SPEF File Example for Corners<br />

Post-Layout Simulation<br />

SPEF File Example for Corners<br />

This example shows how Eldo handles this SPEF file depending on the corner parameters<br />

specified.<br />

SPEF file:<br />

*SPEF "IEEE 1481-1997"<br />

*DESIGN "TEST"<br />

*DATE "Wed Jun 18 11:28:40 2008"<br />

*VENDOR "Mentor Graphics"<br />

*DESIGN_FLOW ""<br />

*DIVIDER /<br />

*DELIMITER :<br />

*BUS_DELIMITER [ ]<br />

*T_UNIT 1 NS<br />

*C_UNIT 1 PF<br />

*R_UNIT 1 KOHM<br />

*L_UNIT 1 HENRY<br />

*PORTS<br />

N0 O<br />

top O<br />

*D_NET N1 0.0000:0.01:0.2<br />

*CAP<br />

1 N1 N0 1.1:2.3:5.2<br />

*RES<br />

1 N1 top 1<br />

*END<br />

The Eldo handling of this SPEF file depends on the .SPEF_INCLUDE corner parameter<br />

specified. If you have:<br />

.SPEF_INCLUDE FILE=test.spef CORNER=1<br />

In this example, with CORNER=1, Eldo takes *D_NET N1 0.0000 and 1 N1 N0 1.1.<br />

.SPEF_INCLUDE FILE=test.spef CORNER=2<br />

In this example, with CORNER=2, Eldo takes *D_NET N1 0.01 and 1 N1 2.3.<br />

.SPEF_INCLUDE FILE=test.spef CORNER=3<br />

In this example, with CORNER=3, Eldo takes *D_NET N1 0.2 and 1 N1 N0 5.2.<br />

(min:typ:max) can be used as an alternative to select one of the three values. By default, Eldo<br />

takes the second value if there are three values specified.<br />