Example 6—Transient Analysis of a High Voltage Cascade<br />

The above line defines the global parameters cap1 and cap2 that are used in the capacitor and<br />

diode definitions to be 1nF and 10nF respectively.<br />

.option reltol=0.01 vmax=100000 vmin=-100000<br />

The above line sets the relative accuracy to a value of 0.01 and output voltage limits between<br />

100,000 and -100,000V due to the high voltage levels present in this circuit.<br />

.tran 0.5m 5m<br />

The above line specifies that a transient analysis should be performed on the circuit lasting 5ms<br />

with a plotting increment for the line printer of 0.5ms.<br />

.plot tran v(5)<br />

.plot tran v(1)<br />

The above lines specify voltage/time plots to be performed on separate graphs of the voltages at<br />

nodes 5 and 1.<br />