OTHER PRODUCTS RADAR LOCATION AND AIR DEFENCE TYPE 60-II-40 HYDRAULIC FILTER Filter is designed for coolant purification from mechanical impurities in temperature range monitoring systems of radio electronic equipment. Main Specifications: Ambient temperature Degree of filtration Rated consumption from -60 to +80 o C 40 micron 60 L/min HYDRAULIC VALVE CONNECTORS Device is designed for connecting and disconnecting of pipelines in temperature range monitoring systems of radio electronic equipment. Main Specifications: 242 229 239 Nominal bore diameter 19,0 mm 19,0 mm 9,5 mm Rated consumption 100 L/min 100 L/min 10 L/min Operating pressure 20 kgf/sm 2 20 kgf/sm 2 20 kgf/sm 2 Ambient temperature from -60 to +85 o C 204

RADAR LOCATION AND AIR DEFENCE OTHER PRODUCTS PRESSURE INDICATOR 101, 111 Indicator is designed for coolant pressure monitoring in temperature range monitoring systems of radio electronic equipment. Main Specifications: Ambient temperature from -60 to +85 o C Actuating pressure from 0,04 to 0,15 kgf/sm 2 Actuating basic error ±5% Maximum operating pressure 0,4 SURFACE TEMPERATURE SENSOR 150 Sensor is designed to monitor the surface temperature in temperature range monitoring systems of radio electronic equipment. Main Specifications: Ambient temperature Adjustment range Basic actuating error Temperature differential Dead band from -65 to +85 o C from 0 to + 40 o C ±1,5 o C 0,5 o C not more than 2 o C TEMPERATURE ALARM 071-1 Designed for control and two-position adjustment of coolant temperature in temperature range monitoring systems of radio electronic equipment. Main Specifications: Ambient temperature Subband of temperature adjustment Temperature differential Basic error (at temperature change rate of liquid not more than 0,5°С/ min. and of air not more than 0,2°С/min. at normal conditions) from -60 to +80 o C from -60 to -45 o C 0,5 o C not more than ±1% 205

RADAR LOCATION AND AIR DEFENCE<br />

OTHER PRODUCTS<br />

PRESSURE INDICATOR 101, 111<br />

Indicator is designed for coolant<br />

pressure monitoring in temperature<br />

range monitoring systems of radio<br />

electronic equipment.<br />

Main Specifications:<br />

Ambient temperature<br />

from -60 to +85 o C<br />

Actuating pressure from 0,04 to 0,15 kgf/sm 2<br />

Actuating basic error ±5%<br />

Maximum operating pressure 0,4<br />

SURFACE TEMPERATURE SENSOR 150<br />

Sensor is designed to monitor the surface<br />

temperature in temperature range monitoring<br />

systems of radio electronic equipment.<br />

Main Specifications:<br />

Ambient temperature<br />

Adjustment range<br />

Basic actuating error<br />

Temperature differential<br />

Dead band<br />

from -65 to +85 o C<br />

from 0 to + 40 o C<br />

±1,5 o C<br />

0,5 o C<br />

not more than 2 o C<br />

TEMPERATURE ALARM 071-1<br />

Designed for control and two-position<br />

adjustment of coolant temperature in<br />

temperature range monitoring systems<br />

of radio electronic equipment.<br />

Main Specifications:<br />

Ambient temperature<br />

Subband of temperature adjustment<br />

Temperature differential<br />

Basic error (at temperature change rate of liquid not more than 0,5°С/<br />

min. and of air not more than 0,2°С/min. at normal conditions)<br />

from -60 to +80 o C<br />

from -60 to -45 o C<br />

0,5 o C<br />

not more than ±1%<br />