10.06.2016 Views

eldo_user

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Examples<br />

Example 17—Monte Carlo Sensitivity of a Two-Stage Operational Amplifier<br />

• .MC—Monte Carlo analysis.<br />

• .EXTRACT—Extract characteristics from the simulator results.<br />

• .PLOT—Plot simulator results.<br />

Netlist Explanation<br />

.EXTRACT AC LABEL=MAX MAX(VDB(OUT))<br />

.EXTRACT AC LABEL=BW 'CROSSING(VDB(OUT), -3) / 10E6'<br />

.PLOT AC VDB(OUT)<br />

.EXTRACT DC LABEL=IVDD I(VDD)<br />

The above lines specify the outputs. The output metrics are the maximum value of the closed<br />

loop response, the -3dB bandwidth, and the power consumption. The Monte Carlo sensitivity<br />

analysis enables understanding which statistical parameters are impacting these output<br />

quantities, and which ones are not. The different metrics are not necessarily affected by the<br />

same statistical variables, so Eldo provides one table per metric.<br />

.MC 1000<br />

The Monte Carlo analysis is run with NRUN=1000 to obtain very accurate estimations of the<br />

sensitivity indices Si. Results are extracted for the IVDD extract.<br />

1310<br />

Eldo® User's Manual, 15.3