Working with S, Y, Z Parameters<br />

Instantiating a Block Defined by S, Y, Z Parameters<br />

"Warning 1824: OBJECT "YNPORT0": Input data non-passive:<br />

overshoot 1.018228e+00 at freq = 2.254981e+07"<br />

o<br />

pre-fit passivity enforcement:<br />

"Warning 1822: OBJECT "YNPORT0": Enforcing passivity of input<br />

data."<br />

o<br />

post-fit passivity enforcement:<br />

"Warning 1823: OBJECT "YNPORT0": Enforcing post-fit global<br />

passivity."<br />

If non-reciprocal linear active devices (such as amplifiers or filters) are to be simulated, both<br />

SYMMETRY and FORCE_PASSIVITY should be disabled.<br />

• FORCE_REFIT=val<br />

Set to 1 to force fitting in CPF regardless as to whether the corresponding .pls file is already<br />

present or not. This might be needed if you want to redo fitting with different options, such<br />

as FORCE_PASSIVITY. However, you should be careful in using such an option, it should<br />

be disabled after the desired fit is built. The default value is 0, disabled.<br />

• EXTRAP_TO_DC=val<br />

Set to 1 to restore a missing point at zero frequency (DC) by extrapolating the curve from<br />

low frequency points given in the Touchstone file. Compared to the default case<br />

(EXTRAP_TO_DC=0) it enables, as a rule, to achieve better accuracy in DC simulation<br />

when the point at zero frequency is not given. If the DC point is present in the input data,<br />

this option has no effect unless incorrect DC data has been detected in the S parameter .par<br />

or .snp file; in which case EXTRAP_TO_DC is automatically enabled and a warning<br />

generated; see the FORCE_TOUCH_DC description.<br />

• FORCE_TOUCH_DC=val<br />

Set to 1 to force DC data to be used from the S parameter .par or .snp file. The default value<br />

is 0, disabled. If incorrect DC data has been detected in the S parameter file a warning is<br />

generated:<br />

+ In , DC value seems to be incoherent.<br />

+ It is ignored and its value is extrapolated (EXTRAP_TO_DC set to<br />

1).<br />

+ To force its use, set the parameter FORCE_TOUCH_DC to 1 in the<br />

+ corresponding FBLOCK.<br />

The DC value is ignored and EXTRAP_TO_DC is automatically enabled for the<br />

corresponding FBLOCK. If, despite this recommendation, you choose to force the incorrect<br />

DC data to be used (FORCE_TOUCH_DC=1) this value can lead to incorrect results.<br />

• POLE_REDUCTION=val<br />

Default value is 1. Enables the mode of transient simulation in which some of the fitted<br />

poles (that are too fast, too slow or too small) are removed to speed-up the solution. This<br />

mode typically gives up to 30-50% reduction in solution time when the step of the transient<br />

Eldo® User's Manual, 15.3 701