Simulator Compatibility<br />

Commands in Compat Mode<br />

devices, I2 returns the same value as I1.For M/B/J devices, I3 is positive when current<br />

leaves the object by pin number 3.<br />

See the “.PLOT” and “.PRINT” commands in the Eldo Reference Manual.<br />

• .PROBE<br />

The Eldo .PROBE command is emulated; all node voltages are dumped in the binary<br />

output file (.wdb). To only dump those items specified in .PLOT/.PROBE in the output<br />

file, add .OPTION PROBE.<br />

When .PROBE I is specified with .OPTION POST, only currents through dipoles are<br />

plotted, MOS current pins are not.<br />

See the “.PROBE command” in the Eldo Reference Manual.<br />

• .SAVE<br />

In compat mode, generates a .ic0 file.<br />

See the “.SAVE command” in the Eldo Reference Manual.<br />

• .SUBCKT<br />

When GLOBAL node names are used in the .SUBCKT definition node list, Eldo will<br />

check the node names in the subcircuit list definition prior to the global node list.<br />

See the “.SUBCKT command” in the Eldo Reference Manual.<br />

• .TEMP<br />

The model parameter TREF can be specified. This is equivalent to the parameter TNOM<br />

when the .TEMP command is used to apply temperature effects. When TREF is<br />

specified, TNOM will be ignored.<br />

o<br />

.PARAM TEMP<br />

In compat mode, you must use the TEMPER variable to return the current<br />

simulation temperature set by the .TEMP command. The TEMP variable is not<br />

supported in compat mode.<br />

See the “.TEMP command” in the Eldo Reference Manual.<br />

• .TRAN<br />

If the .TRAN command has four parameters, for example:<br />

.TRAN tprint tstop tstart hmax<br />

o<br />

If value4 (hmax) < value2 (tstop), it is handled as in Eldo standard mode:<br />

.TRAN tprint tstop tstart hmax<br />

o<br />

If value4 (hmax) ≥ value2 (tstop), it is handled as a list of INCRn Tn values:<br />

Eldo® User's Manual, 15.3 171