Simulation Results<br />

Examples<br />

Example 19—DC Mismatch Comparison with Monte Carlo Analysis<br />

Figure 21-30. Example 19—Simulation Results<br />

Results Comparison<br />

The extracted information from the DCMISMATCH results are as follows:<br />

* OFFSET = -3.5800E-04 Volts<br />

* POWER = 8.7764E-05 Watt<br />

* DCM_OFFSET = 6.0338E-03 Volts<br />

* DCM_POWER = 1.2859E-06<br />

The extracted information from the Monte Carlo results are as follows:<br />

* MC_OFFSET = 6.0033E-03<br />

* MC_POWER = 1.2706E-06<br />

Comparing the results shows the DCMISMATCH analysis and equivalent Monte Carlo analysis<br />

generate similar offset and power results.<br />

DCMISMATCH Results<br />

The full DCMISMATCH results are as follows:<br />