SINGLE LAYER CONSTRUCTION<br />
TRACK - CUT AND<br />
BENT DOWN<br />
FASTEN JAMB STUDS TO TRACK<br />
TOP AND BOTTOM<br />
JAMB<br />
ANCHORS<br />
92 NATIONAL GYPSUM BOARD PRODUCTS<br />
C.R. CHANNEL<br />
STIFFENERS<br />
FRICTION FIT<br />
(OPTIONAL)<br />
STEEL DOOR<br />
FRAME<br />
FRAMING REQUIREMENTS AT DOORS<br />
(Type of Door Frame) (Special Details) Partition Height Limits*<br />
Jamb Steel Studs Knock Knock Bracing Requires Stud Size<br />
Door Min. Down Down Fixed Over Mechanical 1 5/8" 2 1/2" 3 5/8" 4" 6"<br />
Weight Base Steel, In. Alum. Steel Steel Headers Closure (41.3mm) (63.5mm) (92.1mm) (102mm) (152mm)<br />
Up to<br />
50 lbs.<br />
(23 kg)<br />
50 lbs.<br />
(23 kg) to<br />
80 lbs.<br />
(36 kg)<br />
80 lbs.<br />
(36 kg) to<br />
120 lbs.<br />
(54 kg)<br />
16' MAX. HEIGHT<br />
20" MAX. WIDTH<br />
PER ASTM C754<br />
CHASE WALL<br />
0.0179<br />
0.0179<br />
x<br />
x<br />
x<br />
x<br />
x<br />
x x<br />
NA**<br />
10'(3048mm)<br />
10'(3048mm)<br />
12'(3657mm)<br />
14'(4267mm)<br />
16'(4876mm)<br />
15'(4572mm)<br />
17'(5181mm)<br />
14'(4267mm)<br />
16'(4876mm)<br />
0.0329 x x x x – 16'(4876mm) 21'(6400mm) 22'(6705mm) 22'(6705mm)<br />
0.0179<br />
0.0179<br />
0.0179<br />
x<br />
x x<br />
x<br />
x<br />
x<br />
x<br />
x<br />
x<br />
–<br />
10'(3048mm)<br />
12'(3657mm)<br />
10'(3048mm)<br />
12'(3657mm)<br />
14'(4267mm)<br />
14'(4267mm)<br />
14'(4267mm)<br />
16'(4876mm)<br />
15'(4572mm)<br />
15'(4572mm)<br />
17'(5181mm)<br />
14'(4267mm)<br />
14'(4267mm)<br />
16'(4876mm)<br />
0.0329 x 10'(3048mm) 14'(4267mm) 15'(4572mm) 15'(4572mm)<br />
0.0329 x x x 12'(3657mm) 16'(4876mm) 17'(5181mm) 17'(5181mm)<br />
0.0329 x x x 12'(3657mm) 16'(4876mm) 17'(5181mm) 17'(5181mm)<br />
0.0329 dbl. web to web x 16'(4876mm) 21'(6400mm) 22'(6705mm) 22'(6705mm)<br />
0.0329 dbl. web to web x x 16'(4876mm) 21'(6400mm) 22'(6705mm) 22'(6705mm)<br />
0.0179 x x x 12'(3657mm) 14'(4267mm) 15'(4572mm) 14'(4267mm)<br />
0.0329 x x x x 12'(3657mm) 16'(4876mm) 17'(5181mm) 17'(5181mm)<br />
0.0329 dbl. web to web x x 16'(4876mm) 21'(6400mm) 22'(6705mm) 22'(6705mm)<br />
* For a specific partition having a door opening compare above partition height limits with height tables on page 88. The lower height table governs.<br />
** NA – Not Allowed.<br />
12"<br />
48"<br />
MAX.<br />
STEEL TRACK<br />
TAPE AND JOINT<br />
COMPOUND<br />
FACE GYPSUM BOARD (APPLIED<br />
IN NORMAL MANNER)<br />
1/2" GYPSUM<br />
BOARD OR<br />
STUD TRACK<br />
2 SCREWS<br />
PER STUD<br />
(ALTERNATE)<br />
3 DRYWALL<br />
SCREWS<br />
PER STUD