Q44. A repair organization has a WPS which states it is qualified far P-6 (Martensitic/Ferritic SS) to P-8 material (Austenitic SS) welded with either E308, E308L, E309, E316, electrodes (SMAW process). The PQR, supporting this WPS, states the weld test coupons were SA-240 Type 304L material (P8, γ SS), welded with E308 electrodes. Is the WPS properly qualified for the base material listed? A. Yes B. No C. Nat enough information given D. Yes, if properly heat treated ANS: b? P8-P8 coupons Charlie Chong/ Fion Zhang
QW-424 Base Metals Used for Procedure Qualification QW-424.1 Base metals are assigned P-Numbers in table QW/QB-422; Metals that do not appear in table QW/QB-422 are considered to be unassigned metals except as otherwise defined for base metals having the same UNS numbers. Unassigned metals shall be identified in the WPS and on the PQR by specification, type and grade, or by chemical analysis and mechanical properties. The minimum tensile strength shall be defined by the organization that specified the unassigned metal if the tensile strength of that metal is not defined by the material specification. Charlie Chong/ Fion Zhang
- Page 77 and 78: Q5. Why is the Manufacturer respons
- Page 79 and 80: Q9. When performance qualification
- Page 81 and 82: Q13. Failure of any portion of a co
- Page 83 and 84: Charlie Chong/ Fion Zhang #8
- Page 85 and 86: TASK#8 Welding Data QW-400 thru QW-
- Page 87 and 88: Q2. Under what conditions may a WPS
- Page 89 and 90: Q6. A change in a welding condition
- Page 91 and 92: Q8. The grouping of ____and____ by
- Page 93 and 94: Charlie Chong/ Fion Zhang #9
- Page 95 and 96: TASK#9 Welding Data QW-451 thru QW-
- Page 97 and 98: Q3. In reviewing the form QW-483 (P
- Page 99 and 100: Q5. The SAW process is commonly cla
- Page 101 and 102: ASME SECTION IX PRACTICE QUESTIONS
- Page 103 and 104: Q5. New Welding Procedure Specifica
- Page 105 and 106: Q9. A welder qualifying with plate
- Page 107 and 108: Q12. Charpy V-notch tests are perfo
- Page 109 and 110: Q17. A WPS must describe: A. Essent
- Page 111 and 112: Q21. For the SAW process ______ is
- Page 113 and 114: Q26. Immediate retests of welders q
- Page 115 and 116: QW-452 Performance Qualification Th
- Page 117 and 118: QW-430 F-NUMBERS QW-431 General The
- Page 119 and 120: Q32. Ferrous weld metal chemical co
- Page 121 and 122: Q36. What is the basic difference b
- Page 123 and 124: QW-304 Welders Except for the speci
- Page 125 and 126: Q40. Who is responsible for qualifi
- Page 127: Q44. A repair organization has a WP
- Page 131 and 132: Q45. What positions are necessary t
- Page 133 and 134: Q48. May a GMAW, short circuit tran
- Page 135 and 136: ESW Electroslag welding (ESW) is a
- Page 137 and 138: Charlie Chong/ Fion Zhang #11
- Page 139 and 140: Q54. A welder was qualified with a
- Page 141 and 142: Charlie Chong/ Fion Zhang
- Page 143 and 144: Q55. What are the primary classific
- Page 145 and 146: Q58. Applicable essential variables
- Page 147 and 148: Q62. The test that determines the u
- Page 149 and 150: Q66. A non-essential variable may b
- Page 151 and 152: Q71. Unless notch-toughness is a co
- Page 153 and 154: Q76. Variable QW 404.24 for SAW pro
- Page 155 and 156: Q81. A WPS must address all applica
- Page 157 and 158: Q86. A welder is qualified to weld
- Page 159 and 160: Q88. What period of inactivity from
- Page 161 and 162: Q92. Each manufacturer or contracto
- Page 163 and 164: Charlie Chong/ Fion Zhang
- Page 165 and 166: QW-405.3 A change from upward to do
- Page 167 and 168: 98. Under which of the following co
- Page 169 and 170: Charlie Chong/ Fion Zhang
- Page 171 and 172: Happy Holi Charlie Chong/ Fion Zhan
- Page 173 and 174: Happy Holi Charlie Chong/ Fion Zhan
- Page 175 and 176: Happy Holi Charlie Chong/ Fion Zhan
- Page 177 and 178: Charlie Chong/ Fion Zhang
Q44. A repair organization has a WPS which states it is qualified far P-6<br />
(Martensitic/Ferritic SS) to P-8 material (Austenitic SS) welded with either<br />
E308, E308L, E309, E316, electrodes (SMAW process).<br />
The PQR, supporting this WPS, states the weld test coupons were SA-240<br />
Type 304L material (P8, γ SS), welded with E308 electrodes. Is the WPS<br />
properly qualified for the base material listed?<br />
A. Yes<br />
B. No<br />
C. Nat enough information given<br />
D. Yes, if properly heat treated<br />
ANS: b? P8-P8 coupons<br />
Charlie Chong/ Fion Zhang