Eldo Control Language<br />

Simulation Dynamic Control<br />

frequency[ 9] = 7.538e+06 Hz<br />

frequency[10] = 7.428e+06 Hz<br />

frequency[11] = 7.107e+06 Hz<br />

frequency[12] = 7.046e+06 Hz<br />

frequency[13] = 7.021e+06 Hz<br />

frequency[14] = 7.010e+06 Hz<br />

frequency[15] = 7.004e+06 Hz<br />

frequency[16] = 7.001e+06 Hz<br />

frequency[17] = 7.000e+06 Hz<br />

Frequency stabilized at 7.000e+06 Hz at t=2.32e-06 s.<br />

***** Simulation succeeded<br />

Callback Arguments<br />

The callback function can have input and output arguments. The way to set them is quite<br />

natural: the expression assigned to the “callback” argument of the simulation function is the<br />

expression evaluated when the callback function will be automatically executed.<br />

Example 1<br />

The values of some variables are passed from the main task to the callback:<br />

Eldo® User's Manual, 15.3 1021