10.06.2016 Views

eldo_user

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Eldo Premier<br />

Miscellaneous Limitations of Devices and Features in Eldo Premier<br />

Eldo Premier Output<br />

Netlist Support<br />

Miscellaneous Limitations of Devices and Features<br />

in Eldo Premier<br />

The following devices and features are not supported by the Eldo Premier kernel:<br />

• Magnetic and Switched Capacitor Eldo macromodels (except for the Sxx switch).<br />

• IBIS models.<br />

• Controlled devices using a function of frequency or time.<br />

• Eldo Interactive mode.<br />

• Merckel MOSFET models.<br />

• Specifying a temperature expression as a parameter of the .TEMP command<br />

(.TEMP ) produces incorrect simulation results for devices whose values<br />

vary with temperature (expression depends on the TEMPER variable).<br />

Workaround: Always use a numerical value instead of an expression as a parameter of<br />

the .TEMP command.<br />

When a model is not supported by Eldo Premier, a warning 93 is displayed causing an<br />

automatic switch to Eldo Classic. For example:<br />

Warning 93: Premier has been deactivated due to the unsupported model of<br />

the object 'M1' (MERCK1).<br />

Related Topics<br />

Overview of Eldo Premier<br />

Enabling Eldo Premier<br />

Eldo Premier Output<br />

Netlist Support<br />

Eldo® User's Manual, 15.3 93