Error and Warning Messages<br />

Miscellaneous Warnings<br />

Warning<br />

Number<br />

Warning 1037<br />

Warning 1038<br />

Warning 1039<br />

Warning 1040<br />

Warning 1041<br />

Warning 1042<br />

Warning 1043<br />

Warning 1044<br />

Warning 1045<br />

Warning 1046<br />

Warning 1047<br />

Warning 1048<br />

Warning 1049<br />

Warning 1050<br />

Warning 1051<br />

Warning 1052<br />

Warning 1053<br />

Warning 1054<br />

Warning 1055<br />

Table A-16. Miscellaneous Warnings (cont.)<br />

Description<br />

Standard Eldo Mach commands ignored in Eldo Mach Black-Box mode<br />

Command .EXTRACT OPMODE on name: name is not a valid keyword.<br />

COMMAND .STEP: keyword (AUTOINCR) is ignored. It can only be<br />

applied on .STEP PARAM syntax.<br />

COMMAND .MC: keyword OUTER is disabled. No multi-run analysis has<br />

been specified.<br />

COMMAND .PRINT or .PLOT SSTJITTER: Expected SSTJITTER output,<br />

and not name<br />

COMMAND .PRINT or .PLOT SSTSTABIL: Expected SSTSTABIL output,<br />

and not name<br />

COMMAND .PRINT or .PLOT: output name will be written as real/<br />

imaginary parts in files which do not support complex format.<br />

COMMAND .EXTRACT or .MEAS: Unexpected name output<br />

COMMAND .PRINTFILE: Element name not declared<br />

COMMAND .DSPF_INCLUDE: file name. An extra X has been added on<br />

name. That rule of adding an extra X will now be used by default in that file<br />

for all subsequent *|NET instructions.<br />

BUS name is of size 0: Could be declaration of that bus is missing.<br />

.OPTION name: list of values are limited to 10 elements.<br />

COMMAND .OPTWIND name is incompatible with options defined as a list<br />

of values. Only first value is kept.<br />

COMMAND name:Node name not found<br />

COMMAND name:Device name not found<br />

Object name: Eldo will simulate as if CTYPE = 1 had been set on that<br />

instance... This is because C value seems not to be dependant on the pin bias,<br />

or pins are connected to power supply or ground, and in such situations,<br />

CTYPE = 1 mode is usually more appropriate.. However, in case this tuning<br />

is here not appropriate, just set CTYPE = 0 on the device, or use .OPTION<br />

NOAUTOCTYPE in order to disable this setup.<br />

COMMAND .EXTRACT: name is ignored.<br />

COMMAND .FOUR: name removed<br />

COMMAND .MC: incorrect value for PRINT_EXTRACT. name found<br />

while only NOMINAL, NOMLAST, ALL and numbers are allowed<br />