10.06.2016 Views

eldo_user

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Setting Up An Analysis<br />

Transient Noise Analysis<br />

For .NOISETRAN, the default HMAX value is HMAX=1/(2×FMAX). It is better to explicitly<br />

set a lower value for HMAX than a high value for FMAX to achieve the best accuracy possible.<br />

Related Commands<br />

• .NOISETRAN command in Eldo Reference Manual<br />

• .OPTION NOISETRAN_TUNING in Eldo Reference Manual<br />

Related Topics<br />

Specifying .NOISETRAN Parameters<br />

Transient Noise Analysis Results<br />

Transient Noise Analysis Results<br />

The results of transient noise analysis runs are output using .EXTRACT, .PLOT, .PRINT, and<br />

.PROBE commands. Eldo prints in ASCII form the individual contributions of the noisy devices<br />

in the .chi file.<br />

If extracts have been specified, the results are provided inside the NOISETRAN EXTRACT<br />

INFORMATION section of the .chi file.<br />

Figure 6-14 shows example transient noise analysis results with and without noise:<br />

Figure 6-17. Transient Noise Analysis Plot<br />

Eldo® User's Manual, 15.3 259

Hooray! Your file is uploaded and ready to be published.