38 <strong>Centrifugal</strong> <strong>Pumps</strong>: <strong>Design</strong> <strong>and</strong> <strong>Application</strong><br />

Figure 3-9. Impeller layout.<br />

suction entrance angles to establish match between discharge angle <strong>and</strong><br />

suction angles. Once a match is establish<strong>ed</strong> with a smooth curve, lay out<br />

the remaining vane points until the eye diameter is reach<strong>ed</strong>, in this case at<br />

Point 10.<br />

Figure 3-10. Impeller inlet velocity triangle.