Q3. In reviewing the form QW-483 (PQR form) in a Code shop, the<br />

Authorized Inspector noticed the thickness of test coupon was<br />

documented as 3/4" SA-285C plate. However on the back of the form<br />

thickness of the specimen was recorded as 0.725". The difference in<br />

thickness is most likely because.<br />

(a) A mistake in the testing laboratory, they documented a different set of<br />

coupon on this PQR.<br />

(b) The thickness of the specimen is approximate.<br />

(c) The test coupon has been machined down to 0.725" to offset the heat<br />

distortion due to welding.<br />

ANS: c<br />

Q4. A welder was qualified by a plate at 4G (overhead) position in the lab. He<br />

will be qualified to weld pipe 2 7/8" O.D. and over, but under 24" O.D. in<br />

the field in the overhead position.<br />

(a) True<br />

(b) False<br />

ANS: b correct answer<br />