52 <strong>Centrifugal</strong> <strong>Pumps</strong>: <strong>Design</strong> <strong>and</strong> <strong>Application</strong><br />

Types of Volute <strong>Design</strong>s<br />

There are several different volute designs being manufactur<strong>ed</strong> today.<br />

Single-Volute Casing <strong>Design</strong>s<br />

Single-volute pumps have been in existence from Day thie. <strong>Pumps</strong> design<strong>ed</strong><br />

using single-volute casings of constant velocity design are more<br />

efficient than those using more complicat<strong>ed</strong> volute designs. They are also<br />

less difficult to cast <strong>and</strong> more economical to produce because of the open<br />

areas around impeller periphery. Theoretically they can be us<strong>ed</strong> on large<br />

as well as small pumps of all specific spe<strong>ed</strong>s. Stepanoff gives a complete<br />

description of single-volute casing design.<br />

In all volute pumps the pressure distribution around the periphery of<br />

the impeller is uniform only at the BEP. This pressure equilibrium is destroy<strong>ed</strong><br />

when the pump is operating on either side of the BEP, resulting in<br />

a radial load on the impeller. This load deflects the pump shaft <strong>and</strong> can<br />

result in excessive wear at the wearing rings, seals, packing, or bearings,<br />

In extreme cases, shaft breakage due to fatigue failure can result. The<br />

magnitude of this radial load is given by:<br />

P = KHD 2 B 2 spgr/2.31<br />

<strong>Val</strong>ues of the experimental constant K are given in Figure 5-2. For a<br />

specific single-volute pump it reaches its maximum at shutoff <strong>and</strong> will<br />

vary between 0.09 <strong>and</strong> 0.38 depending upon specific spe<strong>ed</strong>. The effect of<br />

the force will be most pronounc<strong>ed</strong> on a single-stage pump with a wide b 2<br />

or a large-siz<strong>ed</strong> pump.<br />

It is safe to say that with existing design techniques, single-volute designs<br />

are us<strong>ed</strong> mainly on low capacity, low specific spe<strong>ed</strong> pumps or<br />

pumps for special applications such as variable slurries or solids h<strong>and</strong>ling.<br />

Double-Volute Casing <strong>Design</strong>s<br />

A double-volute casing design is actually two single-volute designs<br />

combin<strong>ed</strong> in an oppos<strong>ed</strong> arrangement. The total throat area of the two<br />

volutes is identical to that which would be us<strong>ed</strong> on a comparable singlevolute<br />

design.<br />

Double-volute casings were introduc<strong>ed</strong> to eliminate the radial thrust<br />

problems that are inherent in single-volute designs. Test measurements,<br />

however, indicate that while the radial forces in a double volute are<br />

greatly r<strong>ed</strong>uc<strong>ed</strong>, they are not completely eliminat<strong>ed</strong>. This is because al~