Lika Electronic incremental and absolute linear encoders catalogue 2016 in English Our new linear encoders catalogue is out now, and features many innovative new products and up-to-date information. The catalogue is expressly designed to set out the comprehensive range of incremental & absolute linear encoders from Lika Electronic. Check it out, it is completely renewed! Make sure you don’t miss out on a copy, download the pdf file from our web site or request your hard copy now! We have also got an interactive digital version in the works that shall be released soon!

Lika Electronic incremental and absolute linear encoders catalogue 2016 in English
Our new linear encoders catalogue is out now, and features many innovative new products and up-to-date information. The catalogue is expressly designed to set out the comprehensive range of incremental & absolute linear encoders from Lika Electronic. Check it out, it is completely renewed!
Make sure you don’t miss out on a copy, download the pdf file from our web site or request your hard copy now!
We have also got an interactive digital version in the works that shall be released soon!

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>LINEPULS</strong> • <strong>LINECOD</strong><br />

Technical <strong>in</strong>formation<br />

www.lika.biz<br />

The IP69K protection rate is not def<strong>in</strong>ed <strong>in</strong> the <strong>in</strong>ternational standard IEC 60529 but <strong>in</strong> the<br />

German standard DIN 40050-9 which was orig<strong>in</strong>ally <strong>in</strong>tended to concern the road vehicles<br />

and nowadays is generally and widely considered as an <strong>in</strong>tegration of the IEC 60529 rat<strong>in</strong>g<br />

system. The IP69K protection rate applies to equipment able to withstand high-pressure and<br />

high-temperature wash down and even steam clean<strong>in</strong>g applications.<br />

Selected products with IP69K protection rate are available on request.<br />

IP69K<br />

The United States National Electrical Manufacturers Association (NEMA) also publishes<br />

protection rat<strong>in</strong>gs for enclosures similar to the IP rat<strong>in</strong>g system. However, it also dictates<br />

other product features not addressed by IP codes, such as corrosion resistance.<br />

Thus, while it is possible to map NEMA rat<strong>in</strong>gs that satisfy or exceed the IP code criteria, it<br />

is not possible to map IP codes to NEMA enclosure rat<strong>in</strong>gs, as the IP code does not mandate<br />

the additional requirements. The table below <strong>in</strong>dicates the m<strong>in</strong>imum NEMA rat<strong>in</strong>g that satisfies<br />

or exceeds a given IP code, but can only be used <strong>in</strong> that way, not to map IP to NEMA.<br />

NEMA rat<strong>in</strong>gs and IP equivalency<br />

chart<br />

NEMA enclosure rat<strong>in</strong>g IP Code<br />

1 IP10<br />

2 IP11<br />

3 IP54<br />

3R<br />

IP14<br />

3S<br />

IP54<br />

4 IP56<br />

4X<br />

IP56<br />

5 IP52<br />

6 IP67<br />

6P<br />

IP67<br />

12 and 12K IP52<br />

13 IP54<br />