The MOSEK command line tool Version 7.0 (Revision 141)
The MOSEK command line tool. Version 7.0 ... - Documentation The MOSEK command line tool. Version 7.0 ... - Documentation
168 CHAPTER 9. PARAMETERS Possible values: • MSK OFF Switch the option off. • MSK ON Switch the option on. Default value: MSK ON 9.2.134 MSK IPAR READ MPS OBJ SENSE Corresponding constant: MSK IPAR READ MPS OBJ SENSE Description: If turned on, the MPS reader uses the objective sense section. Otherwise the MPS reader ignores it. Possible values: • MSK OFF Switch the option off. • MSK ON Switch the option on. Default value: MSK ON 9.2.135 MSK IPAR READ MPS RELAX Corresponding constant: MSK IPAR READ MPS RELAX Description: If this option is turned on, then mixed integer constraints are ignored when a problem is read. Possible values: • MSK OFF Switch the option off. • MSK ON Switch the option on. Default value: MSK ON
9.2. MSKIPARAME: INTEGER PARAMETERS 169 9.2.136 MSK IPAR READ MPS WIDTH Corresponding constant: MSK IPAR READ MPS WIDTH Description: Controls the maximal number of characters allowed in one line of the MPS file. Possible Values: Any positive number greater than 80. Default value: 1024 9.2.137 MSK IPAR READ QNZ Corresponding constant: MSK IPAR READ QNZ Description: Expected maximum number of Q non-zeros to be read. The option is used only by MPS and LP file readers. Possible Values: Any number between 0 and +inf. Default value: 20000 9.2.138 MSK IPAR READ TASK IGNORE PARAM Corresponding constant: MSK IPAR READ TASK IGNORE PARAM Description: Controls whether MOSEK should ignore the parameter setting defined in the task file and use the default parameter setting instead. Possible values: • MSK OFF Switch the option off. • MSK ON Switch the option on. Default value: MSK OFF
- Page 133 and 134: 9.2. MSKIPARAME: INTEGER PARAMETERS
- Page 135 and 136: 9.2. MSKIPARAME: INTEGER PARAMETERS
- Page 137 and 138: 9.2. MSKIPARAME: INTEGER PARAMETERS
- Page 139 and 140: 9.2. MSKIPARAME: INTEGER PARAMETERS
- Page 141 and 142: 9.2. MSKIPARAME: INTEGER PARAMETERS
- Page 143 and 144: 9.2. MSKIPARAME: INTEGER PARAMETERS
- Page 145 and 146: 9.2. MSKIPARAME: INTEGER PARAMETERS
- Page 147 and 148: 9.2. MSKIPARAME: INTEGER PARAMETERS
- Page 149 and 150: 9.2. MSKIPARAME: INTEGER PARAMETERS
- Page 151 and 152: 9.2. MSKIPARAME: INTEGER PARAMETERS
- Page 153 and 154: 9.2. MSKIPARAME: INTEGER PARAMETERS
- Page 155 and 156: 9.2. MSKIPARAME: INTEGER PARAMETERS
- Page 157 and 158: 9.2. MSKIPARAME: INTEGER PARAMETERS
- Page 159 and 160: 9.2. MSKIPARAME: INTEGER PARAMETERS
- Page 161 and 162: 9.2. MSKIPARAME: INTEGER PARAMETERS
- Page 163 and 164: 9.2. MSKIPARAME: INTEGER PARAMETERS
- Page 165 and 166: 9.2. MSKIPARAME: INTEGER PARAMETERS
- Page 167 and 168: 9.2. MSKIPARAME: INTEGER PARAMETERS
- Page 169 and 170: 9.2. MSKIPARAME: INTEGER PARAMETERS
- Page 171 and 172: 9.2. MSKIPARAME: INTEGER PARAMETERS
- Page 173 and 174: 9.2. MSKIPARAME: INTEGER PARAMETERS
- Page 175 and 176: 9.2. MSKIPARAME: INTEGER PARAMETERS
- Page 177 and 178: 9.2. MSKIPARAME: INTEGER PARAMETERS
- Page 179 and 180: 9.2. MSKIPARAME: INTEGER PARAMETERS
- Page 181 and 182: 9.2. MSKIPARAME: INTEGER PARAMETERS
- Page 183: 9.2. MSKIPARAME: INTEGER PARAMETERS
- Page 187 and 188: 9.2. MSKIPARAME: INTEGER PARAMETERS
- Page 189 and 190: 9.2. MSKIPARAME: INTEGER PARAMETERS
- Page 191 and 192: 9.2. MSKIPARAME: INTEGER PARAMETERS
- Page 193 and 194: 9.2. MSKIPARAME: INTEGER PARAMETERS
- Page 195 and 196: 9.2. MSKIPARAME: INTEGER PARAMETERS
- Page 197 and 198: 9.2. MSKIPARAME: INTEGER PARAMETERS
- Page 199 and 200: 9.2. MSKIPARAME: INTEGER PARAMETERS
- Page 201 and 202: 9.2. MSKIPARAME: INTEGER PARAMETERS
- Page 203 and 204: 9.2. MSKIPARAME: INTEGER PARAMETERS
- Page 205 and 206: 9.2. MSKIPARAME: INTEGER PARAMETERS
- Page 207 and 208: 9.2. MSKIPARAME: INTEGER PARAMETERS
- Page 209 and 210: 9.2. MSKIPARAME: INTEGER PARAMETERS
- Page 211 and 212: 9.3. MSKSPARAME: STRING PARAMETER T
- Page 213 and 214: 9.3. MSKSPARAME: STRING PARAMETER T
- Page 215 and 216: 9.3. MSKSPARAME: STRING PARAMETER T
- Page 217 and 218: 9.3. MSKSPARAME: STRING PARAMETER T
- Page 219 and 220: Chapter 10 Response codes Response
- Page 221 and 222: 205 MSK RES ERR CON Q NOT PSD The q
- Page 223 and 224: 207 MSK RES ERR GLOBAL INV CONIC PR
- Page 225 and 226: 209 MSK RES ERR INV MARKJ Invalid v
- Page 227 and 228: 211 MSK RES ERR INVALID FORMAT TYPE
- Page 229 and 230: 213 MSK RES ERR LICENSE NO SERVER S
- Page 231 and 232: 215 MSK RES ERR MIO NO OPTIMIZER No
- Page 233 and 234: 217 MSK RES ERR NAME MAX LEN A name
9.2. MSKIPARAME: INTEGER PARAMETERS 169<br />
9.2.136 MSK IPAR READ MPS WIDTH<br />
Corresponding constant:<br />
MSK IPAR READ MPS WIDTH<br />
Description:<br />
Controls the maximal number of characters allowed in one <strong>line</strong> of the MPS file.<br />
Possible Values:<br />
Any positive number greater than 80.<br />
Default value:<br />
1024<br />
9.2.137 MSK IPAR READ QNZ<br />
Corresponding constant:<br />
MSK IPAR READ QNZ<br />
Description:<br />
Expected maximum number of Q non-zeros to be read. <strong>The</strong> option is used only by MPS and LP<br />
file readers.<br />
Possible Values:<br />
Any number between 0 and +inf.<br />
Default value:<br />
20000<br />
9.2.138 MSK IPAR READ TASK IGNORE PARAM<br />
Corresponding constant:<br />
MSK IPAR READ TASK IGNORE PARAM<br />
Description:<br />
Controls whether <strong>MOSEK</strong> should ignore the parameter setting defined in the task file and use<br />
the default parameter setting instead.<br />
Possible values:<br />
• MSK OFF Switch the option off.<br />
• MSK ON Switch the option on.<br />
Default value:<br />
MSK OFF