SINGLE LAYER CONSTRUCTION<br />

TRACK - CUT AND<br />

BENT DOWN<br />

FASTEN JAMB STUDS TO TRACK<br />

TOP AND BOTTOM<br />

JAMB<br />

ANCHORS<br />

92 NATIONAL GYPSUM BOARD PRODUCTS<br />

C.R. CHANNEL<br />

STIFFENERS<br />

FRICTION FIT<br />

(OPTIONAL)<br />

STEEL DOOR<br />

FRAME<br />

FRAMING REQUIREMENTS AT DOORS<br />

(Type of Door Frame) (Special Details) Partition Height Limits*<br />

Jamb Steel Studs Knock Knock Bracing Requires Stud Size<br />

Door Min. Down Down Fixed Over Mechanical 1 5/8" 2 1/2" 3 5/8" 4" 6"<br />

Weight Base Steel, In. Alum. Steel Steel Headers Closure (41.3mm) (63.5mm) (92.1mm) (102mm) (152mm)<br />

Up to<br />

50 lbs.<br />

(23 kg)<br />

50 lbs.<br />

(23 kg) to<br />

80 lbs.<br />

(36 kg)<br />

80 lbs.<br />

(36 kg) to<br />

120 lbs.<br />

(54 kg)<br />

16' MAX. HEIGHT<br />

20" MAX. WIDTH<br />

PER ASTM C754<br />

CHASE WALL<br />

0.0179<br />

0.0179<br />

x<br />

x<br />

x<br />

x<br />

x<br />

x x<br />

NA**<br />

10'(3048mm)<br />

10'(3048mm)<br />

12'(3657mm)<br />

14'(4267mm)<br />

16'(4876mm)<br />

15'(4572mm)<br />

17'(5181mm)<br />

14'(4267mm)<br />

16'(4876mm)<br />

0.0329 x x x x – 16'(4876mm) 21'(6400mm) 22'(6705mm) 22'(6705mm)<br />

0.0179<br />

0.0179<br />

0.0179<br />

x<br />

x x<br />

x<br />

x<br />

x<br />

x<br />

x<br />

x<br />

–<br />

10'(3048mm)<br />

12'(3657mm)<br />

10'(3048mm)<br />

12'(3657mm)<br />

14'(4267mm)<br />

14'(4267mm)<br />

14'(4267mm)<br />

16'(4876mm)<br />

15'(4572mm)<br />

15'(4572mm)<br />

17'(5181mm)<br />

14'(4267mm)<br />

14'(4267mm)<br />

16'(4876mm)<br />

0.0329 x 10'(3048mm) 14'(4267mm) 15'(4572mm) 15'(4572mm)<br />

0.0329 x x x 12'(3657mm) 16'(4876mm) 17'(5181mm) 17'(5181mm)<br />

0.0329 x x x 12'(3657mm) 16'(4876mm) 17'(5181mm) 17'(5181mm)<br />

0.0329 dbl. web to web x 16'(4876mm) 21'(6400mm) 22'(6705mm) 22'(6705mm)<br />

0.0329 dbl. web to web x x 16'(4876mm) 21'(6400mm) 22'(6705mm) 22'(6705mm)<br />

0.0179 x x x 12'(3657mm) 14'(4267mm) 15'(4572mm) 14'(4267mm)<br />

0.0329 x x x x 12'(3657mm) 16'(4876mm) 17'(5181mm) 17'(5181mm)<br />

0.0329 dbl. web to web x x 16'(4876mm) 21'(6400mm) 22'(6705mm) 22'(6705mm)<br />

* For a specific partition having a door opening compare above partition height limits with height tables on page 88. The lower height table governs.<br />

** NA – Not Allowed.<br />

12"<br />

48"<br />

MAX.<br />

STEEL TRACK<br />

TAPE AND JOINT<br />

COMPOUND<br />

FACE GYPSUM BOARD (APPLIED<br />

IN NORMAL MANNER)<br />

1/2" GYPSUM<br />

BOARD OR<br />

STUD TRACK<br />

2 SCREWS<br />

PER STUD<br />

(ALTERNATE)<br />

3 DRYWALL<br />

SCREWS<br />

PER STUD