Summary of Eldo commands used in this example:<br />

• .MODEL—Model definition.<br />

• .TRAN—Transient analysis.<br />

• .PLOT—Plot simulator results.<br />

Netlist Explanation<br />

.MODEL M3 NMOS LEVEL=3 VTO=0.25V TOX=2.5N UO=600<br />

Examples<br />

Example 14—Charge Conservation in MOS Models<br />

The above line describes the electrical parameters of the nmos model M3. This is an old level 3<br />

model that does not conserve charge properly.<br />

.MODEL M53 NMOS LEVEL=53 VTH0=0.25V TOX=2.5N U0=600<br />

The above line describes the electrical parameters of the nmos model M53. This is a BSIM3<br />

model, that conserves charge.<br />

Simulation Results<br />

In the simulation waveforms in Figure 21-25, V(3) is the result of the charge control model and<br />

V(1) is the result of the capacitive model. For V(1) the error on the charge is accumulated and<br />

error is increasing at each period. However, for V(3) there is no error on the charges.<br />