Examples<br />

Tutorial—High Impedance Fault Detection of a PLL Circuit<br />

Observe the impedance of the charge pump output (in green). It goes into high<br />

impedance state only when the charge pump input ports (UP in blue and DOWN in<br />

yellow) are equal to zero.<br />

The circuit schematic for the charge pump (highlighted in yellow) is shown below:<br />

When UP=DOWN=0, both transistors M2R and M1R are turned OFF and therefore<br />

their common node INVCO goes into high impedance state. This is the expected<br />

behavior.<br />