The MOSEK command line tool Version 7.0 (Revision 141)

The MOSEK command line tool. Version 7.0 ... - Documentation The MOSEK command line tool. Version 7.0 ... - Documentation

25.11.2015 Views

78 CHAPTER 8. SENSITIVITY ANALYSIS 5 c6 FIX -5.000000e+02 6.574875e-18 3.000000e+00 3.000000e+00 BOUNDS VARIABLES INDEX NAME BOUND LEFTRANGE RIGHTRANGE LEFTPRICE RIGHTPRICE 2 x23 LO -6.574875e-18 5.000000e+02 2.000000e+00 2.000000e+00 3 x24 LO -inf 5.000000e+02 0.000000e+00 0.000000e+00 4 x31 LO -inf 5.000000e+02 0.000000e+00 0.000000e+00 0 x11 LO -inf 3.000000e+02 0.000000e+00 0.000000e+00 OBJECTIVE VARIABLES INDEX NAME LEFTRANGE RIGHTRANGE LEFTPRICE RIGHTPRICE 0 x11 -inf 1.000000e+00 3.000000e+02 3.000000e+02 2 x23 -2.000000e+00 +inf 0.000000e+00 0.000000e+00 8.5.3 Controlling log output Setting the parameter MSK IPAR LOG SENSITIVITY to 1 or 0 (default) controls whether or not the results from sensitivity calculations are printed to the message stream. The parameter MSK IPAR LOG SENSITIVITY OPT controls the amount of debug information on internal calculations from the sensitivity analysis.

Chapter 9 Parameters Parameters grouped by functionality. Analysis parameters. Parameters controling the behaviour of the problem and solution analyzers. • MSK DPAR ANA SOL INFEAS TOL. If a constraint violates its bound with an amount larger than this value, the constraint name, index and violation will be printed by the solution analyzer. Basis identification parameters. • MSK IPAR BI CLEAN OPTIMIZER. Controls which simplex optimizer is used in the clean-up phase. • MSK IPAR BI IGNORE MAX ITER. Turns on basis identification in case the interior-point optimizer is terminated due to maximum number of iterations. • MSK IPAR BI IGNORE NUM ERROR. Turns on basis identification in case the interior-point optimizer is terminated due to a numerical problem. • MSK IPAR BI MAX ITERATIONS. Maximum number of iterations after basis identification. • MSK IPAR INTPNT BASIS. Controls whether basis identification is performed. • MSK IPAR LOG BI. Controls the amount of output printed by the basis identification procedure. A higher level implies that more information is logged. • MSK IPAR LOG BI FREQ. Controls the logging frequency. • MSK DPAR SIM LU TOL REL PIV. Relative pivot tolerance employed when computing the LU factorization of the basis matrix. Behavior of the optimization task. Parameters defining the behavior of an optimization task when loading data. • MSK SPAR FEASREPAIR NAME PREFIX. Feasibility repair name prefix. 79

78 CHAPTER 8. SENSITIVITY ANALYSIS<br />

5 c6 FIX -5.000000e+02 6.574875e-18 3.000000e+00 3.000000e+00<br />

BOUNDS VARIABLES<br />

INDEX NAME BOUND LEFTRANGE RIGHTRANGE LEFTPRICE RIGHTPRICE<br />

2 x23 LO -6.574875e-18 5.000000e+02 2.000000e+00 2.000000e+00<br />

3 x24 LO -inf 5.000000e+02 0.000000e+00 0.000000e+00<br />

4 x31 LO -inf 5.000000e+02 0.000000e+00 0.000000e+00<br />

0 x11 LO -inf 3.000000e+02 0.000000e+00 0.000000e+00<br />

OBJECTIVE VARIABLES<br />

INDEX NAME LEFTRANGE RIGHTRANGE LEFTPRICE RIGHTPRICE<br />

0 x11 -inf 1.000000e+00 3.000000e+02 3.000000e+02<br />

2 x23 -2.000000e+00 +inf 0.000000e+00 0.000000e+00<br />

8.5.3 Controlling log output<br />

Setting the parameter<br />

MSK IPAR LOG SENSITIVITY<br />

to 1 or 0 (default) controls whether or not the results from sensitivity calculations are printed to the<br />

message stream.<br />

<strong>The</strong> parameter<br />

MSK IPAR LOG SENSITIVITY OPT<br />

controls the amount of debug information on internal calculations from the sensitivity analysis.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!