Analyzing Simulation Results<br />

Output Files Generated<br />

File Extension<br />

.pz<br />

.stat<br />

.dex<br />

.otm<br />

.ops<br />

.op<br />

.opX<br />

.probeop<br />

.mapop<br />

.files_dump<br />

.iic<br />

.sav<br />

.sfo, .yfo, .hfo,<br />

.nfo, .gfo, .tfo, .afo, .zfo<br />

.nactivity<br />

.activity<br />

.trX<br />

.acX<br />

.swX<br />

.mtX<br />

.ftX<br />

Table 9-1. Eldo Standard Output Files (cont.)<br />

Description<br />

Output file used by the Pole Zero post-processor. Created when a<br />

.PZ command is specified in the netlist file.<br />

See “Pole Zero Analysis” on page 230.<br />

You can view .pzr files (generated from .pz files) with the AMS<br />

Results Browser.<br />

Created when Eldo is invoked with the -stat argument. This file<br />

should be sent to a support engineer in the event of a problem.<br />

See “Statistics File” on page 57.<br />

Design of experiments output file. Created when a .DEX<br />

command is specified in the netlist file.<br />

See “Statistical Experimental Design and Analysis” on page 555.<br />

Optimizer output file. Created when a .OPTIMIZE command is<br />

specified in the netlist file.<br />

See “Optimization” on page 587.<br />

Operating point information output files. Created when a .OP<br />

command is specified in the netlist file.<br />

See the .OP command and .OPTION PROBEOP in the Eldo<br />

Reference Manual.<br />

File containing all the files opened by Eldo (except temporary<br />

files) for a simulation. Useful for packaging an Eldo testcase.<br />

See .OPTION DUMP_FILE_LIST in the Eldo Reference<br />

Manual.<br />

Saved simulation information to be reused for additional<br />

simulations.<br />

See the .SAVE command option in the Eldo Reference Manual.<br />

S, Y, Z parameter output file specified with the .FFILE<br />

command.<br />

See “Working with S, Y, Z Parameters” on page 683.<br />

Circuit activity check. List of inactive (or active) nodes inside a<br />

design.<br />

See the .ACTIVITY command option in the Eldo Reference<br />

Manual.<br />

Generated with option COMPAT or -compat.<br />

HSPICE output files created during simulation in the netlist<br />

control file directory.<br />

See “HSPICE Compatibility” on page 162.<br />

360<br />