Working with S, Y, Z Parameters<br />

CITIfile Data File Format<br />

CITIfile Data File Format<br />

Input for: Eldo and Eldo RF<br />

CITIfile stands for Common Instrumentation Transfer and Interchange file format. Eldo<br />

partially supports CITIfile versions A.01.00 and A.01.01 formats for reading only. When<br />

reading, the format is automatically detected.<br />

Format<br />

The CITIfile data format file is an ASCII text file in which data appears line by line: N lines for<br />

each data point of N ports. The data points are stored in increasing order of frequency.<br />

Tip<br />

CITIfile data format files follow general syntax rules. The standard is available from the<br />

Agilent website:<br />

http://edadocs.software.keysight.com/display/ads2009U1/<br />

Working+with+Data+Files#WorkingwithDataFiles-CITIfileDataFormat<br />

• A typical CITIfile package is divided into two parts:<br />

o<br />

o<br />

The header is made up of keywords and setup information.<br />

The data usually consists of one or more arrays of data.<br />

• The length of a line within a CITIfile package should not exceed 80 characters. This<br />

allows instruments which may have limited RAM to define a reasonable input buffer<br />

length.<br />

• Keywords are always at the beginning of a new line. The end of a line is as defined by<br />

the file system or transfer mechanism being used.<br />

• Arrays of data start after the BEGIN keyword, and the END keyword follows the last<br />

data element in an array.<br />

Parameters<br />

Keyword<br />

CITIFILE<br />

NAME<br />

VAR<br />

CONSTANT<br />

Table 14-2. CITIfile Data Format Supported Keywords<br />

Limitations / Requirements<br />

Only A.01.00 and A.01.01 revisions are supported.<br />

Keywords after NAME are ignored.<br />

Only FREQ and MAG keywords supported.<br />

VAR FREQ MAG is mandatory.<br />

Supported:<br />

NBR_OF_PORTS (mandatory).<br />

NORMALIZATION (optional, only the value “1” is supported).<br />