Simulator Compatibility<br />

Options in Compat Mode<br />

.TRAN INCR1 T1 [{INCRn Tn}] [TSTART=val] [UIC]<br />

See the “.TRAN command” in the Eldo Reference Manual.<br />

Related Topics<br />

HSPICE Compatibility<br />

Options in Compat Mode<br />

Some options have different behavior in HSPICE compatibility mode.<br />

• ACDERFUNC<br />

This option is automatically unset in compat mode.<br />

• ACM<br />

This option is automatically set in compat mode.<br />

• ACOUT=VAL<br />

ACOUT defaults to 1.<br />

1 — Vx(a,b) or Ix(a,b) are computed from the complex value Vx(a,0)-Vx(b,0) or from<br />

Ix(a,0)-Ix(b,0).<br />

• DEFPTNOM<br />

This option is automatically set in compat mode. Enables a parameter to be defined with<br />

the name TNOM. In such a case, this value will be used inside parameter expressions,<br />

instead of the default TNOM or the value set using option TNOM=val.<br />

• ICDC and ICDEV<br />

These options are automatically set in compat mode. This means that IC specifications<br />

given on devices are taken into account for the DC which is performed prior to TRAN.<br />

When -compat is not set, and neither are the ICDC and ICDEV options, then IC<br />

specifications given on devices are ignored, unless the UIC keyword is specified on the<br />

.TRAN card.<br />

• GENK<br />

This option is automatically set in compat mode. It forces Eldo to generate second order<br />

mutual inductors. It is used together with the KLIM option.<br />

• (NO)KWSCALE<br />

This option is automatically set in compat mode. Therefore, SCALE is not treated as a<br />

keyword and can be used as a parameter.<br />

• LIBINC<br />