IBIS Models Support in Eldo<br />

IBIS Component<br />

Keep the scaling factors as calculated.<br />

YES<br />

Limit the switching scaling factors between 0 and 1.<br />

Switching scaling factors are extracted from the rising/falling waveforms, and used to<br />

modulate the output current of the buffer while switching.<br />

o<br />

o<br />

Scaling factor 0 indicates fully off for the working network.<br />

Scaling factor 1 indicates fully on.<br />

Sometimes these factor values exceed one or become negative, causing a negative slope,<br />

that may lead to some convergence problems.<br />

Note<br />

The POWER setting helps to avoid non-convergence issues whilst keeping the<br />

correct buffer behavior on the a_signal terminal.<br />

• corner=TYP|MIN|MAX|FAST|SLOW<br />

Specifies the IBIS corner to be used to extract the data from the IBIS file. The default is<br />

corner=TYP—if any data is missing under the Min or Max columns in the IBIS file then<br />

the Typ column value will be used instead. When corner=TYP, MIN, or MAX, simulation<br />

will extract the data under the corresponding Typ, Min, and Max columns in the IBIS file.<br />

When corner=FAST or SLOW, corner uses combinations from data under the Min and<br />

Max columns; FAST is the same as MAX, and SLOW is the same as MIN except for<br />

parameters listed in Table 17-5.<br />

• warn=ON|OFF<br />

Specifies if the warning message generated for this instance should be printed (ON), or<br />

suppressed (OFF). Setting warn=OFF is equivalent to using the keyword nowarn. The<br />

default setting is ON.<br />

• nowarn<br />

This is equivalent to warn=OFF.<br />

• msel_mode=value<br />

The value indicates a model order under the [Model Selector] keyword in the IBIS file. If<br />

the value specified is greater than the model selector list, then the first model will be<br />

selected. The default is 1.<br />

• model_selector='mod_sel1=mod_name1 [, mod_sel2=mod_name2 ,...]'<br />

This keyword can be repeated more than once. model_selector is used to select models for<br />

some or all model selectors in the given IBIS file. model_selector has a higher precedence<br />

over msel_mode.<br />

• package=0|1|2|3|4|OFF|CMPNT|PIN|PKGMOD|MIX<br />

This keyword specifies the package modeling type to be used for package parasitics.<br />