arc Fault products.<br />

Dual Function GFCI/AFCI Ground Fault & Combination Arc Fault Circuit Breaker<br />

UL Listed (Available December 2014)<br />

1 Pole, 120 Volts ac<br />

Ampere Rating<br />

Product Number<br />

10,000 AIC<br />

15 THQL1115DF<br />

20 THQL1120DF<br />

22,000 AIC<br />

15 THHQL1115DF<br />

20 THHQL1120DF<br />

Std. Pkg. 10 Cartons of 1<br />

Ground Fault with Self-Test Feature<br />

cULus<br />

Ground Fault Circuit Interrupters UL943 ed5 (5 milliamperes)<br />

10,000 AIC<br />

22,000 AIC<br />

3 UL & CSA<br />

1-Pole, 120 Volts ac<br />

2-Pole, 120/240 Volts ac<br />

Ampere Rating Product Number Product Number<br />

15 THQL1115GFT THQL2115GFT<br />

20 THQL1120GFT THQL2120GFT<br />

25 THQL1125GFT THQL2125GFT<br />

30 THQL1130GFT THQL2130GFT<br />

40 – THQL2140GFT 3<br />

50 – THQL2150GFT 3<br />

15 THHQL1115GFT –<br />

20 THHQL1120GFT –<br />

25 THHQL1125GFT –<br />

30 THHQL1130GFT –<br />

PowerMark Gold Main Circuit Breakers for use with 150A-225A PowerMark Gold Load<br />

Centers (Includes mounting base)<br />

UL Listed.<br />

Description Ampere Rating Product Number Lug Size<br />

100 THQMV100D<br />

125 THQMV125D<br />

Main Circuit Breaker Kits 150 THQMV150D 1-300 (cu),<br />

22,000 AIC 175 THQMV175D 2/0-300<br />

200 THQMV200D<br />

225 THQMV225D<br />

Note: Wire bending rules affect allowed wire sizes when THQMV breakers are installed in an enclosure. For load<br />

centers, the wire range will be on the rating label. In addition, refer to the specifications for the main breaker<br />

versions of the load center you are considering to review allowed wire ranges when a TLMXX20 load center is<br />

converted to main breaker.<br />

Arc Fault<br />

THQL1115DF<br />

THQL2120GFT<br />

THQMV100D with filler plates<br />

1-6<br />

<strong>BuyLog</strong> <strong>Catalog</strong><br />

www.geindustrial.com Rev. 11/13<br />

Data subject to change<br />

without notice


Load Centers and Circuit Breakers<br />

Special Purpose Circuit Breakers<br />

60°C / 75°F Conductor Rating<br />

Box Type Terminals<br />

Quick-Make, Quick-Break<br />

Multi-pole Breakers Incorporate Internal Common Trip<br />

Section 1<br />

PowerMark Gold Main Circuit Breaker Kit<br />

For use with 125A PowerMark Gold load Centers; 22kAIC RMS symmetrical.<br />

Description<br />

Product Number<br />

Main Circuit Breaker Kit - Order appropriate THQL TQMH000 1<br />

10kAIC or THHQL 22kAIC breakers separately<br />

1 Please review the footnotes listed with the individual Load Center product numbers for proper parts needed to<br />

convert to a main circuit breaker. This main breaker base is only applicable for 16 circuit and larger 125 amp load<br />

centers, 12 circuit load centers with A C24 suffix, and the TLM812RCU2.<br />

Ground Fault with Equipment Protection<br />

cULus<br />

Ground Fault Circuit Interrupters No. 943 30 milliampere ground fault trip level<br />

1-Pole, 120 Volts ac<br />

2-Pole, 120/240 Volts ac<br />

Ampere Rating Product Number Product Number<br />

10,000 AIC<br />

15 THQL1115GFEP THQL2115GFEP<br />

20 THQL1120GFEP THQL2120GFEP<br />

30 THQL1130GFEP THQL2130GFEP<br />

Std. Pkg. 10 Cartons of 1 10 Cartons of 1<br />

Switching Neutral<br />

UL Listed. 10kAIC RMS symmetrical.<br />

Standard 1- or 2-pole automatic breaker plus one fully-rated, non-automatic pole.<br />

1-Pole Plus Switching Neutral<br />

2-Pole Plus Switching Neutral<br />

120/240 Volts ac 120/240 Volts ac<br />

Ampere Rating Product Number Product Number<br />

15 THQL21WY15 THQL31WY15<br />

20 THQL21WY20 THQL31WY20<br />

25 THQL21WY25 THQL31WY25<br />

30 THQL21WY30 THQL31WY30<br />

Std. Pkg. 5 cartons of 5 5 cartons of 3<br />

"HID" Lighting<br />

UL Listed as HID. HID breakers have been designed to handle the current and voltage<br />

spikes that result when gaseous discharge lamps, including fluorescent and HID lamps,<br />

are switched on and off.<br />

10,000 AIC<br />

1-Pole, 120/240 Volts ac<br />

2-Pole, 120/240 Volts ac<br />

Ampere Rating Product Number Product Number<br />

15 THQL1115HID 2 THQL2115HID<br />

20 THQL1120HID 2 THQL2120HID<br />

30 THQL1130HID THQL2130HID<br />

22,000 AIC<br />

15 THHQL1115HID 2 THHQL2115HID<br />

20 THHQL1120HID 2 THHQL2120HID<br />

30 THHQL1130HID THHQL2130HID<br />

Std. Pkg. 5 cartons of 10 5 cartons of 5<br />

2 UL Listed as SWD (switching duty). Suitable for 120 volts ac fluorescent lighting loads.<br />

High Magnetic<br />

UL Listed. 10kAIC RMS symmetrical<br />

High short circuit setting suitable for circuits with inherent high-inrush load currents.<br />

Ampere Rating<br />

1-Pole, 120/240 Volts ac<br />

Product Number<br />

15 THQL1115HM<br />

20 THQL1120HM<br />

25 THQL1125HM<br />

30 THQL1130HM<br />

40 THQL1140HM<br />

50 THQL1150HM<br />

Std. Pkg. 5 cartons of 10<br />

TQMH000<br />

THQL21WY30<br />

THQL2120HID<br />

THQL1140HM<br />

Rev. 11/13<br />

Prices and data subject<br />

to change without notice<br />

www.geindustrial.com <strong>BuyLog</strong> <strong>Catalog</strong> 1-7


Load Centers and Circuit Breakers<br />

Special Purpose Circuit Breakers<br />

60°C / 75°F Conductor Rating<br />

Box Type Terminals<br />

Quick-Make, Quick-Break<br />

Multi-pole Breakers Incorporate Internal Common Trip<br />

Section 1<br />

Molded Case Switches<br />

UL Listed<br />

Without overload or short circuit protection.<br />

120/240 Volts ac<br />

TQ Circuit Breakers<br />

2-Pole<br />

3-Pole<br />

Ampere Rating Product Number Product Number<br />

60 TQL21Y60 –<br />

100 TQL21Y100 –<br />

240 Volts ac<br />

60 TQL22Y60 TQL32Y60<br />

100 TQL22Y100 TQL32Y100<br />

Std. Pkg. 5 cartons of 5 5 cartons of 3<br />

Interlocking Circuit Breakers for use in PowerMark Gold Generator Panels<br />

Two breakers required for interlocking.<br />

Poles Ampere Rating Product Number<br />

2 30 THQL2130GEN<br />

2 60 THQL2160GEN<br />

3/4" UL Classified Circuit Breakers for use in *Square D **QO Load Centers.<br />

10 kAIC RMS symmetrical<br />

1-Pole<br />

2-Pole<br />

Ampere Rating Product Number Product Number<br />

15 TQ1115 TQ2115<br />

20 TQ1120 TQ2120<br />

30 TQ1130 TQ2130<br />

40 TQ1140 TQ2140<br />

50 TQ1150 TQ2150<br />

60 – TQ2160<br />

Std. Pkg. 1 carton of 10 1 carton of 5<br />

THQL 120/240 Vac, with Factory Installed Shunt 1<br />

# of Ampere 120/240 Vac<br />

Poles Rating Wire Range 2 Interrupting Rating Product Number<br />

1 15 (1) 14-8 Cu/12-8 Al 10kA THQL1115ST1<br />

1 20 (1) 14-8 Cu/12-8 Al 10kA THQL1120ST1<br />

1 30 (1) 14-8 Cu/12-8 Al 10kA THQL1130ST1<br />

1 35 (1) 8-3 Cu/8-3 Al 10kA THQL1135ST1<br />

1 40 (1) 8-3 Cu/8-3 Al 10kA THQL1140ST1<br />

1 45 (1) 8-3 Cu/8-3 Al 10kA THQL1145ST1<br />

1 50 (1) 8-3 Cu/8-3 Al 10kA THQL1150ST1<br />

1 Shunt trip requires one additional pole of space.<br />

THQL 120/240 Vac, Internal Common Trip with Factory Installed Shunt 1<br />

# of Ampere 240 Vac<br />

Poles Rating Wire Range 2 Interrupting Rating Product Number<br />

2 15 14-8 Cu/12-8 Al 10kA THQL2115ST1<br />

2 20 14-8 Cu/12-8 Al 10kA THQL2120ST1<br />

2 30 14-8 Cu/12-8 Al 10kA THQL2130ST1<br />

2 35 8-3 Cu/8-3 Al 10kA THQL2135ST1<br />

2 40 8-3 Cu/8-3 Al 10kA THQL2140ST1<br />

2 45 8-3 Cu/8-3 Al 10kA THQL2145ST1<br />

2 50 8-3 Cu/8-3 Al 10kA THQL2150ST1<br />

2 60 8-3 Cu/8-3 Al 10kA THQL2160ST1<br />

2 70 6-1/0 Cu/4-1/0 Al 10kA THQL2170ST1<br />

2 80 6-1/0 Cu/4-1/0 Al 10kA THQL2180ST1<br />

2 90 6-1/0 Cu/4-1/0 Al 10kA THQL2190ST1<br />

2 100 6-1/0 Cu/4-1/0 Al 10kA THQL21100ST1<br />

3 20 14-8 Cu/12-8 Al 10kA THQL32020ST1<br />

3 30 14-8 Cu/12-8 Al 10kA THQL32030ST1<br />

3 40 8-3 Cu/8-3 Al 10kA THQL32040ST1<br />

3 50 8-3 Cu/8-3 Al 10kA THQL32050ST1<br />

3 60 8-3 Cu/8-3 Al 10kA THQL32060ST1<br />

3 70 6-1/0 Cu/4-1/0 Al 10kA THQL32070ST1<br />

3 80 6-1/0 Cu/4-1/0 Al 10kA THQL32080ST1<br />

3 90 6-1/0 Cu/4-1/0 Al 10kA THQL32090ST1<br />

3 100 6-1/0 Cu/4-1/0 Al 10kA THQL32100ST1<br />

2 Solid or stranded for 14-10 AWG.<br />

*Square D is a registered trademark of SNA Holdings, Inc. **QO is a registered trademark of the Square D Company.<br />

TQL21Y100<br />

TQ1120<br />

TQ2120<br />

THQL1130ST1<br />

THQL2120ST1<br />

THQL32020ST1<br />

1-8 <strong>BuyLog</strong> <strong>Catalog</strong> www.geindustrial.com<br />

Rev. 11/13<br />

Data subject to change<br />

without notice


Load Centers and Circuit Breakers<br />

PowerMark Gold and Plus Load Centers<br />

Single-Phase, Three-Wire, 120/240 Vac<br />

Main Lugs Convertible to Main Breaker<br />

Section 1<br />

Load Center<br />

1PH<br />

Main Lug<br />

Indoor NEMA 1<br />

Product Features<br />

—UL Listed (Panelboards No. 67)<br />

—60°/75°C Conductor Rating<br />

—Suitable for Use as Service Entrance Equipment when Installed<br />

in Accordance with the National Electrical Code<br />

—22kAIC RMS symmetrical, Except Where Noted<br />

—6-42 circuit devices UL Listed for bottom mounted lugs by<br />

installing complete unit (box, interior and front) upside down.<br />

—For a listing of CSA Listed load centers, visit geindustrial.com.<br />

TLM2020CCU<br />

TPL412R<br />

Main Lugs Factory Installed (TLM units convertible to main breaker),<br />

Indoor (NEMA 1) Enclosure<br />

Main 1 Pole, 2 Pole, 1 Pole, 2 Pole, Total Main Wire Size<br />

Ampere 1” 1” 1/2” 1/2” 1-pole Front Box (AWG/kcmil) Equipment Product<br />

Rating Spaces Spaces Spaces Spaces Spaces Type Feed Type 1 Number Cu-Al Ground Kit Number<br />

40 2 1 4 1 4 Surface Top 1A 14-4 TGK4 (order separately) TL240SCU 1,8<br />

Bottom<br />

70 2 1 4 1 4 Surface Top 1A 6-3 TGK4 (order separately) TL270SCU 1,8<br />

Bottom<br />

125 4 2 8 3 8 Combination Top 2A 1-2/0 TGL1 (order separately) TL412C 1,2,8<br />

Flush/Surface Bottom<br />

125 4 2 8 3 8 Combination Top 2A 1-2/0 TGL1 installed TL412CT 1,2,3,8<br />

Flush/Surface Bottom<br />

125 4 2 8 3 8 Thermoplastic Top 2 1-2/0 TGL1 (order separately) TPL412C 1,2,3,8<br />

Bottom<br />

125 4 2 8 3 8 Thermoplastic Top 2 1-2/0 TGL1 installed TPL412CT 1,2,3,8<br />

Bottom<br />

125 6 3 12 4 12 Flush Top 3A 6-1 TGL2 (order separately) TLM612FCU 4,8<br />

Bottom<br />

125 6 3 12 4 12 Flush Top 3A 6-1 TGL2 (order separately) TLM612FCUD 4,8<br />

Bottom<br />

125 6 3 12 4 12 Flush Top 3A 6-1 TGL2 installed TLM612FCUDG 4,8<br />

Bottom<br />

125 6 3 12 4 12 Surface Top 3A 6-1 TGL2 (order separately) TLM612SCU 4,8<br />

Bottom<br />

125 6 3 12 4 12 Surface Top 3A 6-1 TGL2 (order separately) TLM612SCUD 4,8<br />

Bottom<br />

125 6 3 12 4 12 Surface Top 3A 6-1 TGL2 installed TLM612SCUDG 4,8<br />

Bottom<br />

125 8 4 16 8 16 Flush Top 3A 6-1 TGL2 (order separately) TLM812FCU 4,8<br />

Bottom<br />

125 8 4 16 8 16 Flush Top 3A 6-1 TGL2 (order separately) TLM812FCUD 4,8<br />

Bottom<br />

125 8 4 16 8 16 Flush Top 3A 6-1 TGL2 (order separately) TLM812FCUDG 4,8<br />

Bottom<br />

125 8 4 16 8 16 Surface Top 3A 6-1 TGL2 (order separately) TLM812SCU 4,8<br />

Bottom<br />

125 8 4 16 8 16 Surface Top 3A 6-1 TGL2 (order separately) TLM812SCUD 4,8<br />

Bottom<br />

125 8 4 16 8 16 Surface Top 3A 6-1 TGL2 installed TLM812SCUDG 4,8<br />

Bottom<br />

125 14 6 20 8 24 Combination Top 18 6-2/0 Included 10 TLM1212CCU 7,8<br />

Flush/Surface Bottom<br />

125 14 6 20 8 24 White Combo Top 18 6-2/0 Included 10 TLM1212CCUW 7,8,9<br />

Flush/Surface Bottom<br />

This table continued on next page<br />

Rev. 11/13<br />

Data subject to change<br />

without notice<br />

www.geindustrial.com<br />

<strong>BuyLog</strong> <strong>Catalog</strong><br />

1-9


Load Centers and Circuit Breakers<br />

PowerMark Gold and Plus Load Centers<br />

Single-Phase, Three-Wire, 120/240 Vac<br />

Main Lugs Convertible to Main Breaker<br />

Section 1<br />

Load Center<br />

1PH<br />

Main Lug<br />

Indoor NEMA 1<br />

Main Lugs Factory Installed (TLM units convertible to main breaker),<br />

Indoor (NEMA 1) Enclosure<br />

Main 1 Pole, 2 Pole, 1 Pole, 2 Pole, Total Main Wire Size<br />

Ampere 1” 1” 1/2” 1/2” 1-pole Front Box (AWG/kcmil) Equipment Product<br />

Rating Spaces Spaces Spaces Spaces Spaces Type Feed Type Number Cu-Al Ground Kit Number<br />

125 16 8 16 6 24 Combination Top 4 6-2/0 TGK12 and TGK24 TLM1612CCU 5<br />

Flush/Surface Bottom (order separately)<br />

125 16 8 16 6 24 Combination Top 4 6-2/0 TGK12 and TLK20 TLM1612CCUG 7<br />

Flush/Surface Bottom installed<br />

125 24 12 0 0 24 Combination Top 7 6-2/0 TGK24 and TGK32 TLM2412CCU 5<br />

Flush/Surface Bottom (order separately)<br />

125 24 12 0 0 24 White Combo Top 7 6-2/0 TGK24 and TGK32 TLM2412CCUW 5,9<br />

Flush/Surface Bottom (order separately)<br />

125 24 12 0 0 24 Combination Top 7 6-2/0 TGK24 and TLK20 TLM2412CCUG 7<br />

Flush/Surface Bottom installed<br />

200 16 8 32 14 32 Combination Top 7 6-250 TGK32 TLM1620CCU 6<br />

Flush/Surface Bottom (order separately)<br />

200 16 8 32 14 32 White Combo Top 7 6-250 TGK32 TLM1620CCUW 6,9<br />

Flush/Surface Bottom (order separately)<br />

200 16 8 32 14 32 Combination Top 7 6-250 TGK32 TLM1620CCUG 6<br />

Flush/Surface Bottom installed<br />

200 20 10 40 18 40 Combination Top 8 6-250 TGK32 TLM2020CCU 6<br />

Flush/Surface Bottom (order separately)<br />

200 20 10 40 18 40 White Combo Top 8 6-250 TGK32 TLM2020CCUW 6,9<br />

Flush/Surface Bottom (order separately)<br />

200 20 10 40 18 40 Combination Top 8 6-250 TGK42 TLM2020CCUG 6<br />

Flush/Surface Bottom installed<br />

200 24 12 36 18 42 Combination Top 9 1-3/0 (Cu), TGK24 and TLK32 TLM2420C42 6<br />

Flush/Surface Bottom 2/0-3/0 (Al) (order separately)<br />

200 32 16 20 8 42 Combination Top 11 1-250 (Cu), TGK32 and TLK20 TLM3220C42 6<br />

Flush/Surface Bottom 2/0-250 (Al) (order separately)<br />

200 32 16 16 6 40 Combination Top 11 6-250 TGK32 TLM3220CCU 6<br />

Flush/Surface Bottom (order separately)<br />

200 32 16 16 6 40 White Combo Top 11 6-250 TGK32 TLM3220CCUW 6,9<br />

Flush/Surface Bottom (order separately)<br />

200 40 20 0 0 40 Combination Top 13 6-250 TGK42 TLM4020CCU 6<br />

Flush/Surface Bottom (order separately)<br />

200 40 20 0 0 40 White Combo Top 13 6-250 TGK42 TLM4020CCUW 6,9<br />

Flush/Surface Bottom (order separately)<br />

200 42 20 0 0 42 Combination Top 14 1-300 (Cu), TGK42 TLM4220CCU 6<br />

Flush/Surface Bottom 2/0-300 (Al) (order separately)<br />

225 42 20 0 0 42 Combination Top 14 1-300 (Cu), TGK42 TLM4222CCU 6<br />

Flush/Surface Bottom 2/0-300 (Al) (order separately)<br />

1 No door<br />

10 kAIC<br />

3 125 amp maximum branch capacity.<br />

4 For main breaker, order THQLRK2 retainer kit plus 2-pole circuit breaker. See page 1-28, 100 amp max.<br />

5 For main breaker, order TQMH000. See page 1-24. Also order 2-pole THQL, THHQL, or TXQL circuit breaker. See page 1-5.<br />

6 For main breaker, order THQMVXXXD circuit breaker from page 1-6.<br />

7 For main breaker applications, use reverse feed THQL breaker or THHQL circuit breaker (see page 1-5) and THQLRK3 breaker retainer (see page 1-28).<br />

8 No lock provision available. Use next size larger load center such as TLM1612CCU with a TDL106 accessory if locking provision is required.<br />

9 Minimum order QTY is 40 for below 24 circuits; QTY 24 for 24 circuits and above. (See DEE-590)<br />

10 Load center includes a factory installed ground bar and add-a-lug. See wiring diagram on page 1-30. A separate TGL2 can be added in the unlikey event<br />

that another ground bar is required.<br />

Note: See page 11-4, AL Series Lighting Panelboards as replacements for 300-600A load centers.<br />

1-10 <strong>BuyLog</strong> <strong>Catalog</strong> www.geindustrial.com<br />

Rev. 11/13<br />

Data subject to change<br />

without notice


Load Centers and Circuit Breakers<br />

PowerMark Gold and Plus Load Centers<br />

Single-Phase, Three-Wire, 120/240 Vac<br />

Main Lugs Convertible to Main Breaker<br />

Section 1<br />

Load Center<br />

1PH<br />

Main Lug<br />

Outdoor NEMA 3R<br />

Main Lugs Factory Installed (TLM units convertible to main breaker),<br />

Outdoor (NEMA 3R) Enclosure 1<br />

Main 1 Pole, 2 Pole, 1 Pole, 2 Pole, Total Main Wire Size<br />

Ampere 1” 1” 1/2” 1/2” 1-pole Front Feed 1 Box (AWG/kcmil) Equipment Product<br />

Rating Spaces Spaces Spaces Spaces Spaces Type Type Number Cu-Al Ground Kit Number<br />

40 2 1 4 1 4 Top R1A 14-4 TGK4 (order separately) TL240RCU<br />

70 2 1 4 1 4 Top R1A 6-3 TGK4 (order separately) TL270RCU<br />

100 5 0 0 0 5 Flush Top R41 6-3 TGL1 installed TL510RT 2,8<br />

125 4 2 8 3 8 Top R1A 1-2/0 TGL1 (order separately) TL412R1 2<br />

125 4 2 8 3 8 Top R1A 1-2/0 TGL1 installed TL412RT1 2<br />

125 4 2 8 3 8 Top R41 1-2/0 TGL1 (order separately) TL412R2 2<br />

125 4 2 8 3 8 Thermoplastic Top R1 1-2/0 TGL1 (order separately) TPL412R 2,3<br />

Front<br />

125 4 2 8 3 8 Thermoplastic Top R1 1-2/0 TGL1 installed TPL412RT 2,3<br />

Front<br />

125 4 3 12 4 12 Top R2A 6-1 TGK12 (order separately) TLM612RCU 4<br />

125 8 4 16 8 16 Top R2A 6-1 TGK12 (order separately) TLM812RCU 4<br />

125 8 4 16 8 16 Top R3A 6-1 TGK12 (order separately) TLM812RCU2 5<br />

125 14 6 20 8 24 Top R3A 6-2/0 Included TLM1212RCU 7,9<br />

125 24 12 0 0 24 Top R4A 6-2/0 TGK24 (order separately) TLM2412RCU 5<br />

Bottom<br />

TGK32 (order separately)<br />

150 24 12 12 4 30 Top R6A 1-3/0 (Cu), TGK24 (order separately) TLM2415RCU 6<br />

Bottom 2/0-3/0 (Al) TGK32 (order separately)<br />

200 12 6 24 10 24 Top R5A 6-250 TGK24 (order separately) TLM1220RCU 6<br />

200 16 8 32 14 32 Top R5A 6-250 TGK32 (order separately) TLM1620RCU 6<br />

200 20 10 40 18 40 Top R6A 6-250 TGK24 (order separately) TLM2020RCU 6<br />

TGK42 (order separately)<br />

200 24 12 36 18 42 Top R39 1-250 (Cu), TGK24 (order separately) TLM2420R42<br />

Bottom<br />

2/0-250 (Al)<br />

200 32 16 16 6 40 Top R7A 1-250 (Cu), 2/0-250 (Al) TGK32 (order separately) TLM3220RCU 6<br />

Bottom<br />

200 40 20 0 0 40 Top R8A 6-250 TGK42 (order separately) TLM4020RCU 6<br />

Bottom<br />

225 42 20 0 0 42 Top R8A 1-300 (Cu), TGK42 (order separately) TLM4222RCU 6<br />

Bottom<br />

2/0-300 (Al)<br />

1 40-225 amp single-phase devices have removable closing caps. Larger ampere devices require field-cut openings. Order hubs separately. See page 1-27.<br />

2 10 kAIC.<br />

3 125 amp maximum branch capacity.<br />

4 For main breaker, order THQLRK2 retainer kit plus 2-pole circuit breaker. See page 1-28, 100 amp maximum due to wire bending requirements.<br />

5 For main breaker, order TQMH000. See page 1-24. Also order 2-pole THQL or THHQL circuit breaker. See page 1-5.<br />

6 For main breaker, order THQMVXXXD circuit breaker from page 1-6.<br />

7 For main breaker applications, use reverse feed THQL or THHQL circuit breaker (see page 1-5) and THQLRK3 breaker retainer (see page 1-28).<br />

8 Main and branch breakers are limited to 70 amps.<br />

9 Load center includes a factory installed ground bar and add-a-lug. See wiring diagram on page 1-30. A separate TGL2 can be added in the unlikey event<br />

that another ground bar is required.<br />

Note: See page 11-4, AL Series Lighting Panelboards as replacements for 300-600A load centers.<br />

Rev. 11/13<br />

Data subject to change<br />

without notice<br />

www.geindustrial.com<br />

<strong>BuyLog</strong> <strong>Catalog</strong><br />

1-11


Load Centers and Circuit Breakers<br />

PowerMark Gold and Plus Main Breaker Load Centers<br />

Single-Phase, Three-Wire, 120/240 Vac<br />

Main Breaker Factory Installed<br />

Section 1<br />

Load Center<br />

1PH<br />

Main Breaker<br />

Indoor NEMA 1<br />

Product Features<br />

—UL Listed (Panelboards No. 67)<br />

—60°C/75°C Conductor Rating<br />

—Suitable for Use as Service Entrance Equipment when Installed<br />

in Accordance with the National Electrical Code<br />

—22kAIC RMS symmetrical, Except Where Noted<br />

—6-42 circuit devices UL Listed for bottom mounted lugs by<br />

installing complete unit (box, interior and front) upside down.<br />

—For a listing of CSA Listed load centers, visit geindustrial.com.<br />

TM2020CCU<br />

TM820RCUFL<br />

Indoor (NEMA 1) Enclosure<br />

Main 1 Pole, 2 Pole, 1 Pole, 2 Pole, Total Main Wire Size<br />

Ampere 1” 1” 1/2” 1/2” 1-pole Front Feed Box (AWG/kcmil) Equipment Product<br />

Rating Spaces Spaces Spaces Spaces Spaces Type Type Number Cu-Al Ground Kit Number<br />

100 12 5 20 8 22 Combination Top 18 4-1/0 Included 1 TM1210CCU 2<br />

Flush/Surface Bottom<br />

Front<br />

100 24 12 0 0 24 Combination Top 7 1-2/0 TGK24, TGK32 and TM2410CCU<br />

Flush/Surface Bottom TLK20 (order separately)<br />

Front<br />

100 20 10 0 0 20 Combination Top 6 4-1/0 TGK24 (order separately) TM2010CCU<br />

Flush/Surface Bottom<br />

Front<br />

100 32 16 0 0 32 Combination Top 11 4-1/0 TGK32 (order separately) TM3210CCU<br />

Flush/Surface Bottom<br />

Front<br />

125 12 5 20 8 22 Combination Top 18 1-2/0 Included 1 TM1212CCU 2<br />

Flush/Surface Bottom<br />

Front<br />

125 24 12 0 0 24 Combination Top 7 1-2/0 TGK24 (order separately) TM2412CCU<br />

Flush/Surface Bottom<br />

Front<br />

125 16 8 16 6 24 Combination Top 4 1-2/0 TGK12 (order separately) TM1612CCU<br />

Flush/Surface Bottom TGK24 (order separately)<br />

Front<br />

125 16 8 16 6 24 Combination Top 4 1-2/0 TGK24 installed TM1612CCUG<br />

Flush/Surface Bottom<br />

Front<br />

150 16 8 32 14 32 Combination Top 7 1-3/0 (Cu), TGK24 (order separately) TM1615CCU<br />

Flush/Surface Bottom 2/0-3/0 (Al) TGK32 (order separately)<br />

Front<br />

150 16 8 32 14 32 Combination Top 7 1-3/0 (Cu), TGK32 installed TM1615CCUG<br />

Flush/Surface Bottom 2/0-3/0 (Al)<br />

Front<br />

This table continued on next page<br />

1-12 <strong>BuyLog</strong> <strong>Catalog</strong> www.geindustrial.com<br />

Rev. 11/13<br />

Data subject to change<br />

without notice


Load Centers and Circuit Breakers<br />

PowerMark Gold and Plus Main Breaker Load Centers<br />

Single-Phase, Three-Wire, 120/240 Vac<br />

Main Breaker Factory Installed<br />

Section 1<br />

Load Center<br />

1PH<br />

Main Breaker<br />

Indoor NEMA 1<br />

Indoor (NEMA 1) Enclosure<br />

Main 1 Pole, 2 Pole, 1 Pole, 2 Pole, Total Main Wire Size<br />

Ampere 1” 1” 1/2” 1/2” 1-pole Front Feed Box (AWG/kcmil) Equipment Product<br />

Rating Spaces Spaces Spaces Spaces Spaces Type Type Number Cu-Al Ground Kit Number<br />

150 32 16 0 0 32 Combination Top 11 1-3/0 (Cu), TGK32 (order separately) TM3215CCU<br />

Flush/Surface Bottom 2/0-3/0 (Al)<br />

150 24 12 36 18 42 Combination Top 9 1-3/0 (Cu), TGK24 (order separately) TM2415C42<br />

Flush/Surface Bottom 2/0-3/0 (Al) TLK32 (order separately)<br />

150 32 16 20 10 42 Combination Top 11 1-3/0 (Cu), TGK32 and TLK20 TM3215C42<br />

Flush/Surface Bottom 2/0-3/0 (Al) (order separately)<br />

200 16 8 32 14 32 Combination Top 7 1-250 (Cu), TGK32 (order separately) TM1620CCU<br />

Flush/Surface Bottom 2/0-250 (Al)<br />

200 16 8 32 14 32 Combination Top 8 1-250 (Cu), TGK32 installed TM1620CCUG<br />

Flush/Surface Bottom 2/0-250 (Al)<br />

200 20 10 40 18 40 Combination Top 8 1-250 (Cu), TGK32 (order separately) TM2020CCU<br />

Flush/Surface Bottom 2/0-250 (Al)<br />

200 20 10 40 18 40 White Combo Top 8 1-250 (Cu), TGK24 (order separately) TM2020CCUW 3<br />

Flush/Surface Bottom 2/0-250 (Al) TGK42 (order separately)<br />

200 20 10 40 18 40 Combination Top 8 1-250 (Cu), TGK32 (order separately) TM2020CCUG<br />

Flush/Surface Bottom 2/0-250 (Al)<br />

200 20 10 40 18 40 White Combo Top 8 1-250 (Cu), TGK32 (order separately) TM2020CCUGW 3<br />

Flush/Surface Bottom 2/0-250 (Al)<br />

200 32 16 16 6 40 Combination Top 11 1-250 (Cu), TGK32 (order separately) TM3220CCU<br />

Flush/Surface Bottom 2/0-250 (Al)<br />

200 40 20 0 0 40 Combination Top 13 1-250 (Cu), TGK42 (order separately) TM4020CCU<br />

Flush/Surface Bottom 2/0-250 (Al)<br />

200 32 16 20 8 42 Combination Top 11 1-250 (Cu), TGK32 and TLK20 TM3220C42<br />

Flush/Surface Bottom 2/0-250 (Al) (order separately)<br />

200 42 20 0 0 42 Combination Top 14 1-300 (Cu), TGK42 (order separately) TM4220CCU<br />

Flush/Surface Bottom 2/0-300 (Al)<br />

225 42 20 0 0 42 Combination Top 14 1-300 (Cu), TGK42 (order separately) TM4222CCU<br />

Flush/Surface Bottom 2/0-300 (Al)<br />

1 Load center includes a factory installed ground bar and add-a-lug. See wiring diagram on page 1-30. A separate TGL2 can be added in the unlikey event<br />

that another ground bar is required.<br />

2 No lock provision available. Use next size larger load center such as TLM1612CCU with a TDL106 accessory if locking provision is required.<br />

3 Minimum order QTY is 40 for below 24 circuits; QTY 24 for 24 circuits and above. (See DEE-590)<br />

Outdoor (NEMA 3R) Enclosure 4<br />

Load Center<br />

1PH<br />

Main Breaker<br />

Outdoor NEMA 3R<br />

Main 1 Pole, 2 Pole, 1 Pole, 2 Pole, Total Main Wire Size<br />

Ampere 1” 1” 1/2” 1/2” 1-pole Feed Box (AWG/kcmil) Equipment Product<br />

Rating Spaces Spaces Spaces Spaces Spaces Type Number Cu-Al Ground Kit Number<br />

100 12 5 20 8 22 Top R3A 4-1/0 TGK12 (order separately) TM1210RCU<br />

TGK24 (order separately)<br />

100 20 10 0 0 30 Top R4 4-1/0 TGK24 (order separately) TM2010RCU<br />

125 12 5 20 8 22 Top R3A 1-2/0 TGK12 (order separately) TM1212RCU<br />

TGK24 (order separately)<br />

125 24 12 0 0 24 Top R4 1-2/0 TGK24 (order separately) TM2412RCU<br />

150 8 4 16 6 16 Top R5 1-250 (Cu), 2/0-250 (Al) TGK24 (order separately) TM815RCUFL<br />

150 16 8 32 14 32 Top R5 1-3/0 (Cu), 2/0-3/0 (Al) TGK24 (order separately) TM1615RCU<br />

TGK32 (order separately)<br />

150 24 12 12 4 30 Top R6 1-3/0 (Cu), 2/0-3/0 (Al) TGK24 (order separately) TM2415RCU<br />

TGK32 (order separately)<br />

150 24 12 36 18 42 Top R39 1-250 (Cu), 2/0-250 (Al) TGK24 (order separately) TM2415R42<br />

Bottom<br />

150 32 16 0 0 32 Top R7 1-3/0 (Cu), 2/0-3/0 (Al) TGK32 (order separately) TM3215RCU<br />

200 8 4 16 6 16 Top R5 1-250 (Cu), 2/0-250 (Al) TGK32 (order separately) TM820RCUFL<br />

200 20 10 40 18 40 Top R6 1-250 (Cu), 2/0-250 (Al) TGK24 (order separately) TM2020RCU<br />

TGK42 (order separately)<br />

200 24 12 36 18 42 Top R39 1-250 (Cu), 2/0-250 (Al) TGK24 (order separately) TM2420R42<br />

Bottom<br />

200 32 16 16 6 40 Top R7 1-250 (Cu), 2/0-250 (Al) TGK32 (order separately) TM3220RCU<br />

200 40 20 0 0 40 Top R8 1-250 (Cu), 2/0-250 (Al) TGK42 (order separately) TM4020RCU<br />

225 8 4 16 6 16 Top R5 1-250 (Cu), 2/0-250 (Al) TGK24 (order separately) TM822RCUFL<br />

225 42 20 0 0 42 Top R8 1-300 (Cu), 2/0-300 (Al) TGK42 (order separately) TM4222RCU<br />

4 100-225 amp devices have removable closing caps. Larger ampere devices require field-cut openings. Order hubs separately. See page 1-27.<br />

Note: See page 11-4, AL Series Lighting Panelboards as replacements for 300-600A load centers.<br />

Rev. 11/13<br />

Data subject to change<br />

without notice<br />

www.geindustrial.com<br />

<strong>BuyLog</strong> <strong>Catalog</strong><br />

1-13


Load Centers and Circuit Breakers<br />

PowerMark Plus Load Centers<br />

Three-Phase, Four-Wire, 208Y/120 Vac 2<br />

Main Lugs Factory Installed<br />

Section 1<br />

Load Center<br />

3PH<br />

Main Lugs<br />

Indoor NEMA 1<br />

Product Features<br />

—UL Listed (Panelboards No. 67)<br />

—60°/75°C Conductor Rating<br />

—Suitable for Use as Service Entrance Equipment when Installed<br />

in Accordance with the National Electrical Code<br />

—22kAIC RMS symmetrical Short-circuit Rating Standard<br />

—Bottom feed models available where noted with a “B” suffix.<br />

—For a listing of CSA Listed load centers, visit geindustrial.com.<br />

—Copper breaker mounting stabs with aluminum bus 1<br />

Indoor (NEMA 1) Enclosure<br />

Main 1 Pole, 2 Pole, 3 Pole, Total Main Wire Size<br />

Ampere 1” 1” 1” 1-pole Feed Box (AWG/kcmil) Equipment Product<br />

Rating Spaces Spaces Spaces Spaces Front Type Type Number Cu-Al Ground Kit Number<br />

125 12 6 4 12 Combination Top 4 6-2/0 TGK12 (order separately) TL12412C 3<br />

Flush/Surface Bottom TGK24 (order separately)<br />

Front<br />

150 18 8 6 18 Combination Top 7 1-3/0 (Cu), TGK24 (order separately) TL18415C 3<br />

Flush/Surface Bottom 2/0-3/0 (Al) TGK32 (order separately)<br />

Front<br />

150 24 12 8 24 Combination Top 7 1-3/0 (Cu), TGK24 (order separately) TL24415C 3<br />

Flush/Surface Bottom 2/0-3/0 (Al) TGK32 (order separately)<br />

Front<br />

200 18 8 6 18 Combination Top 8 1-250 (Cu), TGK32 (order separately) TL18420C 3<br />

Flush/Surface Bottom 2/0-250 (Al)<br />

Front<br />

200 30 14 10 30 Combination Top 11 1-250 (Cu), TGK32 (order separately) TL30420C 3<br />

Flush/Surface Bottom 2/0-250 (Al)<br />

Front<br />

200 42 20 14 42 Combination Top 13 1-250 (Cu), TGK42 (order separately) TL42420C<br />

Flush/Surface Bottom 2/0-250 (Al)<br />

Front<br />

225 30 14 10 30 Combination Top 15 1-300 (Cu), (2) TGL2 (order separately) TL30422C 4<br />

Flush/Surface Bottom 2/0-300 (Al)<br />

Front<br />

225 42 20 14 42 Combination Top 15 1-300 (Cu), (2) TGL2 (order separately) TL42422C 4<br />

Flush/Surface Bottom 2/0-300 (Al)<br />

Front<br />

1 Three-phase PowerMark Plus load centers have aluminum bus with copper breaker mounting stabs, providing copper-to-copper contact at breaker stabs.<br />

2 Also UL Listed for three-phase, four-wire 240/120 Volts ac delta and three-phase, three-wire 240 Volts ac branch breakers installed.<br />

3 Alternate main breaker: 100 Amp max. THQL (10kAIC), THHQL (22kAIC) three-pole, use retainer THQLRK. See page 1-28.<br />

4 Not suitable for use as service entrance equipment.<br />

Note: See page 11-4, AL Series Lighting Panelboards as replacements for 300-600A load centers.<br />

1-14 <strong>BuyLog</strong> <strong>Catalog</strong> www.geindustrial.com<br />

Rev. 11/13<br />

Data subject to change<br />

without notice


Load Centers and Circuit Breakers<br />

PowerMark Plus Load Centers<br />

Three-Phase, Four-Wire, 208Y/120Vac<br />

Main Circuit Breaker or Main Lugs Factory Installed<br />

Section 1<br />

Load Center<br />

3PH<br />

Main Lugs<br />

Outdoor NEMA 3R<br />

Main Lugs Factory Installed 1<br />

Outdoor (NEMA 3R) Enclosure<br />

Main 1 Pole, 2 Pole, 3 Pole, Total Main Wire Size<br />

Ampere 1” 1” 1” 1-pole Feed Box (AWG/kcmil) Equipment Product<br />

Rating Spaces Spaces Spaces Spaces Type Number Cu-Al Ground Kit Number<br />

125 12 6 4 12 Top R3 6-2/0 TGK12 (order separately) TL12412R 2<br />

TGK24 (order separately)<br />

150 18 8 6 18 Top R4 1-3/0 (Cu), TGK24 (order separately) TL18415R 2<br />

2/0-3/0 (Al) TGK32 (order separately)<br />

150 24 12 8 24 Top R4 1-3/0 (Cu), TGK24 (order separately) TL24415R 2<br />

2/0-3/0 (Al) TGK32 (order separately)<br />

200 18 8 6 18 Top R4 1-250 (Cu), TGK32 (order separately) TL18420R 2<br />

2/0-250 (Al)<br />

200 30 14 10 30 Top R6 1-250 (Cu), TGK32 (order separately) TL30420R 2<br />

2/0-250 (Al)<br />

200 42 20 14 42 Top R8 1-250 (Cu), TGK42 (order separately) TL42420R 3<br />

2/0-250 (Al)<br />

225 42 20 14 42 Top R8 1-300 (Cu), TGK42 (order separately) TL42422R 3<br />

2/0-300 (Al)<br />

1 Also UL Listed for three-phase, four-wire 240/120 Volts ac delta and three-phase, three-wire 240 Volts ac branch breakers installed.<br />

2 Alternate main breaker 100 Amp max. THQL (10kAIC), THHQL (22kAIC) three-pole, use retainer THQLRK. See page 1-28.<br />

3 Not suitable for use as service entrance equipment.<br />

Main Breaker Factory Installed 4<br />

Indoor (NEMA 1) Enclosure<br />

TM24420CB<br />

Main 1 Pole, 2 Pole, 3 Pole, Total Main Wire Size<br />

Ampere 1” 1” 1” 1-pole Feed Box (AWG/kcmil) Equipment Product<br />

Rating Spaces Spaces Spaces Spaces Front Type Type Number Cu-Al Ground Kit Number<br />

100 12 6 4 12 Combination Top 6 6-1/0 (Cu), TGK12 (order separately) TM12410C 5<br />

Flush/Surface Bottom 4-1/0 (Al) TGK24 (order separately)<br />

Front<br />

100 18 8 6 18 Combination Top 6 6-1/0 (Cu), TGK24 (order separately) TM18410C 5<br />

Flush/Surface Bottom 4-1/0 (Al) TGK32 (order separately)<br />

Front<br />

125 30 14 10 30 Combination Top 11 1-3/0 (Cu), TGK32 (order separately) TM30412C<br />

Flush/Surface<br />

2/0-3/0 (Al)<br />

Front<br />

125 30 14 10 30 Combination Bottom 11 1-3/0 (Cu), TGK32 (order separately) TM30412CB<br />

Flush/Surface<br />

2/0-3/0 (Al)<br />

Front<br />

150 24 12 8 24 Combination Top 11 1-3/0 (Cu), TGL1, TGL2, TGL20,TNG3, TM24415C<br />

Flush/Surface 2/0-3/0 (Al TGN6 (order separately)<br />

Front<br />

150 24 12 8 24 Combination Bottom 11 1-3/0 (Cu), TGK32 (order separately) TM24415CB<br />

Flush/Surface<br />

2/0-3/0 (Al)<br />

Front<br />

150 30 14 10 30 Combination Top 11 1-3/0 (Cu), TGK32 (order separately) TM30415C<br />

Flush/Surface<br />

2/0-3/0 (Al)<br />

Front<br />

150 30 14 10 30 Combination Bottom 11 1-3/0 (Cu), TGK32 (order separately) TM30415CB<br />

Flush/Surface<br />

2/0-3/0 (Al)<br />

Front<br />

150 42 20 14 42 Combination Top 13 1-3/0 (Cu), TGK42 (order separately) TM42415C<br />

Flush/Surface<br />

2/0-3/0 (Al)<br />

Front<br />

150 42 20 14 42 Combination Bottom 13 1-3/0 (Cu), TGK42 (order separately) TM42415CB<br />

Flush/Surface<br />

2/0-3/0 (Al)<br />

Front<br />

200 24 12 8 24 Combination Top 11 1-300 (Cu), TGK32 (order separately) TM24420C<br />

Flush/Surface<br />

2/0-300 (Al)<br />

Front<br />

200 24 12 8 24 Combination Bottom 11 1-300 (Cu), TGK32 (order separately) TM24420CB<br />

Flush/Surface<br />

2/0-300 (Al)<br />

Front<br />

4 Also UL Listed for three-phase, four-wire 240/120 Volts Hi leg delta and three-phase, three-wire 240 Volts ac branch breakers installed.<br />

5 100 Amp indoor devices UL listed for bottom-feed by installing complete unit upside-down.<br />

Load Center<br />

3PH<br />

Main Breaker<br />

Indoor NEMA 1<br />

Note: See page 11-4, AL Series Lighting Panelboards as replacements for 300-600A load centers.<br />

This table continued on next page<br />

Rev. 11/13<br />

Data subject to change<br />

without notice<br />

www.geindustrial.com<br />

<strong>BuyLog</strong> <strong>Catalog</strong><br />

1-15


Load Centers and Circuit Breakers<br />

PowerMark Plus Load Centers<br />

Three-Phase, Four-Wire, 208Y/120 Vac 1<br />

Main Circuit Breaker Factory Installed<br />

Section 1<br />

Load Center<br />

3PH<br />

Main Breaker<br />

Indoor NEMA 1<br />

Indoor (NEMA 1) Enclosure<br />

Main 1 Pole, 2 Pole, 3 Pole, Total Main Wire Size<br />

Ampere 1” 1” 1” 1-pole Feed Box (AWG/kcmil) Equipment Product<br />

Rating Spaces Spaces Spaces Spaces Front Type Type Number Cu-Al Ground Kit Number<br />

200 30 14 10 30 Combination Top 12 1-250 (Cu), TGK32 (order separately) TM30420C<br />

Flush/Surface<br />

2/0-250 (Al)<br />

Front<br />

200 30 14 10 30 Combination Bottom 12 1-250 (Cu), TGK32 (order separately) TM30420CB<br />

Flush/Surface<br />

2/0-250 (Al)<br />

Front<br />

200 42 20 14 42 Combination Top 14 1-250 (Cu), TGK42 (order separately) TM42420C<br />

Flush/Surface<br />

2/0-250 (Al)<br />

Front<br />

200 42 20 14 42 Combination Bottom 14 1-250 (Cu), TGK42 (order separately) TM42420CB<br />

Flush/Surface<br />

2/0-250 (Al)<br />

Front<br />

225 42 20 14 42 Combination Top 15 1-300 (Cu), (2) TGL2 (order separately) TM42422C<br />

Flush/Surface<br />

2/0-300 (Al)<br />

Front<br />

225 42 20 14 42 Combination Bottom 15 1-300 (Cu), (2) TGL2 (order separately) TM42422CB<br />

Flush/Surface<br />

2/0-300 (Al)<br />

Front<br />

1 Also UL Listed for three-phase, four-wire 240/120 Volts Hi leg delta and three-phase, three-wire 240 Volts ac branch breakers installed.<br />

Outdoor (NEMA 3R) Enclosure<br />

Load Center<br />

3PH<br />

Main Breaker<br />

Outdoor NEMA 3R<br />

Main 1 Pole, 2 Pole, 3 Pole, Total Main Wire Size<br />

Ampere 1” 1” 1” 1-pole Feed Box (AWG/kcmil) Equipment Product<br />

Rating Spaces Spaces Spaces Spaces Type Number Cu-Al Ground Kit Number<br />

100 18 8 6 18 Top R4 6-1/0 (Cu), TGK24 (order separately) TM18410R<br />

4-1/0 (Al) TGK32 (order separately)<br />

125 30 14 10 30 Top R7 1-3/0 (Cu), TGK32 (order separately) TM30412R<br />

2/0-3/0 (Al)<br />

150 24 12 8 24 Top R6 1-3/0 (Cu), TGK32 (order separately) TM24415R<br />

2/0-3/0 (Al)<br />

150 30 14 10 30 Top R7 1-3/0 (Cu), TGK32 (order separately) TM30415R<br />

2/0-3/0 (Al)<br />

200 30 14 10 30 Top R7 1-250 (Cu), TGK32 (order separately) TM30420R<br />

2/0-250 (Al)<br />

200 42 20 14 42 Top R8 1-250 (Cu), TGK42 (order separately) TM42420R<br />

2/0-250 (Al)<br />

225 42 20 14 42 Top R8 1-300 (Cu), TGK42 (order separately) TM42422R<br />

2/0-300 (Al)<br />

Note: See page 11-4, AL Series Lighting Panelboards as replacements for 300-600A load centers.<br />

1-16 <strong>BuyLog</strong> <strong>Catalog</strong> www.geindustrial.com<br />

Rev. 11/13<br />

Data subject to change<br />

without notice


Load Centers and Circuit Breakers<br />

PowerMark Gold Load Centers<br />

Single-Phase, Three-Wire, 120/240 Vac<br />

Section 1<br />

Load Center<br />

Generator Panels<br />

Riser Panels<br />

Spa Panels<br />

Product Features - Generator Panels<br />

—Suitable for use in accordance with Article 702 of the National<br />

Electrical Code, ANSI/NFPA 70<br />

—Single-phase, 2 interlock 60A or 30A main breakers, 8 circuits<br />

max.<br />

—Safety and convenience when using a generator - 14,000 peak<br />

wattage, 11,520 continuous load, 48 amps at 240 volts.<br />

—Maintains power to such critical circuits as those for furnace,<br />

pump, refrigerator, lights.<br />

—Connected dual breaker mechanism ensures that only one<br />

source is active at a time.<br />

TL412R250GF<br />

TM830FCUGEN<br />

Generator Panels, Two Interlocked Main Breakers Factory Installed<br />

Indoor (NEMA 1) Enclosure<br />

Main 1 Pole, 2 Pole, 1 Pole, 2 Pole, Total Main Wire Size<br />

Ampere 1” 1” 1/2” 1/2” 1-pole Feed Box (AWG/kcmil) Equipment Product<br />

Rating Spaces Spaces Spaces Spaces Spaces Front Type Type Number Cu-Al Ground Kit Number<br />

30 4 2 8 4 8 Flush Front Top 3A 6-1 TGK12 included TM830FCUGEN<br />

Bottom<br />

30 4 2 8 4 8 Surface Front Top 3A 6-1 TGK12 included TM830SCUGEN<br />

Bottom<br />

60 4 2 8 4 8 Flush Front Top 3A 6-1 TGK12 included TM860FCUGEN<br />

Bottom<br />

60 4 2 8 4 8 Surface Front Top 3A 6-1 TGK12 included TM860SCUGEN<br />

Bottom<br />

Generator Panels, Two Interlocked Main Breakers Factory Installed<br />

Outdoor (NEMA 3R) Enclosure<br />

Main 1 Pole, 2 Pole, 1 Pole, 2 Pole, Total Main Wire Size<br />

Ampere 1” 1” 1/2” 1/2” 1-pole Feed Box (AWG/kcmil) Equipment Product<br />

Rating Spaces Spaces Spaces Spaces Spaces Type Number Cu-Al Ground Kit Number<br />

30 4 2 8 4 8 Top R2A 6-1 TGK12 included TM830RCUGEN<br />

60 4 2 8 4 8 Top R2A 6-1 TGK12 included TM860RCUGEN<br />

Riser Panels<br />

Indoor (NEMA 1) Enclosure<br />

Main 1 Pole, 2 Pole, 1 Pole, 2 Pole, Total Main Wire Size<br />

Ampere 1” 1” 1/2” 1/2” 1-pole Feed Box (AWG/kcmil) Equipment Product<br />

Rating Spaces Spaces Spaces Spaces Spaces Front Type Type Number Cu-Al Ground Kit Number<br />

125 20 10 40 20 40 Combination Top 9A 6-2/0 TGK12 (order TLM2012CCURP<br />

Flush/Surface Front<br />

separately)<br />

Tap kits required, order separately. See page 1-29.<br />

Auxiliary gutters available. See page 1-29.<br />

Spa Panels<br />

Outdoor (NEMA 3R) Enclosure<br />

Main 1 Pole, 2 Pole, 1 Pole, 2 Pole, Total Main Wire Size<br />

Ampere 1” 1” 1/2” 1/2” 1-pole Load Center Feed Box (AWG/kcmil) Equipment Product<br />

Rating Spaces Spaces Spaces Spaces Spaces Type Type Number Cu-Al Ground Kit Number<br />

125 4 2 8 4 8 Factory Included Top 1-2/0 TGL1 installed TL412R250GF<br />

50A GFCI Bottom<br />

125 4 2 8 4 8 Factory Included Top 1-2/0 TGL1 installed TL412R260GF<br />

60A GFCI Bottom<br />

Twist Lock Power Inlets<br />

Product<br />

Receptacles Amps Volts UL Number<br />

L14-20 20 120/240 Canada, US T020N<br />

L14-30 30 120/240 Canada, US T030N<br />

CS637 50 120/240 Canada, US T050N<br />

Rev. 11/13<br />

Data subject to change<br />

without notice<br />

www.geindustrial.com<br />

<strong>BuyLog</strong> <strong>Catalog</strong><br />

1-17


Load Centers and Circuit Breakers<br />

PowerMark Gold Meter Socket Load Centers<br />

Single-Phase, Three-Wire, 120/240 Vac<br />

With Bonded Neutrals<br />

Section 1<br />

Meter Socket LC<br />

1PH<br />

Ring Type<br />

Meter Main<br />

NEMA 3R<br />

Designed and manufactured for quality applications, these<br />

PowerMark Gold Meter Socket Load Centers are a superior<br />

solution to specific applications. Increased durability and<br />

reliability, maximum circuit layout flexibility and ease of<br />

installation add up to lower total installed cost.<br />

The Ringless UL Style meter socket load centers (Florida Meter<br />

Group, Georgia Power, Others) are specifically designed to meet<br />

UL requirements as well as some special features required by specific<br />

utilities. If your local utility does not require specific approval<br />

and you need a ringless meter socket load center, use the Florida<br />

Meter Group style.<br />

TSM2020CFCU<br />

Main<br />

Ampere 1 Pole, 2 Pole, 1 Pole, 2 Pole, Total 1-pole Enclosure Bypass UL Agency Product<br />

Rating 1” Spaces 1” Spaces 1/2” Spaces 1/2” Spaces Spaces Type Front Type Type Incoming Certification Number<br />

Meter Main - Ring Type, Field Installed Mains<br />

100 2 1 4 1 4 Outdoor Semi-Flush None OH/UG UL TSL210CFCU 1<br />

(NEMA 3R)<br />

EUSERC<br />

100 2 1 4 1 4 Outdoor Surface 2 None OH/UG UL TSL210CSCU 1,2,3<br />

(NEMA 3R)<br />

EUSERC<br />

125 4 2 6 3 6 Outdoor Surface 2 None OH/UG UL TSL412CSCU 1,2,3<br />

(NEMA 3R)<br />

EUSERC<br />

200 4 2 6 3 6 Outdoor Semi-Flush None OH/UG UL TSL420CFCU 1,4,5<br />

(NEMA 3R)<br />

200 4 2 6 3 6 Outdoor Surface 2 None OH/UG UL TSL420CSCU 1,2,3,4<br />

(NEMA 3R)<br />

EUSERC<br />

Meter Main - Factory Installed Mains<br />

100 0 0 0 0 0 Outdoor Surface 2 None OH/UG UL TM10RMC 2<br />

(NEMA 3R)<br />

125 0 0 0 0 0 Outdoor Surface 2 None OH/UG UL TM12RMC 2<br />

(NEMA 3R)<br />

150 0 0 0 0 0 Outdoor Surface 2 None OH/UG UL TM15RMC 2<br />

(NEMA 3R)<br />

200 0 0 0 0 0 Outdoor Surface 2 None OH/UG UL TM20RMC 2<br />

(NEMA 3R)<br />

1 Accepts field installed fifth jaw terminal in the 3 or 9 o’clock position. Product number TJAW53; order separately.<br />

2 Devices include removable closing cap. Order hub separately. See page 1-27.<br />

3 Surface mounted units have two hub provisions on top end wall.<br />

4 THQL and THHQL only, 125 amp max. TQDL is obsolete.<br />

5 Restricted<br />

EUSERC<br />

Application Data<br />

Main Wire Size<br />

Product Box Unit Width Unit Height Depth Factory Inst. Field Inst. (AWG/kcmil) Equipment<br />

Number Number (in inches) (in inches) (in inches) Svcs Disc Svcs Disc Cu-Al Ground Kit<br />

TSL210CFCU R12 14 23-1/2 4-7/8 THQP/THQL 6-2/0 TGL1 installed<br />

TSL210CSCU R12 14 23-1/2 4-7/8 THQP/THQL 6-2/0 TGL1 installed<br />

TSL412CSCU R12 14 23-1/2 4-7/8 THQP/THQL 6-2/0 TGL1 installed<br />

TSL420CFCU R14 14 30-3/4 5-3/4 THQP/THQL 1-250 TGL1 installed<br />

TSL420CSCU R14 14 30-3/4 5-3/4 THQP/THQL 1-250 TGL1 installed<br />

TM10RMC R32 16 17 5 TQD Field Installed 4 2-250<br />

TM12RMC R32 16 17 5 TQD Field Installed 4 2-250<br />

TM15RMC R32 16 17 5 TQD Field Installed 4 2-250<br />

TM20RMC R32 16 17 5 TQD Field Installed 4 2-250<br />

1-18 <strong>BuyLog</strong> <strong>Catalog</strong> www.geindustrial.com<br />

Rev. 11/13<br />

Data subject to change<br />

without notice


Load Centers and Circuit Breakers<br />

PowerMark Gold Meter Socket Load Centers<br />

Single-Phase, Three-Wire, 120/240 Vac<br />

With Bonded Neutrals<br />

Ring Type - Farm Panel - Main Breaker<br />

Main<br />

Ampere 1 Pole, 2 Pole, 1 Pole, 2 Pole, Total 1-pole Enclosure Front Bypass UL Agency Product<br />

Rating 1” Spaces 1” Spaces 1/2” Spaces 1/2” Spaces Spaces Type Front Type Type Incoming Certification Number<br />

200 4 2 8 3 8 Outdoor Surface None OH/UG UL TSF420CSCU 1,2<br />

(NEMA 3R)<br />

EUSERC<br />

1 Devices include removable closing cap. Order hub separately. See page 1-27.<br />

2 Separate field mounted service disconnect can be added, THQL/THHQL. See wiring diagram on page 1-35.<br />

Application Data<br />

Main Wire Size<br />

Product Box Unit Width Unit Height Depth Factory Inst. Field Inst. (AWG/kcmil) Equipment<br />

Number Number (in inches) (in inches) (in inches) Svcs Disc Svcs Disc Cu-Al Ground Kit<br />

TSF420CSCU R16 16-3/4 33 6-3/16 THQMV THQL/THHQL 1-300 TGK12 (order separately)<br />

Ring Type Feed-Thru - Main Breaker<br />

Main<br />

Ampere 1 Pole, 2 Pole, 1 Pole, 2 Pole, Total 1-pole Enclosure Front Bypass UL Agency Product<br />

Rating 1” Spaces 1” Spaces 1/2” Spaces 1/2” Spaces Spaces Type Type Type Incoming Certification Number<br />

150 4 2 8 3 8 Outdoor Surface None OH/UG UL TSM415CSCU 1<br />

(NEMA 3R<br />

150 8 4 16 6 16 Outdoor Surface None OH/UG UL TSM815CSCU 1<br />

(NEMA 3R)<br />

150 8 4 16 6 16 Outdoor Surface None OH/UG UL TSM815CSFL 1<br />

(NEMA 3R)<br />

200 4 2 8 3 8 Outdoor Surface None OH/UG UL TSM420CSCU 1<br />

(NEMA 3R)<br />

200 8 4 16 6 16 Outdoor Surface None OH/UG UL TSM820CSCU 1<br />

(NEMA 3R<br />

200 8 4 16 6 16 Outdoor Surface None OH/UG UL TSM820CSFL 1<br />

1 Devices include removable closing cap. Order hub separately. See page 1-27.<br />

Application Data<br />

(NEMA 3R)<br />

Section 1<br />

Meter Socket LC<br />

1PH<br />

Ring Type<br />

Farm Panel<br />

Main Breaker<br />

NEMA 3R<br />

Main Wire Size<br />

Product Box Unit Width Unit Height Depth Factory Inst. (AWG/kcmil) Equipment<br />

Number Number (in inches) (in inches) (in inches) Svcs Disc Cu-Al Ground Kit<br />

TSM415CSCU R36 14 28-1/2 4-1/2 THQMV 6-350 TGL2 included<br />

TSM815CSCU R16 16-3/4 33 6-3/16 THQMV 1-300 TGK12 (order separately)<br />

TSM815CSFL R37B 14 31-3/4 4-1/2 THQMV 6-350 TGK24 included<br />

TSM420CSCU R36 14 28-1/2 4-1/2 THQMV 6-350 TGL2 included<br />

TSM820CSCU R16 16-3/4 33 6-3/16 THQMV 6-350 TGK12 (order separately)<br />

TSM820CSFL R37B 14 31-3/4 4-1/2 THQMV 6-350 TGK24 included<br />

Rev. 11/13<br />

Data subject to change<br />

without notice<br />

www.geindustrial.com<br />

<strong>BuyLog</strong> <strong>Catalog</strong><br />

1-19


Load Centers and Circuit Breakers<br />

PowerMark Gold Meter Socket Load Centers<br />

Single-Phase, Three-Wire, 120/240 Vac<br />

With Bonded Neutrals<br />

Ring Type - Side by Side - Main Breaker - OH/UG<br />

Main<br />

Ampere 1 Pole, 2 Pole, 1 Pole, 2 Pole, Total 1-pole Enclosure Bypass UL Agency Product<br />

Rating 1” Spaces 1” Spaces 1/2” Spaces 1/2” Spaces Spaces Type Front Type Type Incoming Certification Number<br />

100 16 8 32 14 32 Outdoor Semi-Flush None OH/UG UL/EUSERC TSM1610CFCU 1<br />

125 12 6 24 12 24 Outdoor Semi-Flush None OH/UG UL/EUSERC TSM1212CFCU 1<br />

125 16 8 32 14 32 Outdoor Semi-Flush None OH/UG UL/EUSERC TSM1612CFCU 1<br />

200 20 10 40 18 40 Outdoor Semi-Flush None OH/UG UL/EUSERC TSM2020CFCU 1<br />

100 16 8 32 14 32 Outdoor Surface None OH/UG UL/EUSERC TSM1610CSCU 1,2,3<br />

125 12 6 24 12 24 Outdoor Surface None OH/UG UL/EUSERC TSM1212CSCU 1,2,3<br />

125 16 8 32 14 32 Outdoor Surface None OH/UG UL/EUSERC TSM1612CSCU 1,2,3<br />

200 20 10 40 18 40 Outdoor Surface None OH/UG UL/EUSERC TSM2020CSCU 1,2,3<br />

1 Accepts field installed fifth jaw terminal in the 3 or 9 o’clock position. Product number TJAW53; order separately.<br />

2 Devices include removable closing cap. Order hub separately. See page 1-27.<br />

3 Surface mounted units have two hub provisions on top end wall.<br />

Application Data<br />

Main Wire Size<br />

Box Unit Width Unit Height Depth Factory Inst. (AWG/kcmil) Equipment<br />

Product Number Number (in inches) (in inches) (in inches) Svcs Disc Cu-Al Ground Kit<br />

TSM1610CFCU R19 14-3/4 28-1/2 7-5/16 THHQL 12-2/0 TGK12 (order separately)<br />

TSM1212CFCU R19 14-3/4 28-1/2 7-5/16 THHQL 12-2/0 TGK12 (order separately)<br />

TSM1612CFCU R19 14-3/4 28-1/2 7-5/16 THHQL 12-2/0 TGK12 (order separately)<br />

TSM2020CFCU R17 16-3/4 34-1/4 7-5/16 THQMV 1-300 TGK12 (order separately)<br />

TSM1610CSCU R20 14-3/4 27-5/16 5-7/16 THHQL 12-2/0 TGK12 (order separately)<br />

TSM1212CSCU R20 14-3/4 27-5/16 5-7/16 THHQL 12-2/0 TGK12 (order separately)<br />

TSM1612CSCU R20 14-3/4 27-5/16 5-7/16 THHQL 12-2/0 TGK12 (order separately)<br />

TSM2020CSCU R18 14-3/4 33 6-5/16 THQMV 1-300 TGK12 (order separately)<br />

Ring Type - Extra Wide - Main Breaker<br />

Main<br />

Ampere 1 Pole, 2 Pole, 1 Pole, 2 Pole, Total 1-pole Enclosure Bypass UL Agency Product<br />

Rating 1” Spaces 1” Spaces 1/2” Spaces 1/2” Spaces Spaces Type Front Type Type Incoming Certification Number<br />

200 32 16 16 6 40 Outdoor Surface None UG UL/EUSERC TSM3220UWCU 2<br />

200 40 20 0 0 40 Outdoor Surface None UG UL/EUSERC TSM4020UWCU 2<br />

2 Devices include removable closing cap. Order hub separately. See page 1-27.<br />

Application Data<br />

Main Wire Size<br />

Box Unit Width Unit Height Depth Factory Inst. (AWG/kcmil) Equipment<br />

Product Number Number (in inches) (in inches) (in inches) Svcs Disc Cu-Al Ground Kit<br />

TSM3220UWCU R28 22-1/2 27-7/8 6-1/4 THQMV 1-300 TGK12 (order separately)<br />

TSM4020UWCU R29 22-1/2 34-7/8 6-1/4 THQMV 1-300 TGK12 (order separately)<br />

Ring Type - Top/Bottom - Main Breaker<br />

Main<br />

Ampere 1 Pole, 2 Pole, 1 Pole, 2 Pole, Total 1-pole Enclosure Bypass UL Agency Product<br />

Rating 1” Spaces 1” Spaces 1/2” Spaces 1/2” Spaces Spaces Type Front Type Type Incoming Certification Number<br />

200 24 12 36 18 42 Outdoor Semi-Flush None UG UL/EUSERC TSM2420UF42 1<br />

200 32 14 16 6 40 Outdoor Semi-Flush None UG UL/EUSERC TSM3220UFCU<br />

225 20 10 40 18 40 Outdoor Semi-Flush None UG UL/EUSERC TSM2022UFCU<br />

225 32 14 16 6 40 Outdoor Semi-Flush None UG UL/EUSERC TSM3222UFCU<br />

200 24 12 36 18 42 Outdoor Surface None UG UL/EUSERC TSM2420US42 1,2,3<br />

200 32 14 16 6 40 Outdoor Surface None UG UL/EUSERC TSM3220USCU 1<br />

225 20 10 40 18 40 Outdoor Surface None UG UL/EUSERC TSM2022USCU 1<br />

225 32 14 16 6 40 Outdoor Surface None UG UL/EUSERC TSM3222USCU 1<br />

1 Accepts field installed fifth jaw terminal in the 3 or 9 o’clock position. Product number TJAW53; order separately.<br />

2 Devices include removable closing cap. Order hub separately. See page 1-27.<br />

3 Surface mounted units have two hub provisions on top end wall.<br />

Application Data<br />

Section 1<br />

Meter Socket LC<br />

1PH<br />

Ring Type<br />

Narrow, Wide, Over/Under<br />

Main Breaker<br />

NEMA 3R<br />

Main Wire Size<br />

Box Unit Width Unit Height Depth Factory Inst. (AWG/kcmil) Equipment<br />

Product Number Number (in inches) (in inches) (in inches) Svcs Disc Cu-Al Ground Kit<br />

TSM2420UF42 R17 16-3/4 34-1/4 7-5/16 THQMV 1-4/0 TGK12 (order separately)<br />

TSM3220UFCU R27 14-9/16 43-5/8 7-3/16 THQMV 1-300 TGK12 (order separately)<br />

TSM2022UFCU R21 14-9/16 43-5/8 7-3/16 THQMV 1-300 TGK12 (order separately)<br />

TSM3222UFCU R22 16-3/16 48-1/8 7-3/16 THQMV 1-300 TGK12 (order separately)<br />

TSM2420US42 R17 16-3/4 34-1/4 7-5/16 THQMV 1-4/0 TGK12 (order separately)<br />

TSM3220USCU R27 14-9/16 48-1/8 6-3/16 THQMV 1-300 TGK12 (order separately)<br />

TSM2022USCU R26 14-9/16 43-5/8 6-3/16 THQMV 1-300 TGK12 (order separately)<br />

TSM3222USCU R27 14-9/16 48-1/8 6-3/16 THQMV 1-300 TGK12 (order separately)<br />

1-20 <strong>BuyLog</strong> <strong>Catalog</strong> www.geindustrial.com<br />

Rev. 11/13<br />

Data subject to change<br />

without notice


Load Centers and Circuit Breakers<br />

PowerMark Gold Meter Socket Load Centers<br />

Single-Phase, Three-Wire, 120/240 Vac<br />

With Bonded Neutrals<br />

Section 1<br />

Meter Socket LC<br />

1PH<br />

Ringless with Bypass<br />

Xcel Energy<br />

NEMA 3R<br />

Ringless with Bypass - Xcel Energy<br />

Main<br />

Ampere 1 Pole, 2 Pole, 1 Pole, 2 Pole, Total 1-pole Enclosure Main Bypass UL Agency Product<br />

Rating 1” Spaces 1” Spaces 1/2” Spaces 1/2” Spaces Spaces Type Type Front Type Type Incoming Certification Number<br />

125 4 2 8 3 8 Outdoor MLO Surface Horn Bypass OH/UG Xcel/UL TSLR412CSCU 1<br />

(NEMA 3R)<br />

125 4 2 6 3 6 Outdoor MLO Surface 1 Lever OH/UG Xcel/UL TSLB412CSCU 1<br />

(NEMA 3R)<br />

Bypass<br />

125 12 6 24 10 24 Outdoor MB Surface Horn Bypass OH/UG Xcel/UL TSMR1212CSCU 1<br />

(NEMA 3R)<br />

125 12 6 24 12 24 Outdoor MB Surface Lever OH/UG Xcel/UL TSMB1212CSCU 1<br />

(NEMA 3R)<br />

Bypass<br />

150 4 2 8 3 8 Outdoor MB Surface Horn Bypass OH/UG Xcel/UL TSMR415CSCU<br />

(NEMA 3R)<br />

150 20 10 40 18 40 Outdoor MB Surface Horn Bypass OH/UG Xcel/UL TSMR2015CSCU 1<br />

(NEMA 3R)<br />

150 20 10 40 18 40 Outdoor MB Surface Lever OH/UG Xcel/UL TSMB2015CSCU 1<br />

(NEMA 3R)<br />

Bypass<br />

200 4 2 6 3 6 Outdoor MLO Surface 1 Lever OH/UG Xcel/UL TSLB420CSCU 1<br />

(NEMA 3R)<br />

Bypass<br />

200 4 2 8 3 8 Outdoor MLO Surface Horn Bypass OH/UG Xcel/UL TSLR420CSCU 1<br />

(NEMA 3R)<br />

200 4 2 8 3 8 Outdoor MB Surface Horn Bypass OH/UG Xcel/UL TSMR420CSCU<br />

(NEMA 3R)<br />

200 20 10 40 18 40 Outdoor MB Surface Horn Bypass OH/UG Xcel/UL TSMR2020CSCU 1<br />

(NEMA 3R)<br />

200 20 10 40 18 40 Outdoor MB Surface Lever OH/UG Xcel/UL TSMB2020CSCU 1<br />

(NEMA 3R)<br />

Bypass<br />

1 Devices include removable closing cap. Order hub separately. See page 1-27.<br />

Application Data<br />

Main Wire Size<br />

Box Unit Width Unit Height Depth Factory Inst. (AWG/kcmil) Equipment<br />

Product Number Number (in inches) (in inches) (in inches) Svcs Disc Cu-Al Ground Kit<br />

TSLR412CSCU R31 14-9/16 33-9/16 6-3/16 Field Installed 2 6-350 TGK12 (order separately)<br />

TSLB412CSCU R12 14 23-1/2 4-7/8 Field Installed 2 6-350 TGL1 installed<br />

TSMR1212CSCU R30 14-9/16 40-1/2 6-3/16 THHQL 6-350 TGK12 (order separately)<br />

TSMB1212CSCU R20 14-3/4 27-5/16 5-7/16 THHQL 12-2/0 TGK12 (order separately)<br />

TSMR415CSCU R31 14-9/16 33-9/16 6-3/16 THQMV 6-350 TGK12 installed<br />

TSMR2015CSCU R30 14-9/16 40-1/2 6-3/16 THQMV 6-350 TGK12 (order separately)<br />

TSMB2015CSCU R18 14-3/4 33 6-5/16 THQMV 1-300 TGK12 (order separately)<br />

TSLB420CSCU R14 14 30-3/4 5-3/4 Field Installed 2 6-350 TGL1 installed<br />

TSLR420CSCU R31 14-9/16 33-9/16 6-3/16 Field Installed 2 6-350 TGK12 (order separately)<br />

TSMR420CSCU R31 14-9/16 33-9/16 6-3/16 THQMV 6-350 TGK12 installed<br />

TSMR2020CSCU R30 14-9/16 40-1/2 6-3/16 THQMV 6-350 TGK12 (order separately)<br />

TSMB2020CSCU R18 14-3/4 33 6-5/16 THQMV 1-300 TGK12 (order separately)<br />

2 THQL and THHQL only. 125 amp max. TQDL is obsolete.<br />

Rev. 11/13<br />

Data subject to change<br />

without notice<br />

www.geindustrial.com<br />

<strong>BuyLog</strong> <strong>Catalog</strong><br />

1-21


Load Centers and Circuit Breakers<br />

PowerMark Gold Meter Socket Load Centers<br />

Single-Phase, Three-Wire, 120/240 Vac<br />

With Bonded Neutrals<br />

Georgia Power Ringless - Main Breaker<br />

Main<br />

Ampere 1 Pole, 2 Pole, 1 Pole, 2 Pole, Total 1-pole Enclosure Bypass UL Agency Product<br />

Rating 1” Spaces 1” Spaces 1/2” Spaces 1/2” Spaces Spaces Type Front Type Type Incoming Certification Number<br />

150 – – – – – Outdoor Surface None OH/UG UL/GP TSMR015CSGP 1,4<br />

(NEMA 3R)<br />

200 – – – – – Outdoor Surface None OH/UG UL/GP TSMR020CSGP 1,4<br />

(NEMA 3R)<br />

150 4 2 8 3 8 Outdoor Surface None OH/UG UL/GP TSMR415CSCUGP 1,4<br />

(NEMA 3R)<br />

200 4 2 8 3 8 Outdoor Surface None OH/UG UL/GP TSMR420CSCUGP 1,4<br />

(NEMA 3R)<br />

Application Data<br />

Main Wire Size<br />

Box Unit Width Unit Height Depth Factory Inst. (AWG/kcmil) Equipment<br />

Product Number Number (in inches) (in inches) (in inches) Svcs Disc Cu-Al Ground Kit<br />

TSMR015CSGP R32A 18-7/8 18-9/16 5 THQD 2-250 –<br />

TSMR020CSGP R32A 18-7/8 18-9/16 5 THQD 2-250 –<br />

TSMR415CSCUGP R40 14 32 4-1/2 THQMV 6-350 TGL2 included<br />

TSMR420CSCUGP R40 14 32 4-1/2 THQMV 6-350 TGL2 included<br />

Florida Meter Group MSLC Ringless - Main Breaker<br />

Main<br />

Ampere 1 Pole, 2 Pole, 1 Pole, 2 Pole, Total 1-pole Enclosure Bypass UL Agency Product<br />

Rating 1” Spaces 1” Spaces 1/2” Spaces 1/2” Spaces Spaces Type Front Type Type Incoming Certification Number<br />

150 4 2 8 3 8 Outdoor Surface None OH/UG UL/FMG TSMR415CSFLFMG<br />

(NEMA 3R)<br />

200 4 2 8 3 8 Outdoor Surface None OH/UG UL/FMG TSMR420CSFLFMG<br />

(NEMA 3R)<br />

150 8 4 16 6 16 Outdoor Surface None OH/UG UL/FMG TSMR815CSFLFMG 4<br />

(NEMA 3R)<br />

200 8 4 16 6 16 Outdoor Surface None OH/UG UL/FMG TSMR820CSFLFMG 4<br />

(NEMA 3R)<br />

200 20 4 40 18 40 Outdoor Surface None OH/UG UL/FMG TSMR2020CSCUFMG 2<br />

(NEMA 3R)<br />

Application Data<br />

Section 1<br />

Meter Socket LC<br />

1PH<br />

Ringless<br />

Georgia Power<br />

Florida Meter Group<br />

Main Breaker<br />

NEMA 3R<br />

Main Wire Size<br />

Box Unit Width Unit Height Depth Factory Inst. (AWG/kcmil) Equipment<br />

Product Number Number (in inches) (in inches) (in inches) Svcs Disc Cu-Al Ground Kit<br />

TSMR415CSFLFMG R36A 14 28-1/2 4-1/2 THQMV 6-350 TGL2 included<br />

TSMR420CSFLFMG R36A 14 28-1/2 4-1/2 THQMV 6-350 TGL2 included<br />

TSMR815CSFLFMG R37A 14 31-3/4 4-1/2 THQMV 6-350 TGK24 included<br />

TSMR820CSFLFMG R37A 14 31-3/4 4-1/2 THQMV 6-350 TGK24 included<br />

TSMR2020CSCUFMG R40 3 14 34-1/2 4-1/2 THQMV 6-350 TGK24 included<br />

1 Use FMG unit if Ringless standard UL design is required by your local utility.<br />

2 No feed through lugs.<br />

3 Knock outs are the same as R36A.<br />

4 Feed-thru lugs provided.<br />

1-22 <strong>BuyLog</strong> <strong>Catalog</strong> www.geindustrial.com<br />

Rev. 11/13<br />

Data subject to change<br />

without notice


Load Centers and Circuit Breakers<br />

PowerMark Gold Meter Socket Load Centers<br />

Single-Phase, Three-Wire, 120/240 Vac<br />

With Bonded Neutrals<br />

Section 1<br />

Meter Socket LC<br />

1PH<br />

Class 320<br />

NEMA 3R<br />

Class 320<br />

Main 1 Pole, 2 Pole, 1 Pole, 2 Pole, Total<br />

Ampere 1” 1” 1/2” 1/2” 1-pole Enclosure Bypass UL Agency Product<br />

Rating Spaces Spaces Spaces Spaces Spaces Type Front Type Type Incoming Certification Number<br />

320 24 12 32 14 40 Outdoor Surf/Semi None UG UL TM2432RMS 1,2,3<br />

(NEMA 3R)<br />

400 0 0 0 0 0 Outdoor Surf/Semi Lever Bypass UG UL TSDR040UFCU 4<br />

(NEMA 3R)<br />

300 8 4 16 6 16 Outdoor Surface Lever Bypass UG UL TSDR830USCU 4<br />

(NEMA 3R)<br />

FMG<br />

400 8 4 16 6 16 Outdoor Surface Lever Bypass UG UL TSDR840UFCU 4<br />

(NEMA 3R)<br />

FMG<br />

400 24 12 32 14 40 Outdoor Surf/Semi K-4 Bolt-In UG UL TM2440RMKS 1,2,3<br />

(NEMA 3R)<br />

Meter Provision<br />

400 24 12 32 14 40 Outdoor Surf/Semi Lever Bypass UG UL TM2440RMRS 1,2,3<br />

(NEMA 3R)<br />

400 24 12 32 14 40 Outdoor Surf/Semi None UG UL TM2440RMS 1,2,3<br />

(NEMA 3R)<br />

EUSERC<br />

400 24 12 32 14 40 Outdoor Surf/Semi Lever Bypass UG UL TMH2440RMRS 1,2,3,4<br />

(NEMA 3R)<br />

Xcel<br />

400 24 12 32 14 40 Outdoor Surf/Semi None UG UL TMH2440RMS 1,2,3,4<br />

(NEMA 3R)<br />

320 0 0 0 0 0 Outdoor Surf/Semi Lever Bypass UG UL TSD032UFCU 4<br />

(NEMA 3R)<br />

320 24 12 32 14 42 Outdoor Surf/Semi Link Bypass UG UL TSDA2432UC42 4<br />

(NEMA 3R)<br />

EUSERC<br />

400 24 12 32 14 42 Outdoor Surf/Semi Link Bypass UG UL TSDA2440UC42 4<br />

(NEMA 3R)<br />

EUSERC<br />

1 200A main breaker factory installed. Space provided for field mounted TQD-WL sub feed.<br />

2 For semi-flush applications, order surface enclosure load center and field installed kit, Product number SF400.<br />

3 Stud provisions only provided.<br />

4 22 kAIC.<br />

Application Data<br />

Main Wire Size<br />

Product Box Unit Width Unit Height Depth Factory Inst. Field Inst. (AWG/kcmil) Equipment<br />

Number Ringless Number (in inches) (in inches) (in inches) Main Breaker Main Breaker Cu-Al Ground Kit<br />

TM2432RMS No R24 30-1/4 40 6 TQD THQL (1) 800 or (2) 400 compression type; (2) TGL2<br />

(1) 1000 or (2) compression type; (order separately)<br />

(1) 1000 or (2) 350 pressure type<br />

TM2440RMS No R24 30-1/4 40 6 TQD TQD (1) 800 or (2) 400 compression type; (2) TGL2<br />

(1) 1000 or (2) 350 pressure type (order separately)<br />

TMH2440RMS No R24 30-1/4 40 6 THQD THQD (1) 800 or (2) 400 compression type; (2) TGL2<br />

(1) 1000 or (2) 350 pressure type (order separately)<br />

TSDA2432UC42 No R24 30-1/4 40 6 THQD THQL/THHQL (1) 800 or (2) 400 compression type (2) TGL2<br />

(order separately)<br />

TSDA2440UC42 No R24 30-1/4 40 6 THQD TQD/THQD (1) 800 or (2) 400 compression type (2) TGL2<br />

(order separately)<br />

TSD032UFCU No R33 30-1/4 33 6-3/32 THQD THQL/THHQL (1) 800 or (2) 400 compression type (2) TGL2<br />

(order separately)<br />

TM2440RMKS Yes R23 30-1/4 40 6 TQD TQD (1) 800 or (2) 400 compression type; (2) TGL2<br />

(1) 1000 or (2) 350 pressure type (order separately)<br />

TM2440RMRS Yes R24 30-1/4 40 6 TQD TQD (1) 800 or (2) 400 compression type; (2) TGL2<br />

(1) 1000 or (2) 350 pressure type (order separately)<br />

TMH2440RMRS Yes R24 30-1/4 40 6 THQD THQD (1) 800 or (2) 400 compression type; (2) TGL2<br />

(1) 1000 or (2) 350 pressure type (order separately)<br />

TSDR040UFCU Yes R33 30-1/4 33 6-3/32 THQD TQD/THQD (1) 800 or (2) 400 compression type (2) TGL2<br />

(order separately)<br />

TSDR840UFCU Yes R33 30-1/4 33 6-3/32 THQD TQD/THQD (1) 800 or (2) 400 compression type (2) TGL2<br />

(order separately)<br />

Rev. 11/13<br />

Data subject to change<br />

without notice<br />

www.geindustrial.com<br />

<strong>BuyLog</strong> <strong>Catalog</strong><br />

1-23


Load Centers and Circuit Breakers<br />

PowerMark Gold and Plus Load Centers<br />

Circuit Breakers<br />

Field Installed Accessories<br />

Section 1<br />

PowerMark Gold Main Circuit Breaker Kit<br />

For use with 125A PowerMark Gold load Centers; 22kAIC RMS symmetrical.<br />

Product<br />

Description<br />

Number<br />

Main Circuit Breaker Kit - Order appropriate THQL TQMH000 1<br />

10kAIC or THHQL 22kAIC breakers separately<br />

1 Please review the footnotes listed with the individual Load Center product numbers for proper parts needed to<br />

convert to a main circuit breaker. This main breaker base is only applicable for 16 circuit and larger 125 amp load<br />

centers, 12 circuit load centers with A C24 suffix, and the TLM812RCU2.<br />

TQMH000<br />

PowerMark Plus Equipment Ground Kits<br />

Product<br />

Description Standard Package Quantity Number<br />

(4) 14-8Cu/12-8AL, 20 TGL1<br />

(3) 14-4Cu/6-4AL<br />

(8) 14-8Cu/12-8AL, 20 TGL2 1<br />

(6) 14-4Cu/6-4AL<br />

(7) 14-8Cu/12-8AL, (3) 14-4Cu/6-4AL, 20 TGL8 1<br />

(2) 14-4Cu/12-4AL, (1) 14-2Cu/AL<br />

(1) 6-2/0Cu/Al Number of Terminals, 20 TGL20 2<br />

Equipment Ground Kits<br />

(3) 10-1/0 Cu/Al Number of Terminals 1 TNG3 3<br />

for 400 and 600 Amp<br />

(6) 10-1/0 Cu/Al Number of Terminals 1 TNG6 4<br />

for 400 and 600 Amp<br />

TGL2, TGL4 and TGL8 mount interchangeably<br />

2 Add-on Equipment Ground Lug (for use on any TGL Kit)<br />

3 Suitable for use with up to six TPLUG108 lugs or six crimp lugs per pole<br />

TGL2<br />

TGL20 combined with TGL1<br />

PowerMark Gold Equipment Ground and Isolated Ground Bar Kits 4,5<br />

Product<br />

Description Standard Package Quantity Number<br />

4-hole Ground 1 TGK4<br />

12-hole Ground 1 TGK12<br />

24-hole Ground 1 TGK24<br />

32-hole Ground 1 TGK32<br />

42-hole Ground 1 TGK42<br />

4 6-12 circuit indoor load centers use PowerMark Plus style neutrals and grounds<br />

5 Add TGKIS for isolated ground and mount to ground kit.<br />

TGK12<br />

TGK12 with TGKIS<br />

1-24<br />

<strong>BuyLog</strong> <strong>Catalog</strong><br />

www.geindustrial.com Rev. 11/13<br />

Data subject to change<br />

without notice


Load Centers and Circuit Breakers<br />

PowerMark Gold and Plus Load Centers<br />

Circuit Breakers<br />

Field Installed Accessories<br />

Section 1<br />

PowerMark Plus Neutral Kits<br />

Wire Standard Product<br />

Description Range Package Quantity Number<br />

400 & 600 Amp PowerMark Plus Neutral Kit (5) 14-1/0 1 TNLK1 1<br />

400 & 600 Amp PowerMark Plus Neutral Kit (3) 1-300 1 TNLK2 1<br />

Add-on neutral lug for 100-200 Amp PowerMark 6-2/0 1 286A8894G1<br />

Plus load centers<br />

Add-on neutral lug for 100-200 Amp PowerMark 1-300 Cu or 1 192A7663G13<br />

Plus load centers<br />

2/0-300 Al<br />

1 Suitable for use with up to six TPLUG108 lugs or six crimp lugs per pole<br />

192A7663G13<br />

286A8894G1<br />

PowerMark Gold Neutral Kits<br />

Wire Standard Product<br />

Description Range Package Quantity Number<br />

PowerMark Gold Neutral Kit - 6-2/0 1 TNLK20<br />

Mounted on top of neutral only<br />

PowerMark Gold Neutral Kit - 6-250 1 TNLK250<br />

Mounted on top of neutral only<br />

TNLK250<br />

PowerMark Gold Neutral/Ground Lug Kits<br />

Mounted on any neutral or ground position by removing the termination screw<br />

Wire Standard Product<br />

Description Range Package Quantity Number<br />

Neutral/Ground Lug Kit 6-2/0 1 TLK20<br />

Neutral/Ground Lug Kit 6-250 1 TLK250<br />

Neutral/Ground Lug Kit 6-300 1 TLK300<br />

TLK20<br />

TLK250<br />

Isolated Ground Bus Bars Equipment Ground Kit<br />

Standard<br />

Product<br />

Description Package Quantity Number<br />

Isolated Ground Bar Kit (order with 1 TGKIS<br />

TGK Equipment Ground Kits)<br />

Isolated Ground Bar Feet (Order with TGK8) 1 TGKIS2<br />

Subfeed Lug Kits<br />

Standard<br />

Product<br />

Description Package Quantity Number<br />

125A 2 Pole Plug-in 1 THLK2125<br />

150A 2 Pole Plug-in - For use with PowerMark Gold only 1 THLK2150<br />

200A 2 Pole Plug-in - For use with PowerMark Gold only 1 THLK2200<br />

125A 3 Pole Plug-in 1 THLK3125<br />

225A 3 Pole Plug-in - For use with 3 phase only 1 THLK3225<br />

TGK12 with TGKIS<br />

Sub-feed and Feed-thru Lugs<br />

UL Listed<br />

For use in load centers to economically supply power to a subpanel.<br />

Product<br />

Poles Ampere Rating Number<br />

2 125 THLK2125<br />

3 125 THLK3125<br />

2 150 THLK2150 1<br />

2 200 THLK2200 1<br />

3 225 THLK3225 2<br />

1 For use with PowerMark Gold load centers only<br />

2 For use with three-phase load centers only. Includes mounting base.<br />

THLK2125<br />

Rev. 11/13<br />

Data subject to change<br />

without notice<br />

www.geindustrial.com <strong>BuyLog</strong> <strong>Catalog</strong> 1-25


Load Centers and Circuit Breakers<br />

PowerMark Gold and Plus Load Centers<br />

Circuit Breakers<br />

Field Installed Accessories<br />

Section 1<br />

PowerMark Plus Main Lug Kits<br />

Product<br />

Description Wire Range (Cu/Al) Number<br />

150 Amp PowerMark Plus Replacement Main Lug kit 2-3/0 THLK150<br />

200 Amp PowerMark Plus Replacement Main Lug kit 1-250 THLK200<br />

THLK200<br />

PowerMark Gold Main Lug Kits<br />

Product<br />

Description Wire Range (Cu/Al) Number<br />

125 Amp PowerMark Gold Replacement Main Lug kit 6-2/0 TMLK125<br />

200 Amp PowerMark Gold Replacement Main Lug kit 6-250 TMLK200<br />

225 Amp PowerMark Gold Replacement Main Lug kit 6-300 TMLK225<br />

For replacement of main lugs on 125 amp load centers; TLM load centers include main lugs.<br />

PowerMark Gold main lug kits - TMLK200<br />

Door Lock<br />

Standard<br />

Product<br />

Description Package Quantity Number<br />

For indoor load centers larger than 12 circuits (Does not fit TPL412) 10 TDL106<br />

TDL106<br />

Circuit Directory<br />

Standard<br />

Product<br />

Description Package Quantity Number<br />

Card and holder with pressure-sensitive backing. 1 TD42<br />

Mounts inside the door.<br />

TD42<br />

Touch-up Paint<br />

Standard<br />

Product<br />

Description Package Quantity Number<br />

12 3/4 oz. spray can of light gray enamel 1 TSP61<br />

TSP61<br />

1-26<br />

<strong>BuyLog</strong> <strong>Catalog</strong><br />

www.geindustrial.com Rev. 11/13<br />

Data subject to change<br />

without notice


Load Centers and Circuit Breakers<br />

PowerMark Gold and Plus Load Centers<br />

Circuit Breakers<br />

Field Installed Accessories<br />

Section 1<br />

Front Filler Plates<br />

Standard<br />

Product<br />

Description Package Quantity Number<br />

1/2” Front Filler Plate 100 TFH<br />

1” Front Filler Plate 50 TQLFP1<br />

Covers 1/2” rectangular breaker knockouts<br />

Covers 1” rectangular breaker knockouts<br />

TFH<br />

Universal Raintight Hubs<br />

Standard<br />

Product<br />

Description Base Size (in.) Package Quantity Number<br />

3/4” Diameter 3 10 TC75<br />

1” Diameter 3 10 TC100<br />

1-1/4” Diameter 3 10 TC125<br />

1-1/2” Diameter 3 10 TC150<br />

2” Diameter 3 10 TC200<br />

2-1/2” Diameter 3 10 TC250<br />

3” Diameter 3 5 TC300<br />

Closing Cap 3 10 TCCP<br />

2” Diameter 4 TCU27<br />

2-1/2” Diameter 4 TCU28<br />

3” Diameter 4 TCU30<br />

3-1/2” Diameter 4 TCU35<br />

4” Diameter 4 TCU40 1<br />

4” Cover Plate 4 TCUP<br />

1 For 40 and 42 circuit units in R8 boxes only.<br />

TC150<br />

Door Handle<br />

Standard<br />

Product<br />

Description Package Quantity Number<br />

Replacement Door Handle Universal 1 TRL22<br />

TRL22<br />

PowerMark Gold Cross Arm<br />

Standard<br />

Product<br />

Description Package Quantity Number<br />

Replacement cross arm for<br />

PowerMark Gold load centers 1 LCCROSSARM<br />

LCCROSSARM<br />

Rev. 11/13<br />

Data subject to change<br />

without notice<br />

www.geindustrial.com <strong>BuyLog</strong> <strong>Catalog</strong> 1-27


Load Centers and Circuit Breakers<br />

PowerMark Gold and Plus Load Centers<br />

Circuit Breakers<br />

Field Installed Accessories<br />

Section 1<br />

PowerMark Gold Main Breaker Retainers<br />

Product<br />

Description Breaker Type Number<br />

Travel Trailer Main Breaker Retainer Kit THQP THQPSBK<br />

for THQP Breakers<br />

For use on PowerMark Plus load centers with THQL THQLRK<br />

THQL Breakers 225A max<br />

For use with 12 - 42 circuit PowerMark Gold THQL THQLRK1<br />

load centers with THQL Breakers<br />

For use with 6 - 8 circuit PowerMark Gold THQL THQLRK2<br />

load centers with THQL Breakers<br />

For use with TM/TLM1212CCU Mod 2 current model THQL THQLRK3<br />

For use with 6 - 42 circuit PowerMark Gold THQL THQLRK4<br />

load centers with THQL Breakers. Similar to<br />

THQLRK1 but it does not take up a breaker space.<br />

For main lug load centers utilizing a back fed branch breaker as a main<br />

Handle Locks - Padlocking<br />

Product<br />

Description Breaker Type Number<br />

THQP Padlocking Handle Lock THQP TQPPL<br />

THQL Padlocking Handle Lock THQL THP100<br />

TQD Padlocking Handle Lock TQD TQDPLD1<br />

Snap on handle lock<br />

Padlock not included<br />

THQLRK<br />

THQLRK1<br />

THL103<br />

Handle Locks - Non Padlocking<br />

Product<br />

Description Breaker Type Number<br />

THQP Non Padlocking Handle Lock THQP TQPL<br />

THQL Non Padlocking Handle Lock THQL THL103<br />

Snap on handle lock<br />

Handle Ties<br />

Product<br />

Description Breaker Type Number<br />

Handle Ties for THQP Breakers - Solid Snap-on THQP THT1 1<br />

Trip Indicating<br />

Handle Ties for THQP Breakers - For 2 THQPs THQP THT2 1<br />

separated by 2 side-by-side THQPs<br />

TQB<br />

Snap-on Handle Tie - Trip Indicating TQC TQHT1 1<br />

TQL<br />

TQB<br />

Snap-on Handle Tie - Solid TQC THT104 1<br />

TQL<br />

TQB<br />

Multiwire Branch Breaker<br />

TQ3HTK 2<br />

TQC<br />

Handle Tie Kits<br />

TQ4HTK3<br />

TQL<br />

All multi-pole breakers have internal common trip<br />

Handle ties provide manual on-off capability only between one-pole devices<br />

1 For two single-pole breakers<br />

2 For three single-pole breakers - kit includes (10) pcs.<br />

3 For four single-pole breakers - kit includes (10) pcs.<br />

THT1<br />

THT104<br />

THT2<br />

TQHT1<br />

1-28<br />

<strong>BuyLog</strong> <strong>Catalog</strong><br />

www.geindustrial.com Rev. 11/13<br />

Data subject to change<br />

without notice


Load Centers and Circuit Breakers<br />

PowerMark Gold and Plus Load Centers<br />

Circuit Breakers<br />

Field Installed Accessories<br />

Section 1<br />

Load Center Hardware Kits Hardware<br />

Standard<br />

Product<br />

Description Package Quantity Number<br />

PowerMark Plus hardware kit: TQD THQD Main or 1 LCHDKIT<br />

THLK main lug kit in a TLM load center, installation<br />

instructions and front mounting screws<br />

Powermark Gold Bond Screw Kit Screw 100 - 200A 1 TBS<br />

Powermark Gold Bond Screw Kit 225A 1 TBS22<br />

Powermark Gold Hardware kit 1 THDWRKIT<br />

containing 20 front mounting screws<br />

Powermark Gold Hardware kit 1 THDWRKIT2<br />

containing 10 interior mounting screws<br />

Generator Interlock Kit<br />

Standard<br />

Product<br />

Description Package Quantity Number<br />

Load Center Generator Interlock Kit 1 THQLLX1<br />

MSLC Generator Interlock Kit 1 THQLLX4<br />

MSLC Generator Interlock Kit 1 THQLLX8CU<br />

MSLC Generator Interlock Kit 1 THQLLX8DR<br />

MSLC Generator Interlock Kit 1 THQLLX8FL<br />

PowerMark Gold Auxiliary Gutter Enclosures<br />

Description<br />

Product<br />

Number<br />

24” Auxiliary Gutter Enclosure TMAGB24<br />

28” Auxiliary Gutter Enclosure TMAGB28<br />

28” Auxiliary Gutter Enclosure Flush TMAGB28F<br />

33” Auxiliary Gutter Enclosure TMAGB33<br />

39” Auxiliary Gutter Enclosure TMAGB39<br />

43” Auxiliary Gutter Enclosure TMAGB43<br />

43” Deep Auxiliary Gutter Enclosure TMAGB43D<br />

PowerMark Gold Gutter Tap Kits<br />

Description<br />

Product<br />

Number<br />

250 kcmil Lugs Gutter Tap Kit - one kit per phase required TMGT250<br />

500 kcmil Lugs Gutter Tap Kit - one kit per phase required TMGT500<br />

750 kcmil Lugs Gutter Tap Kit - one kit per phase required - TMGT750<br />

Not for use with riser panels<br />

Meter Socket Load Center Flange Kits<br />

Description<br />

Semi-Flush Kit 400A for MSLC<br />

Semi-Flush Kit 400A for MSLC Adjustable<br />

Semi-Flush Kit 200A for MSLC Adjustable<br />

Product<br />

Number<br />

SF400<br />

SF400A<br />

SF200A<br />

Surge Protectors<br />

Description<br />

SurgePro AC 27KA Panel-Mount Surge Protector<br />

Product<br />

Number<br />

THQLSURGE<br />

Rev. 11/13<br />

Data subject to change<br />

without notice<br />

www.geindustrial.com <strong>BuyLog</strong> <strong>Catalog</strong> 1-29


Load Centers and Circuit Breakers<br />

PowerMark Gold and Plus Load Centers<br />

Circuit Breakers<br />

Wiring Diagrams<br />

A<br />

A<br />

Section 1<br />

G G G<br />

E<br />

Breaker Fill<br />

Breaker Symbol 1” THQL 1/2” THQP<br />

1 —<br />

1 2<br />

TL240SCU, RCU<br />

TL270SCU, RCU<br />

TL510RT<br />

Wire Range (AWG/kcmil)<br />

Terminal Symbol Cu Al<br />

o 14-8 12-8<br />

• 14-4 12-4<br />

A 6-2 6-2<br />

B 14-1/0 12-1/0<br />

C 6-2/0 6-2/0<br />

D 1-300 2/0-300<br />

E 1-300 1-300<br />

F 6-1 6-1<br />

G 6-3 6-3<br />

MAIN LUGS<br />

C<br />

TPL412C, TL412C, TPL412R, TL412R1,<br />

TL412R2, TL412R250GF, TL412R260GF<br />

MAIN LUGS<br />

C<br />

C<br />

TPL412CT, TL412CT<br />

TPL412RT, TL412RT1<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

C<br />

MAIN<br />

BREAKER<br />

E<br />

F<br />

MAIN<br />

BREAKER<br />

MAIN<br />

BREAKER<br />

SUB-FEED<br />

LUGS<br />

E<br />

TLM612FCU, SCU<br />

FCUD, SCUD, RCU<br />

TLM812FCU, SCU,<br />

FCUD, SCUD, RCU<br />

TM815RCUFL<br />

TM820RCUFL<br />

TM860FCUGEN, TLM830FCUGEN,<br />

TM860SCUGEN, TLM830SCUGEN,<br />

TM860RCUGEN, TLM830RCUGEN<br />

C C C C<br />

C<br />

E<br />

MAIN<br />

MAIN<br />

TM1210CCU, TM1212CCU, TLM1212CCU<br />

TM1210RCU, TM1212RCU, TLM1212RCU<br />

TLM2012CCURP<br />

MAIN<br />

C<br />

C<br />

MAIN<br />

E<br />

F<br />

F<br />

C<br />

C<br />

MAIN<br />

C<br />

TLM1612CCU, TM1612CCU, TM1612RCU<br />

TM1615CCU, TM1615RCU, TM1620CCU,<br />

TLM1620CCU, TLM1620RCU<br />

TLM812RCU2<br />

TM2420R42B<br />

1-30<br />

<strong>BuyLog</strong> <strong>Catalog</strong><br />

www.geindustrial.com Rev. 11/13<br />

Data subject to change<br />

without notice


Load Centers and Circuit Breakers<br />

PowerMark Gold and Plus Load Centers<br />

Circuit Breakers<br />

Wiring Diagrams<br />

MAIN<br />

C<br />

C<br />

Section 1<br />

MAIN<br />

E<br />

Breaker Fill<br />

Breaker Symbol 1” THQL 1/2” THQP<br />

1 —<br />

1 2<br />

Wire Range (AWG/kcmil)<br />

Terminal Symbol Cu Al<br />

o 14-8 12-8<br />

• 14-4 12-4<br />

A 6-2 6-2<br />

B 14-1/0 12-1/0<br />

C 6-2/0 6-2/0<br />

D 1-300 2/0-300<br />

E 1-300 1-300<br />

F 6-1 6-1<br />

G 6-3 6-3<br />

TM2010CCU, TM2010RCU<br />

MAIN<br />

TM2410CCU, TM2412CCU<br />

TM2412RCU, TLM2412CCU, TLM2412RCU<br />

C<br />

TM2020CCU, TM2020RCU<br />

TLM2020CCU, TLM2020RCU<br />

C<br />

MAIN<br />

TM2415RCU, TLM2415RCU<br />

E<br />

C<br />

C<br />

E<br />

C<br />

MAIN<br />

E<br />

MAIN<br />

MAIN<br />

C<br />

E<br />

MAIN<br />

TLM2420C42, TM2415C42<br />

TM3210CCU<br />

TM3215CCU, TM3215RCU<br />

TM3220CCU, TM3220RCU, TLM3220CCU<br />

C<br />

MAIN<br />

E<br />

C<br />

MAIN<br />

E<br />

C<br />

MAIN<br />

MAIN<br />

C<br />

TM4020CCU, TM4020RCU<br />

TLM4020CCU, TLM4020RCU<br />

TM4222RCU, TLM4222CCU<br />

TLM4222RCU, TM4222CCU<br />

TM12410<br />

TL12412<br />

C<br />

E<br />

MAIN<br />

TM3215C42, TLM3220C42, TM3220C42<br />

Rev. 11/13<br />

Data subject to change<br />

without notice<br />

www.geindustrial.com <strong>BuyLog</strong> <strong>Catalog</strong> 1-31


Load Centers and Circuit Breakers<br />

PowerMark Gold and Plus Load Centers<br />

Circuit Breakers<br />

Wiring Diagrams<br />

Section 1<br />

Breaker Fill<br />

Breaker Symbol 1” THQL 1/2” THQP<br />

1 —<br />

1 2<br />

MAIN<br />

C C D<br />

MAIN<br />

C C D<br />

Wire Range (AWG/kcmil)<br />

Terminal Symbol Cu Al<br />

o 14-8 12-8<br />

• 14-4 12-4<br />

A 6-2 6-2<br />

B 14-1/0 12-1/0<br />

C 6-2/0 6-2/0<br />

D 1-300 2/0-300<br />

E 1-300 1-300<br />

F 6-1 6-1<br />

G 6-3 6-3<br />

TL18415, TL18420<br />

TL24415, TM24415<br />

MAIN<br />

MAIN<br />

C C D<br />

MAIN<br />

C C C D<br />

C<br />

MAIN<br />

D D D C C C C C C C<br />

MAIN<br />

TL24440, TM24420<br />

TM18410<br />

TM30412<br />

TM30415, TL30420, TM30240, TL30422<br />

1-32<br />

<strong>BuyLog</strong> <strong>Catalog</strong><br />

www.geindustrial.com Rev. 11/13<br />

Data subject to change<br />

without notice


Load Centers and Circuit Breakers<br />

PowerMark Gold and Plus Load Centers<br />

Circuit Breakers<br />

Wiring Diagrams<br />

Section 1<br />

Breaker Fill<br />

Breaker Symbol 1” THQL 1/2” THQP<br />

1 —<br />

1 2<br />

Wire Range (AWG/kcmil)<br />

Terminal Symbol Cu Al<br />

o 14-8 12-8<br />

• 14-4 12-4<br />

A 6-2 6-2<br />

B 14-1/0 12-1/0<br />

C 6-2/0 6-2/0<br />

D 1-300 2/0-300<br />

E 1-300 1-300<br />

F 6-1 6-1<br />

G 6-3 6-3<br />

MAIN<br />

C C D<br />

MAIN<br />

C C C D<br />

TL42420, TM42415C, TM42420<br />

TL42422<br />

Rev. 11/13<br />

Data subject to change<br />

without notice<br />

www.geindustrial.com <strong>BuyLog</strong> <strong>Catalog</strong> 1-33


Load Centers and Circuit Breakers<br />

PowerMark Gold and Plus Load Centers<br />

Circuit Breakers<br />

Wiring Diagrams<br />

Breaker Fill<br />

Breaker Symbol 1” THQL 1/2” THQP<br />

1 —<br />

1 2<br />

Wire Range (AWG/kcmil)<br />

Section 1<br />

Terminal Symbol Cu Al<br />

o 14-8 12-8<br />

• 14-4 12-4<br />

A 6-2 6-2<br />

B 14-1/0 12-1/0<br />

C 6-2/0 6-2/0<br />

D 1-300 2/0-300<br />

E 1-300 1-300<br />

F 6-1 6-1<br />

G 6-3 6-3<br />

A<br />

C B B C<br />

WHM<br />

MAIN<br />

WHM<br />

A<br />

A<br />

A<br />

TM10RMC, TM12RMC, TM15RMC, TM20RMC,<br />

TSMR015CSGP, TSMR020CSGP<br />

TSL210CSCU, TSL210CFCU<br />

B<br />

WHM<br />

WHM<br />

C<br />

WHM<br />

MAIN<br />

A<br />

A<br />

Load<br />

A<br />

A<br />

A<br />

B<br />

A<br />

A<br />

A<br />

Load<br />

DDC<br />

E<br />

TSL412CSCU<br />

TSL420CSCU, TSL420CFCU<br />

TSM415CSCU, TSM420CSCU, TSMF415CSFL,<br />

TSMF420CSFL, TSMR415CSCUGP, TSMR420CSCUGP,<br />

TSMR415CSFLFMG, TSMR420CSFLFMG<br />

WHM<br />

SPACE PROVIDED<br />

FOR 110A PARALLEL<br />

MAIN BREAKER<br />

MAIN<br />

BREAKER<br />

WHM<br />

MAIN<br />

BREAKER<br />

WHM<br />

MAIN<br />

BREAKER<br />

C<br />

C<br />

C<br />

C<br />

C<br />

C<br />

C<br />

C<br />

TSF420CSCU<br />

TSM1212CSCU, TSM1212CFCU<br />

TSM815CSCU, TSM820CSCU<br />

1-34<br />

<strong>BuyLog</strong> <strong>Catalog</strong><br />

www.geindustrial.com Rev. 11/13<br />

Data subject to change<br />

without notice


Load Centers and Circuit Breakers<br />

PowerMark Gold and Plus Load Centers<br />

Circuit Breakers<br />

Wiring Diagrams<br />

Breaker Fill<br />

Breaker Symbol 1” THQL 1/2” THQP<br />

1 —<br />

1 2<br />

Wire Range (AWG/kcmil)<br />

Section 1<br />

Terminal Symbol Cu Al<br />

o 14-8 12-8<br />

• 14-4 12-4<br />

A 6-2 6-2<br />

B 14-1/0 12-1/0<br />

C 6-2/0 6-2/0<br />

D 1-300 2/0-300<br />

E 1-300 1-300<br />

F 6-1 6-1<br />

G 6-3 6-3<br />

WHM<br />

MAIN<br />

BREAKER<br />

WHM<br />

MAIN<br />

BREAKER<br />

C<br />

C<br />

C<br />

C<br />

TSM1610CSCU, TSM1610CFCU, TSM1612CFCU, TSM1612CSCU<br />

TSM2020CSCU, TSM2020CFCU<br />

D<br />

C<br />

E<br />

C<br />

WHM<br />

WHM<br />

MAIN<br />

BREAKER<br />

C<br />

E<br />

MAIN<br />

D D C<br />

C<br />

MAIN<br />

C<br />

E<br />

A<br />

B<br />

WHM<br />

A<br />

Sub feed lugs<br />

WHM<br />

MAIN<br />

BREAKER<br />

N<br />

TSM2420UF42<br />

TSM815CSFL, TSM820CSFL, TSMF815CSFL,<br />

TSMF820CSFL, TSMR815CSFLFMG,<br />

TSMR820CSFLFMG<br />

TSM3220UWCU<br />

NEUTRAL<br />

A PH<br />

B PH<br />

TSM3220USCU, TSM3220UFCU, TSM3222USCU,<br />

TSM3222UFCU<br />

WHM<br />

MAIN<br />

BREAKER<br />

WHM<br />

C<br />

E<br />

WHM<br />

MAIN<br />

BREAKER<br />

WHM<br />

MAIN<br />

BREAKER<br />

TSM4020UWCU<br />

TSMR1212CSCU, TSMB1212CSCU<br />

TSMR2020CSCU, TSMR2015CSCU,<br />

TSMB2020CSCU, TSMB2015CSCU<br />

TSLR420CSCU, TSLR412CSCU,<br />

TSLB412CSCU, TSLB420CSCU<br />

Rev. 11/13<br />

Data subject to change<br />

without notice<br />

www.geindustrial.com <strong>BuyLog</strong> <strong>Catalog</strong> 1-35


Load Centers and Circuit Breakers<br />

PowerMark Gold and Plus Load Centers<br />

Circuit Breakers<br />

Wiring Diagrams<br />

Breaker Fill<br />

Breaker Symbol 1” THQL 1/2” THQP<br />

1 —<br />

1 2<br />

Wire Range (AWG/kcmil)<br />

Section 1<br />

Terminal Symbol Cu Al<br />

o 14-8 12-8<br />

• 14-4 12-4<br />

A 6-2 6-2<br />

B 14-1/0 12-1/0<br />

C 6-2/0 6-2/0<br />

D 1-300 2/0-300<br />

E 1-300 1-300<br />

F 6-1 6-1<br />

G 6-3 6-3<br />

D<br />

C<br />

Ground<br />

termination<br />

WHM<br />

MAIN<br />

D<br />

D C<br />

WHM<br />

L1 N L2<br />

Space for<br />

Field-installed<br />

TQD Breaker<br />

200A<br />

Main<br />

Breaker<br />

C C<br />

C D<br />

C<br />

E<br />

E<br />

WHM<br />

MAIN<br />

BREAKER<br />

A PH<br />

B PH<br />

TSMR2020CSCUFMG<br />

TM2440RMKS, RMRS, RMS,<br />

TMH2440RMS, TMH2440RMRS<br />

NEUTRAL<br />

TSM2022USCU, TSM2022UFCU<br />

Space for<br />

Field-installed<br />

Breaker<br />

WHM<br />

Line<br />

C<br />

C<br />

L1<br />

N<br />

L2<br />

C<br />

MAIN<br />

E<br />

C<br />

WHM<br />

MAIN<br />

C<br />

E<br />

C<br />

Neutral<br />

TSDA2432UC42, TSDA2440UC42<br />

TSM2015URCU<br />

Space for Field Installed<br />

Second Main Breaker<br />

Space for Field Installed<br />

Second Main Breaker<br />

Space for Field Installed<br />

Second Main Breaker<br />

WHM<br />

WHM<br />

WHM<br />

MAIN<br />

MAIN<br />

MAIN<br />

C<br />

E<br />

TSD032UFCU<br />

TSDR040UFCU<br />

TSDR840UFCU<br />

1-36<br />

T<br />

<strong>BuyLog</strong> <strong>Catalog</strong><br />

www.geindustrial.com Rev. 11/13<br />

Data subject to change<br />

without notice


B<br />

B<br />

B<br />

B<br />

B<br />

D<br />

D<br />

D<br />

D<br />

D<br />

D<br />

D<br />

K<br />

D<br />

K<br />

B<br />

B<br />

B B B<br />

B B B<br />

A<br />

D<br />

D<br />

K<br />

D<br />

D<br />

AA<br />

D<br />

D<br />

D<br />

D<br />

D<br />

B<br />

B<br />

B<br />

B<br />

B<br />

Load Centers and Circuit Breakers<br />

PowerMark Gold and Plus Load Centers<br />

Circuit Breakers<br />

Indoor Enclosures<br />

Section 1<br />

Knockouts<br />

Symbol A • B C D E F G H J K L M N P Q R S T U V W X Y Z<br />

5/16 – – – – – – – – – – – – – – – – – – – – – – – –<br />

– 3/8 – 3/8 – – 3/8 – – – – – – – – – – – – – – – – – –<br />

– 1/2 1/2 1/2 1/2 – 1/2 1/2 1/2 – – – – – – – – – – – – – – – 1/2<br />

– – – 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 – – – 3/4 – – – 3/4 – – 3/4 – 3/4 3/4<br />

Conduit – – – – – – 1 1 1 1 1 1 1 – 1 1 – – 1 – – 1 – 1 1<br />

Size – – – – – – – 1 1/4 1 1/4 1 1/4 1 1/4 1 1/4 1 1/4 1 1/4 – – 1 1/4 1 1/4 – – – 1 1/4 1 1/4 –<br />

in – – – – – – – – – – 1 1/2 1 1/2 1 1/2 1 1/2 – 1 1/2 1 1/2 1 1/2 – – – – 1 1/2 1 1/2 1 1/2<br />

inches – – – – – – – – – – – – 2 2 2 2 2 2 – 2 2 – – 2 2<br />

– – – – – – – – – – – – – – 2 1/2 2 1/2 2 1/2 2 1/2 – 2 1/2 2 1/2 – – 2 1/2 2 1/2<br />

– – – – – – – – – – – – – – – – – 3 – 3 3 – – – –<br />

– – – – – – – – – – – – – – – – – – 3 1/2 3 1/2 3 1/2 – – – –<br />

– – – – – – – – – – – – – – – – – – – – 4 – – – –<br />

Dimensions (in inches)<br />

Box No. Width Height Depth<br />

1A 5 11/16 10 1/4 3 3/8<br />

2 7 1/2 9 7/32 3 5/16<br />

2A 7 1/4 9 3<br />

3A 11 9/16 11 3/8 3 3/8<br />

4 14 19 3 3/4<br />

4A 14 19 3 3/4<br />

6 14 23 3 3/4<br />

7 14 24 11/16 3 3/4<br />

8 14 26 7/16 3 3/4<br />

9 14 28 7/16 3 3/4<br />

9A 14 28 7/16 3 3/4<br />

11 14 33 3/16 3 3/4<br />

12 14 35 7/16 3 3/4<br />

13 14 39 3/16 3 3/4<br />

14 14 43 7/16 3 3/4<br />

15 14 43 7/16 4 5/8<br />

16 16 45 1/8 5 13/16<br />

17 20 59 7/8 6 3/32<br />

18 14 16 3 3/8<br />

H<br />

A<br />

A<br />

H<br />

A<br />

G<br />

G<br />

A<br />

Box 1A<br />

J<br />

D<br />

D<br />

J<br />

H<br />

A<br />

A<br />

H<br />

A<br />

A<br />

B<br />

X<br />

W<br />

D<br />

Box 2<br />

X<br />

D<br />

W<br />

X<br />

A<br />

D<br />

D<br />

X<br />

W<br />

A<br />

G<br />

K<br />

G<br />

A<br />

H<br />

K<br />

D<br />

H<br />

K<br />

D<br />

A<br />

Q<br />

H<br />

A<br />

D<br />

A<br />

H D Y A H<br />

Q M<br />

D D<br />

D F<br />

A<br />

Q<br />

A<br />

A<br />

C<br />

B<br />

C<br />

G<br />

Z<br />

Z<br />

B<br />

K<br />

A<br />

D<br />

D<br />

A<br />

Y<br />

M<br />

H<br />

Y<br />

D<br />

H<br />

Y<br />

B<br />

G<br />

Box 2A<br />

Box 3A<br />

Box 4, 6, 7, 8, 9, 11, 12, 13, 14<br />

Box 4A, 9A<br />

H<br />

S<br />

H<br />

A<br />

B<br />

A<br />

S K<br />

A<br />

C B C S B C<br />

B<br />

B<br />

C<br />

N C<br />

C C<br />

N<br />

B B<br />

K<br />

C K C<br />

Box 15<br />

S<br />

A<br />

B<br />

A<br />

S<br />

A<br />

A<br />

A<br />

B<br />

B<br />

P B J<br />

C<br />

P<br />

C<br />

J<br />

B P<br />

P<br />

T B<br />

Box 16<br />

T<br />

P<br />

A<br />

A<br />

A<br />

B<br />

J G U B V G J<br />

B<br />

C<br />

R<br />

A<br />

P<br />

B<br />

C<br />

B J G J B<br />

Box 17<br />

B<br />

C<br />

B<br />

K<br />

D<br />

K B<br />

B<br />

A<br />

D<br />

Box 18<br />

D<br />

K<br />

AA<br />

B<br />

Rev. 11/13<br />

Data subject to change<br />

without notice<br />

www.geindustrial.com <strong>BuyLog</strong> <strong>Catalog</strong> 1-37


Load Centers and Circuit Breakers<br />

PowerMark Gold and Plus Load Centers<br />

Circuit Breakers<br />

Outdoor Enclosures<br />

Section 1<br />

Knockouts<br />

Symbol A • B C D E F G H J K L M N P Q R S T U V W X Y Z AA BB CC DD<br />

9/16 – – – – – – – – – – – – – – – – – – – – – – – – – – – –<br />

3/8 – 3/8 – – – – – – – – – – – – – – – – – – – – – – – – –<br />

– 1/2 1/2 1/2 1/2 – 1/2 1/2 1/2 – – – – – – – – 1/2 – – – – – – 1/2 – – 1/2 1/2<br />

– – – 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 – – 3/4 – 3/4 – 3/4 – – – 3/4 – – 3/4 – 3/4 3/4 –<br />

Conduit – – – – – – 1 1 1 1 1 1 1 – 1 1 – – 1 – – 1 – 1 – – 1 1 –<br />

Size – – – – – – 1 1/4 – 1 1/4 1 1/4 1 1/4 1 1/4 1 1/4 1 1/4 1 1/4 1 1/4 – 1 1/4 1 1/4 – – – 1 1/4 1 1/4 1 1/4 – 1 1/4 1 1/4 –<br />

in – – – – – – 1 1/2 – – – 1 1/2 1 1/2 1 1/2 1 1/2 – 1 1/2 1 1/2 1 1/2 – – – – 1 1/2 1 1/2 1 1/2 – 1 1/2 1 1/2 1 1/2<br />

Inches – – – – – – – – – – – – 2 2 2 2 2 2 – 2 2 – – 2 2 – 2 2 2<br />

– – – – – – – – – – – – – – 2 1/2 2 1/2 2 1/2 2 1/2 – 2 1/2 2 1/2 – – 2 1/2 – 2 1/2 – – 2 1/2<br />

– – – – – – – – – – – – – – – – – – – 3 3 – – – – 3 – – –<br />

– – – – – – – – – – – – – – – – – – 3 1/2 3 1/2 3 1/2 – – – – 3 1/2 – – –<br />

– – – – – – – – – – – – – – – – – – – – 4 – – – – 4 – – –<br />

Dimensions (in inches)<br />

Box No. Width Height Depth<br />

R1 7 1/2 9 7/32 3 5/16<br />

R1A 7 1/4 10 3 3/4<br />

R1B 7 3/8 13 3 3/4<br />

R2A 11 1/4 11 1/8 3 1/4<br />

R3A 13 21 1/2 5<br />

R3 12 1/2 21 3/16 4 5/8<br />

R4A 14 11/16 30 3/16 5 1/4<br />

R4 14 33 3/16 4 5/8<br />

R5A 13 29 5<br />

R5 12 1/2 28 11/16 4 5/8<br />

R6A 13 33 5<br />

R6 14 35 7/16 4 5/8<br />

R7A 14 11/16 34 3/16 5 1/4<br />

R7 14 39 3/16 4 5/8<br />

R8A 14 21/32 43 1/4 6 13/32<br />

R8 14 43 11/16 5 3/4<br />

R9 16 45 15/16 5 27/32<br />

R10 20 48 15/16 6 7/8<br />

R11 20 59 15/16 6 7/8<br />

R41 7 1/2 13 1/4 4<br />

A<br />

X<br />

W X<br />

B<br />

W<br />

D X<br />

Box R1<br />

D<br />

A<br />

D<br />

X<br />

W<br />

A<br />

G<br />

HUB<br />

B<br />

Box R1A<br />

K<br />

D<br />

D<br />

Box R2A<br />

D<br />

Q<br />

Q<br />

D<br />

D H<br />

A<br />

R<br />

A K D<br />

Q<br />

U<br />

R<br />

U<br />

Q<br />

J<br />

D<br />

B<br />

Box R3A, R5A, R6A<br />

Box R3, R4, R5, R6, R7<br />

Box R8<br />

Box R4A, R7A<br />

R<br />

L<br />

C<br />

L<br />

J<br />

C<br />

C<br />

B<br />

C<br />

Mounting provided<br />

for universal hubs<br />

P<br />

B<br />

B<br />

T<br />

B<br />

J<br />

R<br />

P<br />

B<br />

C<br />

B C C<br />

G V U<br />

C<br />

R<br />

J<br />

K<br />

K<br />

B<br />

B<br />

K<br />

K<br />

K<br />

R8A<br />

Box R9<br />

Box R10, R11<br />

Box R41<br />

1-38<br />

<strong>BuyLog</strong> <strong>Catalog</strong><br />

www.geindustrial.com Rev. 11/13<br />

Data subject to change<br />

without notice


Load Centers and Circuit Breakers<br />

PowerMark Gold and Plus Load Centers<br />

Circuit Breakers<br />

Meter Socket Load Centers<br />

Section 1<br />

Knockouts<br />

Symbol A • B C D E F G H J K L M N P Q R S T U V W X Y Z AA BB CC DD EE FF<br />

5/32 – – – – – – – – – – – – – – – – – – – – – – – – – – – – – –<br />

– 3/8 – 3/8 – – 3/8 – – – – – – – – – – – – – – – – – – – – – – – –<br />

– 1/2 1/2 1/2 1/2 – 1/2 1/2 1/2 – – – – – – – – 1/2 – – – – – – 1/2 – – 1/2 1/2 1/2 –<br />

– – – 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 – – 3/4 – 3/4 – 3/4 – – – 3/4 – 3/4 3/4 – 3/4 3/4 – 3/4 –<br />

Conduit – – – – – – 1 1 1 1 1 1 1 – 1 1 – – 1 – – 1 – 1 – – 1 1 – 1 –<br />

Size – – – – – – 1 1/4 – 1 1/4 1 1/4 1/1/4 1/1/4 1 1/4 1 1/4 1 1/4 1 1/4 – 1 1/4 1 1/4 – – – 1 1/4 1 1/4 1 1/4 – 1 1/4 1 1/4 – 1 1/4 1 1/4<br />

in – – – – – – 1 1/2 – – – 1 1/2 1 1/2 1 1/2 1 1/2 – 1 1/2 1 1/2 1 1/2 – – – – 1 1/2 1 1/2 1 1/2 – 1 1/2 1 1/2 1 1/2 1 1/2 1 1/2<br />

inches – – – – – – – – – – – – 2 2 2 2 2 2 – 2 2 – – 2 2 – 2 2 2 2 2<br />

– – – – – – – – –– – – – – – 2 1/2 2 1/2 2 1/2 2 1/2 – 2 1/2 2 1/2 – – 2 1/2 – 2 1/2 – – 2 1/2 2 1/2 2 1/2<br />

– – – – – – – – – – – – – – – – – – – 3 3 – – – – 3 – – – – –<br />

– – – – – – – – – – – – – – – – – – 3 1/2 3 1/2 3 1/2 – – – – 3 1/2 – – – – –<br />

– – – – – – – – – – – – – – – – – – – – 4 – – – – 4 – – – – –<br />

Dimensions (in inches)<br />

Box No. Width Height Depth<br />

R12 14 23 1/2 4 7/8<br />

R14 14 30 3/4 5 3/4<br />

R15 16 3/4 33 6 3/16<br />

R16 16 3/4 33 6 3/16<br />

R17 16 3/4 34 1/4 7 5/16<br />

R18 14 3/4 33 6 5/16<br />

R19 16 3/4 28 1/2 7 5/16<br />

R20 14 3/4 27 5/16 5 7/16<br />

R21 14 9/16 43 5/8 7 3/16<br />

R22 16 3/16 48 1/8 7 3/16<br />

R23 30 1/4 40 6<br />

R24 30 1/4 40 6<br />

Y<br />

B A<br />

F<br />

B<br />

Semi-Flush Only<br />

F<br />

W<br />

B<br />

Q<br />

A<br />

Semi-Flush Only<br />

K<br />

B<br />

E<br />

HUB<br />

PUNCHING<br />

HUB<br />

PUNCHING<br />

F<br />

F<br />

F<br />

EE<br />

A<br />

B<br />

EE B C B<br />

Box R12<br />

F<br />

A<br />

B C<br />

EE<br />

Box R14<br />

B A<br />

C<br />

BB<br />

B<br />

C C G B B<br />

CC<br />

CC<br />

B B B<br />

C C B B B B<br />

CC<br />

C C<br />

B<br />

C<br />

C<br />

G B B<br />

CC<br />

B B<br />

B B B B<br />

B B B B<br />

B<br />

B<br />

B<br />

B<br />

A<br />

C<br />

B<br />

Box R16<br />

CC C C G B B<br />

CC<br />

B B<br />

C C BBBB<br />

B<br />

C<br />

BB<br />

B BB<br />

C<br />

B<br />

B<br />

B B B<br />

B B<br />

C<br />

B B<br />

C<br />

B<br />

B<br />

A<br />

Box R17, R18<br />

K<br />

Q<br />

CC<br />

B<br />

C C<br />

B G<br />

C<br />

B<br />

C<br />

B<br />

B<br />

Box R19, R20<br />

A<br />

CC<br />

S<br />

Z<br />

S<br />

Z<br />

Z<br />

B<br />

D<br />

R<br />

S<br />

K<br />

R<br />

S<br />

K<br />

B<br />

C<br />

AA<br />

G<br />

R<br />

D<br />

K<br />

AA<br />

G<br />

R<br />

D<br />

B<br />

K<br />

D<br />

D<br />

Box R21, R22<br />

Box R23<br />

Box R24<br />

Rev. 11/13<br />

Data subject to change<br />

without notice<br />

www.geindustrial.com <strong>BuyLog</strong> <strong>Catalog</strong> 1-39


Load Centers and Circuit Breakers<br />

PowerMark Gold and Plus Load Centers<br />

Circuit Breakers<br />

Meter Socket Load Centers<br />

Section 1<br />

Knockouts<br />

Symbol A • B C D E F G H J K L M N P Q R S T U V W X Y Z AA BB CC DD EE FF<br />

5/32 – – – – – – – – – – – – – – – – – – – – – – – – – – – – – –<br />

– 3/8 – 3/8 – – 3/8 – – – – – – – – – – – – – – – – – – – – – – – –<br />

– 1/2 1/2 1/2 1/2 – 1/2 1/2 1/2 – – – – – – – – 1/2 – – – – – – 1/2 – – 1/2 1/2 1/2 –<br />

– – – 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 – – 3/4 – 3/4 – 3/4 – – – 3/4 – 3/4 3/4 – 3/4 3/4 – 3/4 –<br />

Conduit – – – – – – 1 1 1 1 1 1 1 – 1 1 – – 1 – – 1 – 1 – – 1 1 – 1 –<br />

Size – – – – – – 1 1/4 – 1 1/4 1 1/4 1/1/4 1/1/4 1 1/4 1 1/4 1 1/4 1 1/4 – 1 1/4 1 1/4 – – – 1 1/4 1 1/4 1 1/4 – 1 1/4 1 1/4 – 1 1/4 1 1/4<br />

in – – – – – – 1 1/2 – – – 1 1/2 1 1/2 1 1/2 1 1/2 – 1 1/2 1 1/2 1 1/2 – – – – 1 1/2 1 1/2 1 1/2 – 1 1/2 1 1/2 1 1/2 1 1/2 1 1/2<br />

inches – – – – – – – – – – – – 2 2 2 2 2 2 – 2 2 – – 2 2 – 2 2 2 2 2<br />

– – – – – – – – –– – – – – – 2 1/2 2 1/2 2 1/2 2 1/2 – 2 1/2 2 1/2 – – 2 1/2 – 2 1/2 – – 2 1/2 2 1/2 2 1/2<br />

– – – – – – – – – – – – – – – – – – – 3 3 – – – – 3 – – – – –<br />

– – – – – – – – – – – – – – – – – – 3 1/2 3 1/2 3 1/2 – – – – 3 1/2 – – – – –<br />

– – – – – – – – – – – – – – – – – – – – 4 – – – – 4 – – – – –<br />

Dimensions (in inches)<br />

HUB<br />

PUNCHING<br />

HUB<br />

PUNCHING<br />

HUB<br />

PUNCHING<br />

HUB<br />

PUNCHING<br />

Box No. Width Height Depth<br />

R25 14 26 4 1/2<br />

R26 14 9/16 43 5/8 6 3/16<br />

R27 14 9/16 48 1/8 6 3/16<br />

R28 22 1/2 27 7/8 6 1/4<br />

R29 22 1/2 34 7/8 6 1/4<br />

R30 14 9/16 40 1/2 6 3/16<br />

R31 14 9/16 33 9/16 6 3/16<br />

R32 16 17 5<br />

R32A 18 7/8 18 9/16 5<br />

R40 14 32 4 1/2<br />

Z<br />

Z<br />

Z<br />

S<br />

Z<br />

1/4"<br />

B B B<br />

B B<br />

B B B B<br />

B B<br />

C<br />

K<br />

S<br />

S<br />

B<br />

Box R25<br />

Box R26, R27<br />

d<br />

B<br />

EE<br />

EE<br />

BB<br />

B<br />

BB<br />

BB<br />

BB<br />

R<br />

L<br />

B<br />

B A B C<br />

G<br />

B<br />

C<br />

B B<br />

BB<br />

B<br />

C<br />

G<br />

B<br />

C<br />

B B<br />

BB<br />

B<br />

C<br />

B<br />

B<br />

C<br />

B<br />

B<br />

Box R28<br />

Box R29<br />

Box R30<br />

HUB<br />

PUNCHING<br />

HUB<br />

PUNCHING<br />

A<br />

B<br />

R<br />

L<br />

C<br />

B<br />

B C<br />

Box R31<br />

HUB<br />

FF<br />

G G<br />

P<br />

A B B<br />

Box R32<br />

FF<br />

FF<br />

A B<br />

B<br />

Box R32A<br />

P<br />

FF<br />

9/32<br />

CC CC CC<br />

GG<br />

EE<br />

E<br />

EE<br />

Box R40<br />

1-40<br />

<strong>BuyLog</strong> <strong>Catalog</strong><br />

www.geindustrial.com Rev. 11/13<br />

Data subject to change<br />

without notice


Load Centers and Circuit Breakers<br />

PowerMark Gold and Plus Load Centers<br />

Circuit Breakers<br />

Meter Socket Load Centers<br />

Section 1<br />

Knockouts<br />

Symbol A • B C D E F G H J K L M N P Q R S T U V W X Y Z AA BB CC DD EE FF GG<br />

5/32 – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – –<br />

– 3/8 – 3/8 – – 3/8 – – – – – – – – – – – – – – – – – – – – – – – – –<br />

– 1/2 1/2 1/2 1/2 – 1/2 1/2 1/2 – – – – – – – – 1/2 – – – – – – 1/2 – – 1/2 1/2 1/2 – –<br />

– – – 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 – – 3/4 – 3/4 – 3/4 – – – 3/4 – 3/4 3/4 – 3/4 3/4 – 3/4 – –<br />

Conduit – – – – – – 1 1 1 1 1 1 1 – 1 1 – – 1 – – 1 – 1 – – 1 1 – 1 – –<br />

Size – – – – – – 1 1/4 – 1 1/4 1 1/4 1/1/4 1/1/4 1 1/4 1 1/4 1 1/4 1 1/4 – 1 1/4 1 1/4 – – – 1 1/4 1 1/4 1 1/4 – 1 1/4 1 1/4 – 1 1/4 1 1/4 1 1/4<br />

in – – – – – – 1 1/2 – – – 1 1/2 1 1/2 1 1/2 1 1/2 – 1 1/2 1 1/2 1 1/2 – – – – 1 1/2 1 1/2 1 1/2 – 1 1/2 1 1/2 1 1/2 1 1/2 1 1/2 1 1/2<br />

inches – – – – – – – – – – – – 2 2 2 2 2 2 – 2 2 – – 2 2 – 2 2 2 2 2 2<br />

– – – – – – – – –– – – – – – 2 1/2 2 1/2 2 1/2 2 1/2 – 2 1/2 2 1/2 – – 2 1/2 – 2 1/2 – – 2 1/2 2 1/2 2 1/2 2 1/2<br />

– – – – – – – – – – – – – – – – – – – 3 3 – – – – 3 – – – – – 3<br />

– – – – – – – – – – – – – – – – – – 3 1/2 3 1/2 3 1/2 – – – – 3 1/2 – – – – – –<br />

– – – – – – – – – – – – – – – – – – – – 4 – – – – 4 – – – – – –<br />

Dimensions (in inches)<br />

Box No. Width Height Depth<br />

R33 30 1/4 33 6 3/32<br />

R34 30 1/4 40 6 3/32<br />

R35 30 1/4 47 6 3/32<br />

R36 14 28 1/2 4 1/2<br />

R37 14 31 3/4 4 1/2<br />

R38 14 49 1/2 10<br />

R39 14 31 11/16 4 5/8<br />

R40 14 32 4 1/2<br />

AA<br />

AA<br />

3/32<br />

D<br />

S S Z S<br />

3/32<br />

3/32<br />

K K K<br />

R<br />

R<br />

D G D<br />

D D D D D D D D<br />

D<br />

S S Z S<br />

3/32<br />

3/32<br />

K K K<br />

R<br />

R<br />

D G D<br />

D D D D D D D D<br />

Box R33<br />

Box R34, R35<br />

HUB<br />

HUB<br />

HUB<br />

HUB<br />

9/32<br />

CC CC CC<br />

9/32<br />

CC CC CC<br />

GG EE E<br />

G G<br />

GG<br />

EE EE<br />

E<br />

L<br />

D B D B D<br />

B B<br />

W D D D D D<br />

L<br />

Box R36A, R37A<br />

Box R36B, R37B<br />

Box R38<br />

HUB<br />

EE<br />

EE<br />

EE<br />

9/32<br />

C<br />

C<br />

C<br />

C<br />

C<br />

C<br />

EE<br />

9/32<br />

CC CC CC<br />

C<br />

C<br />

C<br />

EE<br />

d<br />

C<br />

C<br />

C C C<br />

C C<br />

C<br />

K<br />

C<br />

GG<br />

EE<br />

E<br />

EE<br />

Box R39<br />

Box R40<br />

Rev. 11/13<br />

Data subject to change<br />

without notice<br />

www.geindustrial.com <strong>BuyLog</strong> <strong>Catalog</strong> 1-41


Load Centers and Circuit Breakers Section 1<br />

NOTES:<br />

1-42<br />

<strong>BuyLog</strong> <strong>Catalog</strong><br />

www.geindustrial.com Rev. 11/13<br />

Data subject to change<br />

without notice