22 <strong>Centrifugal</strong> <strong>Pumps</strong>: <strong>Design</strong> <strong>and</strong> <strong>Application</strong><br />

Qm<br />

0<br />

100<br />

200<br />

300<br />

400<br />

500<br />

600<br />

650<br />

Table 2-5<br />

Tabulat<strong>ed</strong> Performance of Model Pump<br />

(Model 9-1 n. Diameter Impeller)<br />

H m<br />

350<br />

349<br />

345<br />

337<br />

325<br />

300<br />

260<br />

235<br />

Eff. m %<br />

0<br />

28<br />

48<br />

52<br />

70<br />

74<br />

73<br />

72<br />

Wlp m<br />

25<br />

31<br />

36<br />

42<br />

46<br />

57<br />

54<br />

54<br />

Q,<br />

0<br />

!40<br />

280<br />

420<br />

560<br />

700<br />

840<br />

910<br />

Table 2-6<br />

Tabulat<strong>ed</strong> Performance of New Pump<br />

(New Pump 10 1 /a-ln. Diameter Impeller)<br />

H,<br />

437<br />

436<br />

431<br />

421<br />

406<br />

375<br />

325<br />

293<br />

Eff.i %<br />

0<br />

28<br />

49<br />

53<br />

71<br />

75<br />

74<br />

72<br />

bhpi<br />

50<br />

55<br />

62<br />

84<br />

81<br />

88<br />

93<br />

94<br />

Applying these factors to the model, the new pump performance at<br />

BEP will be: 700 GPM; 375 ft; 75% efficiency; 94 maximum HP; 3,550<br />

RPM; <strong>and</strong> lOVs-in. impeller diameter.<br />

To obtain complete H-Q performance refer to Tables 2-5 <strong>and</strong> 2-6.<br />

The new pump size will be a 4-in. x 6-in. x 10-in. with performance<br />

as shown in Figure 2-7.<br />

All major pump manufacturers have in their files records of pump performance<br />

tests covering a wide range of specific spe<strong>ed</strong>s. Each test can be<br />

us<strong>ed</strong> as a model to pr<strong>ed</strong>ict new pump performance <strong>and</strong> to design same. In<br />

the majority of cases, the requir<strong>ed</strong> model specific spe<strong>ed</strong> can be found<br />

having the same running spe<strong>ed</strong> as requir<strong>ed</strong> by the new pump. There are<br />

cases, however, where the model pump running spe<strong>ed</strong> is different than<br />

requir<strong>ed</strong> by pump in question.