10.06.2016 Views

eldo_user

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Working with S, Y, Z Parameters<br />

Touchstone Data File Format<br />

Touchstone Data File Format<br />

Input or output for: Eldo and Eldo RF; output generated by the .FFILE command<br />

Eldo fully supports Touchstone® versions v1 and v2 formats for reading and writing. When<br />

reading, the format is automatically detected.<br />

Note<br />

See the .FFILE command in the Eldo Reference Manual.<br />

Format<br />

The Touchstone data format file is an ASCII text file in which data appears line by line: N lines<br />

for each data point of N ports. The data points are stored in increasing order of frequency.<br />

The first of the N lines consist of a frequency value and N pairs of values for S, Y, Z, G, H, T or<br />

A parameters. The (N-1) following lines contain N pairs of values. Values are separated by one<br />

or more spaces or tabulations.<br />

Tip<br />

Touchstone data format files follow general syntax rules. The standard is available from the<br />

EDA Industry Working Groups website:<br />

Touchstone version 1:<br />

http://www.eda.org/pub/ibis/connector/touchstone_spec11.pdf<br />

Touchstone version 2:<br />

http://www.eda.org/pub/ibis/touchstone_ver2.0/touchstone_ver2_0.pdf<br />

• Comment lines begin with an exclamation mark (!).<br />

• The first uncommented line in the Touchstone data file must be an option specification<br />

line that begins with the pound sign (#) followed by a space. The option line is formatted<br />

as follows:<br />

# [Hz|kHz|MHz|GHz] [S|Y|Z|G|H|T|A] [RI|MA|DB] [R Val|R1 Val1 ... Rn<br />

Valn]<br />

Parameters<br />

• [Hz|kHz|MHz|GHz]<br />

Frequency Unit (Hz, kHz, MHz, GHz). Default value is Hz.<br />

• [S|Y|Z|G|H|T|A]<br />

Parameter type (S, Y, Z, G, H, T, A). Default value is S.<br />

• [RI|MA|DB]<br />

Data format (MA, DB, RI). Default value is RI. MA means Magnitude-angle in Volts, and<br />

phase in degrees. DB means Magnitude in dB, and phase in degrees. RI means Real and<br />

Imaginary parts.<br />

Eldo® User's Manual, 15.3 705

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!