10.06.2016 Views

eldo_user

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Warning<br />

Number<br />

Table A-16. Miscellaneous Warnings (cont.)<br />

Description<br />

Error and Warning Messages<br />

Miscellaneous Warnings<br />

Warning 1433 COMMAND "%s": This command is interpreted as .PROBE<br />

Warning 1434 COMMAND "%s": Analysis disabled. MODEL %s is crypted. Accessing its<br />

parameters is not possible unless:<br />

1/ command .SETKEY is crypted with the .MODEL<br />

2/ command .USEKEY must be given in the netlist using the encrypted<br />

models<br />

Warning 1435 New definition of .FOUR %s ignored<br />

Warning 1436 COMMAND ".USE_VERILOG": This command has been deprecated inside<br />

Questa ADMS. ai file is ignored and the work library loaded instead<br />

Warning 1437 COMMAND "%s": Quantity %s has been replaced by %s<br />

Warning 1438 COMMAND .EXTRACT/.MEAS %s: Unable to find measurement %s.<br />

Command ignored<br />

Warning 1439 Parameter %s found in %s %s depends directly or undirectly on DEV<br />

specification. This is not supported yet by Questa ADMS<br />

Warning 1440 .OPTION %s: unknown specification %s ignored<br />

Warning 1441 .OPTION %s is ignored. It is only active when PSF_VERSION=2<br />

Warning 1442 COMMAND "%s": The type of analysis must be specified when RF analysis<br />

are used. Command ignored<br />

Warning 1443 COMMAND "%s": Unable to code %s in base %ld<br />

Warning 1444 COMMAND "%s": labeled "%s". The expression "%s" contains a SNF card<br />

that was not found<br />

Warning 1445 COMMAND .OPTIMIZE: OUTER specification is ignored since the netlist<br />

contains no .STEP commands<br />

Warning 1446 COMMAND .EXTRACT/.MEAS %s: Fitting waveforms requires to have<br />

either .option OUT_STEP, TIMESMP or FREQSMP. Fitting command<br />

ignored<br />

Warning 1447 Unable to release %s license, feature "%s"<br />

Warning 1448 COMMAND "%s": No .extract or .meas labeled %s was found. This<br />

command is ignored<br />

Warning 1449 COMMAND .FILTER: keyword %s has already been defined. First value is<br />

kept<br />

Warning 1450 OBJECT "%s": W/L parameters specified, a model should have been<br />

assigned to this device. As a value has been set, these parameters are ignored<br />

for computation of the effective resistor value<br />

Eldo® User's Manual, 15.3 1441

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!