Chemical <strong>Pumps</strong> Metallic <strong>and</strong> Nonmetallic 323<br />

The pump shaft is connect<strong>ed</strong> directly to the motor by a rigid adjustable<br />

coupling, <strong>and</strong> in-line motors are us<strong>ed</strong> to absorb the axial thrust. If a nor<br />

mal thrust motor is us<strong>ed</strong>, then a separate thrust bearing is us<strong>ed</strong> within the<br />

support head to absorb the axial thrust.<br />

Level Controls<br />

With chemical sump pumps, the level control is usually encas<strong>ed</strong> to prevent<br />

the fluid from coming in direct contact with the switching mechanism.<br />

Stilling Tubes<br />

If it is anticipat<strong>ed</strong> that swirl or vortexing will exist within the sump, the<br />

level controls are mount<strong>ed</strong> within a stilling tube that indicates the true<br />

level of the liquid within the sump.<br />

Mounting Plates <strong>and</strong> Pit Covers<br />

These plates are made out of the same base material as the pumps. Depending<br />

on the size, the pit covers may require reinforcement of steel<br />

angles or channels. These steel pieces are encapsulat<strong>ed</strong> so they are not<br />

expos<strong>ed</strong> to the atmosphere.<br />

Processes<br />

Chemical pumps h<strong>and</strong>le a variety of liquids that could be concentrat<strong>ed</strong>,<br />

dilut<strong>ed</strong>, or just a trace. The concentration could be from 5% to 50% or<br />

the liquid could be in parts per million. Temperature could be hot or cold,<br />

<strong>and</strong> a pump can be sold to h<strong>and</strong>le maximum, minimum, or normal temperature.<br />

The range of temperature could cause thermal shock <strong>and</strong> can<br />

vary as much as 150°F from the cold to hot application. The rate of activity<br />

of the fluid changes approximately two to three times for each 18°F<br />

change in temperature. The liquids could have either an alkaline or acidic<br />

pH level. Liquids may contain solids that might cause erosion, corrosion,<br />

or settling problems that would result in clogging. The liquid may have<br />

entrain<strong>ed</strong> air that would make a r<strong>ed</strong>ucing solution into oxidation or it<br />

could have inhibitors to r<strong>ed</strong>uce corrosion or accelerators to increase corrosion.<br />

The impurities could lead to something call<strong>ed</strong> discoloration or solution<br />

breakdown.<br />

Final pump material selection is a collective decision bas<strong>ed</strong> on input<br />

from the pump designer, plant operator, material supplier, <strong>and</strong> available<br />

technical literature.