24.03.2016 Views

Understanding API ICP653 Reading 15-Worksheet-11a

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Q10. What dimensional requirement is there for the guided-bend test jig<br />

mandrel being used on specimens wider than 1-1/2"?<br />

(a) At least ½" wider than the specimen width ..<br />

(b) At least 1/8" wider than the specimen width.<br />

(c) At least 1/4 “ wider than the specimen width.<br />

ANS: c<br />

Q11. The substitution of radiography for mechanical testing is permitted for<br />

welder and welding operator performance qualifications except as restricted<br />

by QW-304 & 305.<br />

(a) True<br />

(b) False<br />

ANS: a<br />

Q12. At what base metal thickness shall the multiple turned tension<br />

specimens be used? The specimens are cut through the full thickness of the<br />

weld with their centers parallel to the metal surface and not over 1" apart.<br />

(a) 5/8"<br />

(b) > 1"<br />

(c)

Hooray! Your file is uploaded and ready to be published.