Safe Operating Area (SOA) Checks<br />

Specifying Simulation Output<br />

Safe Operating Area (SOA) Checks<br />

You can detect when a component is used outside safe operating area (SOA) limits. The SOA<br />

can also be used to verify min-max measurements. A warning will be generated during the<br />

simulation and displayed to the standard output and inside the .chi file. You can specify a<br />

separate file to write SOA results to. They can also be plotted for display in EZwave.<br />

Tip<br />

You can view safe operating area violations with the AMS Results Browser.<br />

Two commands are available for use with specifying and checking the safe operating area:<br />

• .SETSOA<br />

Specifies the safe operating area limits for devices, model parameters, or expressions.<br />

This can be defined in the netlist or any device library.<br />

See “.SETSOA” in the Eldo Reference Manual.<br />

• .CHECKSOA<br />

Checks the safe operating area limits previously set using .SETSOA.<br />

See “.CHECKSOA” in the Eldo Reference Manual.<br />

Plotting Safe Operating Area Limits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 341<br />

Safe Operating Area Examples . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 345<br />

Plotting Safe Operating Area Limits<br />

Use the output quantity SOA(identifier) for .PLOT and .PROBE commands. This quantity only<br />

applies to .wdb (EZwave) output because it creates an assertion bus type object. The following<br />

syntaxes can be specified to create assertion buses:<br />

• Generic command:<br />

.probe [analysis] SOA<br />

This will probe all .SETSOA commands in a design.<br />

• SOA output quantity for subcircuit instance:<br />

.probe|.plot SOA(xinst)<br />

This will probe/plot all .SETSOA commands inside subcircuit instance named xinst.<br />

• SOA output quantity for device:<br />

.probe|.plot SOA(device)<br />

Eldo® User's Manual, 15.3 341